DOI QR코드

DOI QR Code

Changes in Ultimate Bearing Capacity according to the Position of the End of the Drilled Shaft

현장타설말뚝 선단부의 위치에 따른 극한지지력 변화

  • Received : 2022.07.19
  • Accepted : 2022.09.15
  • Published : 2022.09.30

Abstract

This study was conducted to find out the rational and appropriate design of drilled shaft. In other words, in order to find out the variation of ultimate bearing capacity according to the change in the support layer of drilled shaft, back analysis was performed using the bi-directional pile load test performed on drilled shaft. Based on the back-analyzed data, numerical analysis of the pile head load was performed, and the ultimate bearing capacity in the target ground was evaluated using the Davisson method. As a result of numerical analysis of one case where the end of the pile was seated on the top of the weathered rock layer, and three cases where the end of the pile was embedded at different locations in the weathered soil, it was found that sufficient ultimate bearing capacity was secured in all cases. In other words, the case where the end of the pile is seated on the top of the weathered rock layer, not embedded the weathered rock, and the drilled shaft embedded into the weathered soil also have sufficient bearing capacity, so it can be used as a support layer for drilled shaft.

본 연구는 현장타설말뚝의 합리적인 적정설계를 알아보기 위하여 수행하였다. 즉, 현장타설말뚝의 지지층 변경에 따른 극한지지력변화를 알아보기 위하여 현장타설말뚝에 대해 실시된 양방향 말뚝재하시험을 이용하여 역해석을 수행하였다. 역해석된 자료를 바탕으로 두부재하하중에 대한 수치해석을 진행하여 대상 지반에서의 극한지지력을 Davisson 판정법으로 평가하였다. 말뚝 단부가 풍화암층 상단에 안착된 1개의 경우와 풍화토 내 서로 다른 위치에 근입된 3개의 경우에 대한 수치해석 결과, 모든 경우에서 충분한 극한지지력을 확보하는 것으로 나타났다. 즉 말뚝의 단부가 풍화암 근입이 아닌 풍화암층 상단에 안착된 경우와 풍화토 내에 근입된 현장타설말뚝도 충분한 지지력을 가지고 있어 현장타설말뚝의 지지층으로 활용할 수 있음을 알 수 있다.

Keywords

References

  1. Abaqus (2018), User's Manual.
  2. Ahmadi, M. M. and Jazebi, M. (2018), "Side Resistance of Drilled Shaftsin Sandy Soils" 11th international congress on civil engineering, Tehran, Iran. pp.1-7.
  3. Busan Port Authority (2018), Busan Port (North Port) Redevelopment Project Connection Bridge (Phase 1) Construction, Design report.
  4. Cater, J. R. and Kulhawy, F. H. (1988), Analyisis and Design of Drilled Shaft Foundations Socketed into Rock, Report No. EPRL. EL-5918, Geotechnical Engineering Group, Cornell Univ.
  5. Choi, Y. K. (1999), "Suggestions for Improvement of Domestic Pile Foundation Design Routine - At a Viewpoint of Pile Bearing Capacity", Journal of the Korean Society of Civil Engineers, Vol.19, No.III-3, pp.467-477.
  6. Chun, B. S., Kim, S. M., Park, J. S. and Kim, E. S. (2006), "A Case Study on Evaluation of Bearing Capacity for Axially Loaded Drilled Shafts in Weathered Rock", In proceedings of the Korean Society of Civil Engineers, pp.4422-4425.
  7. Davisson, M. T. (1973), High Capacity of Piles, Proceedings of Lecture Series on Innovation in Foundation Construction, Illinois section, Chicago, pp.81-112.
  8. FHWA (1999), Drilled Shafts: Construction Procedures and Design Methods, FHWA Publication No. FHWA-IF-99-025. Department of Transportation, McLean, VA, Federal Highway Administration, Office of Implementation.
  9. Hong, W. P., Yea, G. G. and Lee, J. H. (2005), "Evaluation of Skin Friction on Large Drilled Shaft" Journal of the Korean Geotechnical Society, Vol.21, No.1, pp.93-103.
  10. Jung, S. J. (2010), Calibration of Resistance Factors of Load and Resistance Factor Design for Drilled Shafts Embedded in Weathered Rock, Seoul National Univ. Doctor's Thesis.
  11. Kim, D. Y., Joun, D. H. and Lee, Y. D. (2003), "Evaluation of Side Friction for Drilled Shafts Embedded in Weathered Rocks" In proceedings of the Korean Society of Civil Engineers, pp.3338-3341.
  12. Korean Geotechnical Society (2018), Explanation of Foundation Design Standards for Structures, CIR.
  13. Korean Society of Civil Engineers & Korea Bridge Design Engineering Research Center (2008), Highway Bridge Design Criteria, Kimoondang, pp.41 (in Korean).
  14. Kulhawy, F. H. and Phoon, K. K. (1993), "Drilled Shaft Side Resistance on Clay Soil to Rock", In Proceedings of the Conference on Design and Performance of Deep Foundations: Piles and Piers on Soil and Soft Rock, ASCE, Geotechnical Special Publocation 38, pp.172-183.
  15. Kwon, O. S., Cho, S. M., Jung, S. J. and Kim, M. M. (2005), "Load Transfer Mechanism of Drilled Shafts in Weathered Rock", Journal of the Korean Geotechnical Society, Vol.21, No.5, pp.187-196.
  16. Ministry of Land, Infrastructure and Transport (2016), Korean Highway Bridge Design Code (Limit State Design).
  17. Seo, Y. S., Yun, H. S., Kim, D. G. and Kown, O. I. (2016), "Analysis on Physical and Mechanical Properties of Rock Mass in Korea", The Journal of Engineering Geology, Vol.26, No.4, pp.593-600. https://doi.org/10.9720/KSEG.2016.4.593
  18. Seol, H. I, Jeong, S. S. and Kim, Y. H. (2008), Load-Transfer Analysis by Considering Coupled Soil Resistance, KSCE Journal of Civil and Environmental Engineering Research, Vol.28, No.6C, pp.359-366. https://doi.org/10.12652/KSCE.2008.28.6C.359
  19. Seol, H. I. (2008), Load Transfer Analysis of Rock-socketed Drilled Shafts by Considering Coupled Soil Resistance, Yonsei Univ. Doctor's Thesis.
  20. Zhang, L. and Einstein, H. (1988), "Estimationg the Mean Trace Length of Rock Discountinuities", International Journal of Rock Mechanics and Rock Engineering, Vol.31, No.4, pp.217-235. https://doi.org/10.1007/s006030050022