• 제목/요약/키워드: End Plate

검색결과 639건 처리시간 0.031초

이동지면 효과를 고려한 위그선용 저 종횡비 날개의 양력특성에 대한 실험연구 (Experimental Study on Lift Characteristics Considering Moving Ground Effects of Low Aspect Ratio Wings for Wing-In Ground Effect Crafts)

  • 안병권;구성필;류재문;노인식
    • 대한조선학회논문집
    • /
    • 제48권5호
    • /
    • pp.381-389
    • /
    • 2011
  • In this study, we are focusing our attention on lift characteristics of the low aspect wings for Wing-In Ground effect crafts (WIG). Experimental measurements at an open-type wind tunnel are carried out and results are comparatively presented. In order to simulate the realistic ground condition in where the WIG craft is flying, moving ground is implemented by a conveyor belt rotating with the same velocity of the inflow. We consider two different wings (NACA0012 and DHMTU section) which have four different aspect ratios (0.5, 1.0, 1.5 and 2.0). Forces acting on the wings are measured and lift characteristics are elaborately investigated for various different conditions. In addition, end-plate effects are estimated. Results are validated by comparing with theoretic solutions of the symmetric airfoil. Present results show that ground effects are differently generated in moving or fixed ground conditions, and hence left characteristics are affected by the ground condition. Consequently, accurate aerodynamic forces acting on the WIG craft are guaranteed in a realistic moving ground condition.

Development of 3 D.O.F parallel robot's simulator for education

  • Yoo, Jae-Myung;Kim, John-Hyeong;Park, Dong-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2290-2295
    • /
    • 2005
  • In this paper, it is developed simulator system of 3 D.O.F parallel robot for educate of expertness. This simulator system is composed of three parts ? 3 D.O.F parallel robot, controller (hardware) and software. First, basic structure of the robot is 3 active rotary actuator that small geared step motor with fixed base. An input-link is connected to this actuator, and this input-link can connect two ball joints. Thus, two couplers can be connected to the input-link as a pair. An end-plate, which is jointed by a ball joint, can be connected to the opposite side of the coupler. A sub-link is produced and installed to the internal spring, and then this sub-link is connected to the upper and bottom side of the coupler in order to prevent a certain bending or deformation of the two couplers. The robot has the maximum diameter of 230 mm, 10 kg of weight (include the table), and maximum height of 300 mm. Hardware for control of the robot is composed of computer, micro controller, pulse generator, and motor driver. The PC used in the controller sends commands to the controller, and transform signals input by the user to the coordinate value of the robot by substituting it into equations of kinematics and inverse kinematics. A controller transfer the coordinate value calculated in the PC to a pulse generator by transforming it into signals. A pulse generator analyzes commands, which include the information received from the micro controller. A motor driver transfer the pulse received from the pulse generator to a step motor, and protects against the over-load of the motor Finally, software is a learning purposed control program, which presents the principle of a robot operation and actual implementation. The benefit of this program is that easy for a novice to use. Developed robot simulator system can be practically applied to understand the principle of parallel mechanism, motors, sensor, and various other parts.

  • PDF

밀착조임 볼트체결에 따른 판폭두께비가 큰 변단면 프레임의 구조성능에 관한 실험적 연구 (Experimental Study on Structural Behavior of Tapered non-compact Frame with Snug-tightened Conditions)

  • 정경수;전배호;박만우;도병호
    • 한국강구조학회 논문집
    • /
    • 제24권3호
    • /
    • pp.257-265
    • /
    • 2012
  • 저층 장스팬 철골프레임에는 강재절감을 위해 휨모멘트 저항을 극대화 한 판폭두께비가 큰 변단면 부재를 이용한 PEB시스템을 사용하고 있다. 또한, 밀착조임 볼트접합은 완전조임 볼트접합에 비하여 공사비 절감과 시공용이성의 장점을 지니고 있다. 이에 본 연구에서는 밀착조임 볼트접합으로 이루어진 엔드플레이트형 접합형식에 판폭두께비가 큰 변단면 철골프레임의 실대형 실험을 행하였다. 변수로는 볼트체결방법과 재하하중방법이다. 프레임위치별 구조적 거동에 대해서 실험결과를 분석하고, 하중-변위관계에 대해서 해석결과와 비교하였다. 또한, 현장에서 밀착조임 볼트체결에 대한 볼트축력 도입과 사용성을 평가하였다.

아크릴릭 레진상을 이용한 클로르헥시딘의 방출에 관한 연구 (USE OF ACRYLIC RESIN IN RELEASING CHLORHEXIDINE)

  • 이은영;최영철
    • 대한소아치과학회지
    • /
    • 제25권4호
    • /
    • pp.797-810
    • /
    • 1998
  • The purpose of this study was to develop a new way of delivery system of chlorhexidine using self-curing acrylic resin. Different preparations of chlorhexidine, such as chlorhexidine varnish($Chlorzoin^{(R)}$) and chlorhexidine diacetate crystalline, were mixed into self-curing acrylic resin with different methods. Every resin plate was made and was immersed in 100ml of distilled water individually, and kept in an incubator at $37^{\circ}C$. Solution(0.8ml) was collected from the each container at every 24 hours, and the amount of released chlorhexidine in the solution was measured in an ultraviolet spectrophotometer at 255nm. Flexural strength of all of the resin plates in the Experiment 2-A and 2-B were measured using Instron at the end of the experimental periods. The results were as follows: 1. It was found that chlorhexidine was released from the experimental groups in the Experiment 1, 2-A, and 2-B. And the release of chlorhexidine from all of the experimental groups showed a pattern of sustained-release preparation. 2. It seemed likely that a condition of "dryness" reduced a release of chlorhexidine from the chlorhexidine varnish. 3. It may be stated that a method of "chlorhexidine diacetate mix" with the polymer be more efficient than a method of "Chlorzoin mix" with the monomer. 4. Although it was evident that a flexural strength of the acrylic resin plates be reduced by a mix of either Chlorzoin or chlorhexidine diacetate crystalline, it seemed likely that the resin plates except Group 4 and 5 in the Experiment 2-B may be usable in the clinical situation.

  • PDF

세탁 및 옷감 신장에 따른 천마스크 제품의 여과효율 변화 (Changes of Particle Filtration Efficiency of Cloth Masks by Machine Washing and Cloth Expansion)

  • 김승원
    • 한국산업보건학회지
    • /
    • 제27권2호
    • /
    • pp.115-122
    • /
    • 2017
  • Objectives: This study was designed to evaluate the changes in the particle filtration efficiencies of five cloth masks (4 plate types, 1 cup type) with an increasing number of machine washings and the degree of cloth expansion. Methods: NaCl aerosols were generated using an atomizer and passed through cloth masks in a dynamic aerosol chamber. Particle concentrations were measured both before and after for the cloth masks using an optical particle counter (OPC) in the size range of $0.3{\sim}10{\mu}m$. Results: In the original condition, the filtration efficiencies of the five cloth masks were A: 20.1%, B:30.9%, C: 25.0%, D: 26.5%, and E: 40.9%. As the number of washings increased in the order of one, two, and four times, the filtration efficiencies of cloth mask C increased. The filtration efficiency of A, D, and E increased after the first washing. With the exception of B, the filtration efficiency of cloth masks increased after the second washing and those of all cloth masks increased after the fourth washing. This might be caused by the fibers untangling from the yarn and being freed at one end. In this status, the packing density of the textile will not change, but the distances between fibers will increase, which might bring about an increase in filtration efficiency. When the cloth masks were extended by 10% and 20% in one direction, the filtration efficiencies of cloth masks B, D, and E decreased at 10% extension, and those of all cloth masks decreased at 20% extension. When the cloth masks were expanded by 10% and 20% in two directions, the filtration efficiencies of all cloth masks decreased by at least 34.7% at 10% extension, and by at least 60.9% at 20% extension Conclusions: The filtration efficiency of cloth masks could decrease after one to two machine washings, but will increase after four washings in comparison with their original performances. The filtration efficiency of cloth masks will decrease when they are expanded, such as when stretching over the nose during wearing status.

Orthodontic and orthopedic treatment for a growing patient with Tessier number 0 cleft

  • Baek, Seung-Hak;Park, Yoon-Hee;Chung, Jee Hyeok;Kim, Sukwha;Choi, Jin-Young
    • 대한치과교정학회지
    • /
    • 제48권2호
    • /
    • pp.113-124
    • /
    • 2018
  • The purpose of this case report was to introduce the concept of orthodontic and orthopedic treatment for a growing patient with Tessier number 0 cleft. A 5-year-old boy patient with Tessier number 0 cleft presented congenitally missing maxillary central incisors (MXCI), a bony defect at the premaxilla, a constricted maxillary arch, an anterior openbite, and maxillary hypoplasia. His treatment was divided into three stages: management of the bony defect at the premaxilla and the congenitally missing MXCIs using a fan-type expansion plate, iliac bone grafting, and eruption guidance of the maxillary lateral incisors into the graft area for substitution of MXCIs; management of the maxillary hypoplasia using sequential facemask therapy with conventional and skeletal anchorage; and management of the remaining occlusal problems using fixed orthodontic treatment. The total treatment duration was 15 years and 10 months. Class I canine and Class II molar relationships and normal overbite and overjet were achieved at the end of treatment. Although the long-term use of facemask therapy resulted in significant protraction of the retrusive maxilla, the patient exhibited Class III profile because of continued mandibular growth. However, the treatment result was well maintained after 2 years of retention. The findings from this case suggest that interdisciplinary and customized approaches are mandatory for successful management of maxillary hypoplasia, bony defect, and dental problems in Tessier number 0 cleft. Moreover, considering the potential of orthognathic surgery or distraction osteogenesis, meticulous monitoring of mandibular growth until growth completion is important.

지리산 읽기: 유토피아적 도피처에서 근대적 국립공원으로의 변형 - '산사람'의 도피주의적 삶을 중심으로 - (The Transforming Sacredness of Mt. Chirisan from an Utopian Shelter into a Modern National Park: Focused on the Escapist Lives of 'Mountain Men')

  • 진종헌
    • 대한지리학회지
    • /
    • 제40권2호
    • /
    • pp.172-186
    • /
    • 2005
  • 본 논문은 당대 지리산에 각인된 민족적 신성함이 어떻게 개인적, 사회적 실천과 그것의 역사적 반복을 통해 형성되어 왔는가를 검토한다. 본 연구는 '도피주의' 에 논의의 초점을 두고, 이를 위한 사례 연구로서 산사람의 삶과 부가적으로 청학동의 재발견 과정을 분석한다. 두 '산사람', 허만수와 함태식은 전근대에서 근대사회로 이행하는 과정에서 자연을 심미적 관점과 보호의 시각으로 바라보는 근대적 자연관을 암묵적으로 제시하였다. 그들은 도교적 유토피아를 찾으려는 내면적인 꿈과 근대적이고 민주적인 방식의 자연감상이라는 사회적 실천을 조화시키려고 시도하였다. 궁극적으로, 산사람의 출현과 그들의 실천은 지리산에 대한 전근대적인 지리적 상상-사회(세상)의 바깥에 존재하는 특별한 장소로서의 지리산-의 종말을 의미한다. 그리하여, 근대적 관광지이자 시민적 민족경관으로서의 지리산국립공원은, 사람들의 유토피아에 대한 꿈과, 산의 신성함과 그것이 민중의 삶을 보호할 것이라는 종교적인 믿음이 사라지는 지점에서 구체화되었다.

고장력 인장봉으로 보강된 RC 보의 휨 거동에 관한 실험적 연구(3) (An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(3))

  • 신경재;김윤정;문정호
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.351-358
    • /
    • 2007
  • 현재 상용되고 있는 강판 보강법이나 탄소섬유 시트 부착 보강법과는 달리, 고장력 인장봉을 이용한 외부 비부착 방식의 보강법은 설치가 간단하고 시공 시간이 짧은 등의 장점이 있다. 또한 외부 비부착 보강법은 콘크리트 표면처리가 필요 없고 에폭시 등의 접착제를 사용하지 않아 환경에 미치는 영향도 적다. 지난 연구에 이어 본 연구에서는 보강된 RC보에 관한 총 9개의 실대형 시험체를 변수별로 제작하여 여러 변수가 실제 구조물에 미치는 영향을 검토하였다. 시험체의 주요 변수는 보강재의 크기와 전단 보강근의 간격, 지지 조건이다. 본 논문에서는 보강된 RC 보의 구조적 거동을 무보강 시험체와 비교하여 기술하였다. 실험 결과 고장력 인장봉으로 보강된 RC보는 무보강 시험체와 비교하여 강도와 휨 성능에서 탁월한 효과를 나타내었으며 전단 보강근이 과소 배근된 시험체에서도 고장력 인장봉에 의한 전단 내력 효과를 보였다.

미세 연소기 개발 (II) - 미세동력 장치용 미세 전극의 제작과 성능평가 - (Design and Development of Micro Combustor (II) - Design and Test of Micro Electric Spark discharge Device for Power MEMS -)

  • 권세진;이대훈;박대은;윤준보;한철희
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.524-530
    • /
    • 2002
  • Micro electric spark discharge device was fabricated on a FOTURAN glass wafer using MEMS processing technique and its performance of electron discharge and subsequent formation of ignition kernel were tested. Micro electric spark device is an essential subsystem of a power MEMS that has been under development in this laboratories. In a combustion chamber of sub millimeter scale depth, spark electrodes are formed by electroplating Ni on a base plate of FOTURAN glass wafer. Optimization of spark voltage and spark gap is crucial for stable ignition and endurance of the electrodes. Namely, wider spark gaps insures stable ignition but requires higher ignition voltage to overcome the spark barrier. Also, electron discharge across larger voltage tends to erode the electrodes limiting the endurance of the overall system. In the present study, the discharge characteristics of the proptotype ignition device was measured in terms of electric quantities such as voltage and currant with spark gap and end shape as parameters. Discharge voltage shows a little decrease in width of less than 50㎛ and increases with electrode gap size. Reliability test shows no severe damage over 10$\^$6/ times of discharge test resulting in satisfactory performance for application to proposed power MEMS devices.

구순구개열과 관련된 상악골 변형의 치료를 위한 골신장술의 다양한 적용예 (Various Application of Distraction Osteogenesis in Cleft Lip and Palate related Deformities)

  • 이호;백승학;이종호;최진영
    • 대한구순구개열학회지
    • /
    • 제8권1호
    • /
    • pp.11-22
    • /
    • 2005
  • 상악골의 열성장과 횡적 부조화, 그리고 광범위한 치조열 및 구강상악동 누공의 치료에 있어서 기존의 방법에 비해 골신장술을 사용하였을 경우, 본 증례들과 관련 문헌 고찰을 통하여, 견인량의 충분한 확보 및 회귀율의 최소화를 얻을 수 있으며, 또한 입원가료기간의 감소와 연조직 부조화의 해결을 볼 수 있어 구순구개열에 관련된 상악골 변형의 치료에 골신장술이 유용한 치료법이라 생각되어 보고한다.

  • PDF