• 제목/요약/키워드: End Plate

검색결과 646건 처리시간 0.027초

스캐너와 산업용 로봇을 이용한 고속 레이저 용접에 관한 연구 (A Study on High Speed Laser Welding by using Scanner and Industrial Robot)

  • 강희신;서정;김종수;김정오;조택동
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.29-29
    • /
    • 2009
  • On this research, laser welding technology for manufacturing automobile body is studied. Laser welding technology is one of the important technologies used in the manufacturing of lighter, safer automotive bodies at a high level of productivity; the leading automotive manufacturers have replaced spot welding with laser welding in the process of car body assembly. Korean auto manufacturers are developing and applying the laser welding technology using a high output power Nd:YAG laser and a 6-axes industrial robot. On the other hand, the robot-based remote laser welding system was equipped with a long focal laser scanner system in robotic end effect. Laser system, robot system, and scanner system are used for realizing the high speed laser welding system. The remote laser welding system and industrial robotic system are used to consist of robot-based remote laser welding system. The robot-based remote laser welding system is flexible and able to improve laser welding speed compared with traditional welding as spot welding and laser welding. The robot-based remote laser systems used in this study were Trumpf's 4kW Nd:YAG laser (HL4006D) and IPG's 1.6kW Fiber laser (YLR-1600), while the robot systems were of ABB's IRB6400R (payload:120kg) and Hyundai Heavy Industry's HX130-02 (payload:130kg). In addition, a study of quality evaluation and monitoring technology for the remote laser welding was conducted. The welding joints of steel plate and steel plate coated with zinc were butt and lapped joints. The quality testing of the laser welding was conducted by observing the shape of the beads on the plate and the cross-section of the welded parts, analyzing the results of mechanical tension test, and monitoring the plasma intensity and temperature by using UV and IR detectors. Over the past years, Trumf's 4kW Nd:YAG laser and ABB's IRB6400R robot system was used. Nowadays, the new laser source, robot and laser scanner system are used to increase the processing speed and to improve the efficiency of processes. This paper proposes the robot-based remote laser welding system as a means of resolving the limited welding speed and accuracy of conventional laser welding systems.

  • PDF

헬리컬 파일의 지지력 산정을 위한 양방향 재하시험의 적용성 평가 (Applicability of Bi-directional Load Test for Evaluating Bearing Capacity of Helical Piles)

  • 이동섭;나경욱;이원제;김형남;최항석
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.77-85
    • /
    • 2014
  • 헬리컬 파일(helical pile)은 회전 관입기로 시공이 가능하므로 비교적 소형의 장비로 말뚝 시공이 가능한 장점이 있어, 최근 다양한 현장에서 그 사용이 증가하고 있다. 그러나 헬리컬 파일의 지지력을 평가하기 위한 현장 정재하시험은 시험하중만큼의 사하중, 반력 말뚝, 반력 앵커 등이 필요하다는 단점이 있다. 본 연구에서는 헬리컬 파일에 상대적으로 재하장치가 간단하고 시험이 간편한 양방향 재하시험을 적용하였으며, 양방향 재하시험 결과와 정재하시험 결과를 비교하였다. 양방향 재하시험은 헬리컬 파일의 중공형 중심축(shaft)에 중심축의 직경과 일치하고 중심축 내부 공간으로 유압재하용 호스가 나올 수 있도록 특수하게 제작된 유압식 셀(cell)을 나선형 원판(helix plate)사이에 삽입한 후, 유압 셀(cell)에 가압하여 지지력을 측정하는 방식으로 수행되었다. 양방향 재하시험은 유압식 셀을 최하단 나선형 원판 상부에 삽입한 경우와 최상단 나선형 원판 상부에 삽입한 두 가지 케이스로 시험을 진행하였으며, 각각의 방법이 선단지지력과 주면마찰력을 측정할 수 있도록 말뚝 두부의 변형을 제한하였다. 시험은 89mm, 114mm의 중심축에 450mm, 350mm, 200mm의 나선형 원판을 부착하여 제작한 헬리컬 파일로 수행되었으며, 시험 결과 정재하시험으로 산정한 지지력과 양방향 재하시험으로 산정한 지지력이 유사함을 확인하였다.

경추간판 탈출 환자의 전방 고정술에 따른 경제적 분석 - 골 이식법과 금속판 고정 병행술의 비교 - (Economical Analysis of Cervical Disc Disease by Anterior Inter-body Fusion Methods - Comparing of Bone Graft vs Plating -)

  • 길승배;이상열;허승호;장연규
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권2호
    • /
    • pp.201-206
    • /
    • 2001
  • Objective : The purpose of this study was to assess the complications, duration of admission, cost effectiveness, radiologic stabilization of the anterior cervical bone fusion in the treatment of cervical disc disease with and without plating. Materials and Methods : Fifty-two surgically treated patients for cervical disc disease were reviewed. Group I consisted of consecutive treated patients with iliac auto-bone graft without instrumentation after anterior cervical discectomy. Group II consisted of consecutive treated patients with iliac autologous-bone graft with CASPER cervical plate fixations. Radiologic fusion was decided when loss of end plate boundary between graft bone and vertebral body and immobile, maintenance of the disc space were evident on simple dynamic plain films. The patients were discharged after the stabilization of cervical motion by films was of tained. These groups were analysed multiple variably with Mann-Whitney U-test. Results : Group I consisted of 18 patients, group II consisted of 34 patients. Mean age was $49.0{\pm}8.1years$, mean duration of admission was $17.27{\pm}10.51days$, mean costs for treatment was $1,970,000{\pm}475,000won$. In group I, mean age was 47.7(34-60) years, 16 patients had undergo on one-level operation, 2-patients had undergo on two-level operation, mean duration of admission was $28.7{\pm}10.4days$, mean costs for treatment was $2,194,473{\pm}561,639won$. The periods of stabilization was $6.6{\pm}3.36weeks$ on radiologic study. Mean periods of out patient follow up was 16.8(6-64) weeks after discharge. Mean period of radiologic follow up was 17.3(4-6) weeks after surgical operation. In group II, mean age was 49.7(37-62) years and 18 patients one-level operation, 14- patients had undergo on two-level operation and 2-patients three-level operation. Mean duration of admission was $11.24{\pm}3.29days$, mean costs for treatment was $1,850,823{\pm}389,372won$. The periods of stabilization was $5.88{\pm}7.07weeks$ on radiologic study. Mean period of out patients follow up was 16.7(4-60) weeks after discharge. Mean period of radiologic follow up was 12.4(3-52) weeks after surgical operation. The duration of admission showed statistical significance in Group II but other items showed no significant difference between two groups. Conclusions : The more economic, early life return and effective method of cervical disc disease in our series were evident in patients who had undergone, iliac bone graft and plate fixations after anterior discectomy.

  • PDF

A numerical tool for thermo-mechanical analysis of multilayer stepped structures

  • Bagnoli, Paolo Emilio;Girardi, Maria;Padovani, Cristina;Pasquinelli, Giuseppe
    • Structural Engineering and Mechanics
    • /
    • 제48권6호
    • /
    • pp.757-774
    • /
    • 2013
  • An integrated simulation tool for multilayer stepped pyramidal structures is presented. The tool, based on a semi-analytical mathematical strategy, is able to calculate the temperature distributions and thermal stresses at the interfaces between the layers of such structures. The core of the thermal solver is the analytical simulator for power electronic devices, DJOSER, which has been supplemented with a mechanical solver based on the finite-element method. To this end, a new ele-ment is proposed whose geometry is defined by its mean surface and thickness, just as in a plate. The resulting mechanical model is fully three-dimensional, in the sense that the deformability in the direction orthogonal to the mean surface is taken into account. The dedicated finite element code developed for solving the equilibrium problem of structures made up of two or more superimposed plates subjected to thermal loads is applied to some two-layer samples made of silicon and copper. Comparisons performed with the results of standard finite element analyses using a large number of brick elements reveal the soundness of the strategy employed and the accuracy of the tool developed.

고효율 가압형 고분자전해질 연료전지 셀스택 개발 (Development of a High Efficiency Polymer Electrolyte Membrane Fuel Cell Stack under Pressurized Operating Conditions)

  • 한인수;서하규;정지훈;김민성;신현길;허택욱;조성백
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.125.1-125.1
    • /
    • 2010
  • A high efficiency polymer electrolyte membrane (PEM) fuel cell stack was developed for pressurized pure hydrogen and oxygen supplying conditions. The design objective for the cell stack was to maximize the electric efficiency and to minimize exhaust-gas emissions from it simultaneously. To achieve this objective, the cell stack was designed to use pure hydrogen and oxygen as fuel and oxidant, respectively, and to be operated under high gas inlet pressures and in a stage-wise dead-end operation mode. Major components constituting the cell stack, such as membrane electrode assembly, bipolar-plate, and gasket, have been developed to meet a target durability even in severe operating conditions: high gas inlet pressures and usage of pure oxygen. A high-power fuel cell stack was assembled using these components to verify the performance. The cell stack showed a good performance in terms of the efficiency and maximum power output.

  • PDF

Out-of-plane buckling and bracing requirement in double-angle trusses

  • Chen, Shaofan;Su, Mingzhou
    • Steel and Composite Structures
    • /
    • 제3권4호
    • /
    • pp.261-275
    • /
    • 2003
  • Truss members built-up with double angles back-to-back have monosymmetric cross-section and twisting always accompanies flexion upon the onset of buckling about the axis of symmetry. Approximate formulae for calculating the buckling capacity are presented in this paper for routine design purpose. For a member susceptible only to flexural buckling, its optimal cross-section should consist of slender plate elements so as to get larger radius of gyration. But, occurrence of twisting changes the situation owing to the weakness of thin plates in resisting torsion. Criteria for limiting the leg slenderness are discussed herein. Truss web members in compression are usually considered as hinged at both ends for out-of-plane buckling. In case one (or both) end of member is not supported laterally by bracing member, its adjoining members have to provide an elastic support of adequate stiffness in order not to underdesign the member. The stiffness provided by either compression or tension chords in different cases is analyzed, and the effect of initial crookedness of compression chord is taken into account. Formulae are presented to compute the required stiffness of chord member and to determine the effective length factor for inadequately constrained compressive diagonals.

헤더-채널 분기관의 각도변화가 2상 유동 분배에 미치는 영향에 대한 연구 (The Effect of Header and Channel Angle Variation on Two-Phase Flow Distribution at Multiple Junctions)

  • 이준경
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.559-566
    • /
    • 2015
  • The main objective of this work is to experimentally investigate the effect of angle variation on the distribution of two-phase flow at header-channel junctions. The cross-sections of the header and the channels were fixed at $16mm{\times}16mm$ and $12mm{\times}1.8mm$, respectively. Air and water were used as the test fluids. Four different header-channel positions were tested : Vertical header with Horizontal channels (case VM-HC), Horizontal header with Horizontal channels (case HM-HC), Horizontal header with Vertical Downward channels (case HM-VDC), and Horizontal header with Vertical Upward channels (case HM-VUC). In all cases, liquid flow distribution tended to decrease gradually in the upstream header region. However, in the downstream region, different trends could be seen. The reason for these different tendencies were identified by flow visualization in each case. The standard deviations for the liquid and gas flow distribution in each case were calculated, and the case of VM-HC had the lowest values compared to other cases because of the symmetrically distributed liquid film and strong flow recirculation near the end plate.

노인 여성 관절염 환자의 보행시간에 따른 지면반력의 특징 (In According to Walking Time The Character of the Ground Reaction Force in Elderly OA(Osteo-Arthritis) Female Patient)

  • 이정호;서정석;은선덕
    • 한국운동역학회지
    • /
    • 제17권2호
    • /
    • pp.75-82
    • /
    • 2007
  • The purpose of this study was to analyze and compare the effect of gait time on the gait patterns in elderly female OA and non-OA patients. The intensity of the subjects joint pain was surveyed by using WOMAC. Twelve subjects participated in this study. Measurements were taken for every the 10 minutes for 30 minutes after walking by a force plate. The following variables were recorded; double stance support time, Fx, Fy, Fx_time, Fz and so on. From the investigation of these variables the following was observed and concluded. The Fz values for the OA group was 1.01BW at the start and after 30 minutes was 1.04BW on the other hand the non-OA group's Fz1 was 1.08BW and 1.10BW. There was no significant difference calculated between the two groups and at the start and end of the experiment about all the variables. Therefore, it is concluded that there was no negative effect caused by walking for the 30 minutes and that it was an effective way of strengthen both respiratory and muscle function.

파력발전용 링타입 임펄스터어빈의 성능 해석 (A Study on the Performance of the Ring-type Impulse Turbine for Wave Energy Conversion)

  • 현범수;문재승;홍석원;김기섭
    • 한국해양공학회지
    • /
    • 제20권1호
    • /
    • pp.20-25
    • /
    • 2006
  • This paper deals with the design and aerodynamic analysis of a so-called 'ring-type' impulse turbine for wave energy conversion. Numerical analysis was performed using the CFD cock, FLUENT. The main idea of the proposed turbine rotor was to minimize the adverse effect of tip clearance of the turbine blade; the design was borrowed from a ducted propeller with connected ring tip for special purpose marine vehicles. Results show that the efficiency increases up to $10\%$, depending on flaw coefficient, with the higher flaw coefficient yielding better efficiency. Decrease of input coefficient CA was the main reason for higher efficiency. Performance of ring-type rotor at various design parameters, as well as flaw conditions, was investigated, and the advantages and the disadvantages of the present impulse turbine were also discussed.

딤플이 존재하는 2차원 수로유동의 계산 (Calculation of a 2-D channel flow with a dimple)

  • 최서원;백영호;김두연;강호철
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.49-56
    • /
    • 1997
  • Heat-transfer enhancement is seeked through modifications of fin surface. Real life plate-fin heat exchangers have complex three-dimensional geometries. Fins can have arrays of dimples and are attached to rows of penetrating tubes. To isolate the effect of surface modification, we model the real flow by a two-dimensional channel flow with a dimple on one side. The flow is analysed by solving the incompressible Navier-Stokes equation by a finite volume method on a generalized boundary-fitted coordinate. Results show a trapped vortex inside the dimple for all cases computed. Local maximum of Nusselt number occurs near the downstream end of the dimple, due to such a vortex. Location of the vortex does not change with respect to the wall temperature change, but moved downstream when Reynolds number increases. This, together with the results that in all cases vortex core is somewhat downstream of the dimple center, suggests that the mean flow above continuously feeds the kinetic energy to the recirculating flow. Heat transfer enhancement and pressure losses are studied through analysing the relevant dimensionless parameters like, Nusselt number and friction factor. In all cases computed, dimpled channel flow experiences less pressure loss than two-dimensional Poiseuille flow.