• Title/Summary/Keyword: End_to-end Test

Search Result 2,911, Processing Time 0.027 seconds

Structural Behavior Evaluation of Mg-GFRP Composite Single-Lap Bonded Joints With Different End Shapes (한 끝단 형상에 따른 마그네슘 합금과 유리섬유 복합소재 단일겹치기 본드 조인트 거동 분석)

  • Kim, Jung-Seok;Im, Jae-Young;Lee, Woo-Geun
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.6
    • /
    • pp.391-396
    • /
    • 2014
  • In this study, the strength of magnesium-GFRP/epoxy single-lap bonded joints are experimentally evaluated with different end shapes. In order to achieve this, four different single-lap joints with different end shapes are fabricated and the failure load is measured under tensile loading tests. From the test results, the single-lap joint with a square end exhibits the lowest failure load while the single-lap joint with reverse tapering and a spew fillet has the highest stress values. It has 11.1% higher failure strength than the single-lap joint with a square end.

End Stage Ankle Arthritis with Ankle Instability Patients Treatment Results Using Autograft Ligament Reconstruction with Total Ankle Arthroplasty (인대 불안정성이 동반된 말기 족근 관절염 환자의 자가 인대 재건술과 인공관절 치환술의 치료 결과)

  • Choi, Jae-Hyuck;Kim, Jeong-Ryoul;Kim, Dong-Hyun;Chung, Woo-Chull;Yoon, Jung-Ro;Yeo, Eui-Dong;Lee, Kyung-Tai
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • Purpose: We report the clinical and radiographic result of ligament reconstruction using plantaris and total ankle replacement in end-stage ankle arthritis with ankle instability. Materials and Methods: The study is based on the 9 cases among total 48 patients of end-stage ankle arthritis that were treated with total ankle prosthesis and ligament reconstruction from 2007 to 2009 at least 12 months follow-up. We evaluated the VAS (Visual analogue scale) pain score, AOFAS (American orthopedic foot and ankle society) score and radiographic measurements. Results: Average age was 59.4 years (53~67 years) old. VAS pain score improved from preoperative average $8.2{\pm}0.9$ (range, 7~10) to $2.7{\pm}1.7$ (range, 0~6) and the AOFAS score improved from $46.4{\pm}14.6$ points (range, 23~69) to $80.1{\pm}9.3$ points (range, 65~95) at final follow-up. Anterior draw test improved $15.2{\pm}3.4$ mm (range, 12~23 mm) to $8.8{\pm}2.6$ mm (range, 6~13mm), varus stress test improved from $13.9{\pm}4.6^{\circ}$ (range, $10-18^{\circ}$) to $6.2{\pm}4.7^{\circ}$ (range, $2-18^{\circ}$) at final follow up. Conclusion: Plantaris ligament reconstruction is good option as part of the management of ankle instability with end-stage ankle arthritis. We achieved good clinical and radiographic results.

Experimental investigation of force-distribution in high-strength bolts in extended end-plate connections

  • Abdalla, K.M.;Abu-Farsakh, G.A.R.;Barakat, S.A.
    • Steel and Composite Structures
    • /
    • v.7 no.2
    • /
    • pp.87-103
    • /
    • 2007
  • This paper presents some of the results from an experimental research project on the behavior of extended end-plate connections subjected to moment conducted at the Structural Laboratory of Jordan University of Science and Technology. Since the connection behavior affects the structural frame response, it must be included in the global analysis and design. In this study, the behavior of six full-scale stiffened and unstiffened cantilever connections of HEA- and IPE-sections has been investigated. Eight high strength bolts were used to connect the extended end-plate to the column flange in each case. Strain gauges were installed inside each of the top six bolts in order to obtain experimentally the actual tension force induced within each bolt. Then the connection behavior is characterized by the tension force in the bolt, extended end-plate behavior, moment-rotation relation, and beam and column strains. Some or all of these characteristics are used by many Standards; therefore, it is essential to predict the global behavior of column-beam connections by their geometrical and mechanical properties. The experimental test results are compared with two theoretical (equal distribution and linear distribution) approaches in order to assess the capabilities and accuracy of the theoretical models. A simple model of the joint is established and the essential parameters to predict its strength and deformational behavior are determined. The equal distribution method reasonably determined the tension forces in the upper two bolts while the linear distribution method underestimated them. The deformation behavior of the tested connections was characterized by separation of the column-flange from the extended end-plate almost down to the level of the upper two bolts of the lower group and below this level the two parts remained in full contact. The neutral axis of the deformed joint is reasonably assumed to pass very close to the line joining the upper two bolts of the lower group. Smooth monotonic moment-rotation relations for the all tested frames were observed.

An Evaluation of Lap Splice Length of Epoxy Coated Reinforcements Using Beam-End Test (보-단부 시험을 이용한 에폭시 도막 철근의 겹침 이음길이 평가)

  • Kim, Jee-Sang;Kang, Won Hyeak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.2
    • /
    • pp.175-182
    • /
    • 2020
  • The application of epoxy coated reinforcements is increased as a means to prevent a corrosion of reinforcements embedded in reinforced concrete structures, However, epoxy coating may reduce the bond capacity between concrete and reinforcement, which results a longer development length and lap splice length. This paper aims to the possibility of modification in lap splice length from reduction of basic development length which was confirmed using a direct pull out test. Total 36 beam specimens were tested to compare the lap splice properties of normal and epoxy coated reinforcements with beam-end test for various lap lengths and diameters of reinforcements. According to the results on failure modes, deformations, and crack widths of this experiments, the modification factor of 1.2 should be used, though the direct bond capacity is assured through direct pull out test.

Bearing Capacity of Cast-in-situ Concrete Piles Socketed in Completely Weathered Gneiss (풍화암에 근입된 현장타설말뚝의 지지거동 분석)

  • 전경수;김정환;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.6
    • /
    • pp.155-165
    • /
    • 1999
  • In completely weathered granite gneiss,8 of 40cm cast-in-situ concrete piles are constructed, and static pile load tests are executed on the piles to study the bearing behavior of rock-socketed piles. Subsurface explorations are carried out on the test site in three phases, in which 14 borehole investigations as well as the seismic investigation are performed. Rock socketd depths of the piles in the weathered rocks are varied as 3m, 6m and 9m to separate the shaft resistance from the end bearing resistance, and for a couple of piles, styrofoam of 10cm thickness is installed under the pile point to eliminate the effect of the end resistance. Strain gages are instrumented on re-bars to pick-up the transferred loads along the pile length. From the results of the pile load tests, the allowable shaft resistance and the allowable end bearing values of weathered rocks are proposed as $8.6t/m^2\;and\; 84t/m^2$, respectively. The empirical equation relating the elastic modulus of rock mass with the uniaxial compressive strength of the rock specimen is also proposed for the weathered rocks.

  • PDF

Estimation of I/Q Imbalance Parameters for Repeater using Direct Conversion RF with Low Pass Filter Mismatch (저역 통과 필터 불일치를 포함한 직접 변환 RF 중계기의 I/Q 불균형 파라미터 추정)

  • Yun, Seonhui;Lee, Kyuyong;Ahn, Jaemin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.18-26
    • /
    • 2015
  • In this paper, we studied the method for analyzing and estimating the parameters that induce I/Q imbalance in the repeater using direct conversion RF. In repeater, amplitude, phase, and filter mismatch are generated in the receiving-end which converts RF signal to baseband signal. And amplitude and phase mismatch are generated in the transmitting-end which converts baseband signal to RF signal. Accordingly, we modeled the parameters that cause I/Q imbalance in the structure of the repeater in order, and proposed a feedback test structure from the transmitting-end to the receiving-end for estimating the corresponding parameters. By comparing the test transmitting signal and received signal, it is possible to estimate the I/Q imbalance parameters which occurred from mixed components of real and imaginary part. And it was confirmed that I/Q imbalance phenomenon has been properly compensated with estimated parameters at the direct conversion RF repeater.

Changes in Ultimate Bearing Capacity according to the Position of the End of the Drilled Shaft (현장타설말뚝 선단부의 위치에 따른 극한지지력 변화)

  • Choi, Dong-Lo;Park, Kyeong-Ho;Kim, Chae-Min;Kim, Tae-Hyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.21 no.3
    • /
    • pp.49-59
    • /
    • 2022
  • This study was conducted to find out the rational and appropriate design of drilled shaft. In other words, in order to find out the variation of ultimate bearing capacity according to the change in the support layer of drilled shaft, back analysis was performed using the bi-directional pile load test performed on drilled shaft. Based on the back-analyzed data, numerical analysis of the pile head load was performed, and the ultimate bearing capacity in the target ground was evaluated using the Davisson method. As a result of numerical analysis of one case where the end of the pile was seated on the top of the weathered rock layer, and three cases where the end of the pile was embedded at different locations in the weathered soil, it was found that sufficient ultimate bearing capacity was secured in all cases. In other words, the case where the end of the pile is seated on the top of the weathered rock layer, not embedded the weathered rock, and the drilled shaft embedded into the weathered soil also have sufficient bearing capacity, so it can be used as a support layer for drilled shaft.

Bond behavior investigation of ordinary concrete-rebar with hinged beam test and eccentric pull-out test

  • Arslan, Mehmet E.;Pul, Selim
    • Computers and Concrete
    • /
    • v.26 no.6
    • /
    • pp.587-593
    • /
    • 2020
  • In this study, bond behavior of ordinary concrete and rebars with different diameters and development length was investigated by using Hinged Beam Test (HBT) and Eccentric Pull-Out Test (EPT) comparatively. For this purpose, three different rebar size and development length depending on rebar diameter were chosen as variables. Three specimens were produced for each series of specimens and totally 54 specimens were tested. At the end of the tests it was observed that obtained results for both tests were quite similar. On the other hand, increased bar size, especially for the specimen with 14 mm bar size and 14 development length (lb), caused shear failure of test specimens. This situation infers that when bigger bar size and lb are used in such test, dimensions of test specimens should be chosen bigger and stirrups should be used for producing of test specimens to obtain more adequate result by preventing shear failure. Also, a nonlinear regression analysis was employed between HBT and EPT results. There was a high correlation between the EPT values, lb, rebar diameters and estimated theoretical HBT. In addition, at the end of the study an equation was suggested to estimate bond strength for HBT by using EPT results.

Rotordynamic Characteristics of A Rigid Rotor Supported by A Sealed and Pressurized Squeeze Film Damper (가압 밀봉된 스퀴즈 필름 댐퍼로 지지된 로터의 동특성 연구)

  • 김창호;이용복;이남수;최상호;장효환
    • Tribology and Lubricants
    • /
    • v.15 no.4
    • /
    • pp.304-313
    • /
    • 1999
  • High-speed rotors set a lot of high vibration and stability problems especially when the speed of rotation is going through the first or the second critical speed. The aim of this paper is to investigate the possibility of an active control of a rigid rotor with squeeze film damper which has a good configuration of easily controlled end seal clearances and/or adjustment of a feed pressure. A theoretical method is presented and some numerical results are compared with test measurements. Both results show that the vibration or bit sizes are decreased when the end seal gap decreases with constant supply pressure, and when the supply oil pressure increases with constant seal gap. The experimental results show also a pleasing similarity on both orbit sizes and their decrement ratio compared with theoretical analysis. The possibility of an active control with the squeeze film damper was verified by adjusting the seal gap and the supply pressure.

Manufacturing and Performance Test of Obsolete Valve in NPP using DED Metal 3D Printing Technology (원전 단종 밸브의 DED 방식 금속 3D프린팅 제작 및 성능시험)

  • Kyungnam Jang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.75-82
    • /
    • 2021
  • The 3D printing technology is one of the fourth industrial revolution technology that drives innovation in the manufacturing process, and should be applied to nuclear industry for various purposes according to the manufacturing trend change. In nuclear industry, it can be applied to manufacture obsolete items and new designed parts in advanced reactors or small modular reactors (SMRs), replacing the traditional manufacturing technologies. A gate valve body was manufactured, which was obsolete in nuclear power plant, using DED(Directed Energy Deposition) metal 3D printing technology after restoring design characteristics including 3D design drawing by reverse engineering. The 3D printed valve body was assembled with commercial parts such as seat-ring, disk, stem, and actuator for performance test. For the valve assembly, including 3D printed valve body, several tests were performed, including pressure test, end-loading test, and seismic test according to KEPIC MGG and KEPIC MFC. In the pressure test, hydraulic pressure of 391kgf/cm2 was applied to 3D printed valve body, and no leak was detected. Also the 3D printed valve assembly was performed well in end-loading and seismic tests.