• 제목/요약/키워드: End Coupling

검색결과 195건 처리시간 0.029초

무선 심박측정 시스템에 적용 가능한 저주파 잡음 특성 개선의 RF 전치부 설계 연구 (Design of Low Frequency Noise Figure Improvement of RF Front End for Wireless Heartbeat Measurement System)

  • 최진규;백현;권소현;최혁재;김종호;신준영;김형석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1565_1566
    • /
    • 2009
  • This paper presents the design and analysis of RF Front End for Wireless Heartbeat measurement System. In this work LNA, an inductor connected at the gate of the cascode transistor and capacitive cross-coupling are strategically combined to reduce the noise and the nonlinearity influences of the cascode transistors in a differential LNA. The Mixer is implemented by using the Gilbert-type configuration, cross pmos injection technique and the resonating technique for the tail capacitance. The resulting LNA achieves 1.26dB NF, better than 1.88dB NF Typical. Also Mixer resulting achieves 9.8dB at 100KHz.

  • PDF

Designs for 25-kA and 40-kA Vapor-Cooled Bi2223/Copper Leads with the Bi2223 Section Operating in the Current-Sharing Mode

  • Lee, Haigun;Kim, Ho-Min;Yukikazu Iwasa;Kim, Keeman
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.222-230
    • /
    • 2003
  • This paper presents reference designs for vapor-cooled HTS/Copper leads rated at 25 kA and 40 kA and that satisfy a protection criterion. Each HTS section is cooled by the effluent helium vapor boiling from a 4.2-K bath. Each HTS section is based on a design concept in which a short portion of its warm end (77.3 K) operates in the current-sharing mode; such operation results in a considerable saving for HTS materials required in the HTS section. Two designs of "fully superconducting" vapor-cooled HTS sections, one rated at 25 kA and the other at 40 kA are also presented as comparison bases for the new HTS sections. Each warm end of HTS sections is coupled to an optimal vapor-cooled copper lead rated at the same current as that for the HTS section. The extra coolant required at 77.3 K at the coupling station, an optimal length of the copper section will be shorter than that optimized for helium-vapor cooling between 4.2 K and room temperature.mperature.

Crosstalk를 방지한 100 MHz 고속 데이터 전송 Modular Jack의 설계 및 제작에 관한 연구 (A Study on a Reduced Crosstalk for the Design of 100 MHz High Speed Data Transmission Modular Jack)

  • 이중근;안현수
    • 한국전자파학회논문지
    • /
    • 제10권1호
    • /
    • pp.1-10
    • /
    • 1999
  • 본 논문에서는 100 Mb/s Unshielded Twisted Pairs (UTP) 케이블 Modular Jack의 평형 통신 시스템(Balanced Communication System)에서 시스템의 성능에 영향을 주지 않으변서, UTP 케이블의 꼬임이 풀림 으로 인해 서로 근접하게 배치된 평형통신 선로(Balanced Communication Lines)간에 존재하는 불균일한 결 합으로 인한 차등 누화 선호(Differen tial- Mode Crosstalk Signal)를 효과적으로 제거하거나 억제시킬 수 있는 접근 방법에 대하여 논하고 있으며, 실제 UTP 케이블의 Modular Jack에 이를 적용시켜 이에 대한 큰단누화 (Near-End Crosstalk (Next)를 측정함으로써 그 타당성을 입증하였다.

  • PDF

Investigating the effect of edge crack on the modal properties of composite wing using dynamic stiffness matrix

  • Torabi, Ali Reza;Shams, Shahrokh;Fatehi-Narab, Mahdi
    • Steel and Composite Structures
    • /
    • 제39권5호
    • /
    • pp.543-564
    • /
    • 2021
  • In this study free vibration analysis of a cracked Goland composite wing is investigated. The wing is modelled as a cantilevered beam based on Euler- Bernoulli equations. Also, composite material is modelled based on lamina fiber-reinforced. Edge crack is modelled by additional boundary conditions and local flexibility matrix in crack location, Castigliano's theorem and energy release rate formulation. Governing differential equations are extracted by Hamilton's principle. Using the separation of variables method, general solution in the normalized form for bending and torsion deflection is achieved then expressions for the cross-sectional rotation, the bending moment, the shear force and the torsional moment for the cantilevered beam are obtained. The cracked beam is modelled by separation of beam into two interconnected intact beams. Free vibration analysis of the beam is performed by applying boundary conditions at the fixed end, the free end, continuity conditions in the crack location of the beam and dynamic stiffness matrix determinant. Also, the effects of various parameters such as length and location of crack and fiber angle on natural frequencies and mode shapes are studied. Modal analysis results illustrate that natural frequencies and mode shapes are affected by depth and location of edge crack and coupling parameter.

종합편성채널의 부상과 오락적 정론장(政論場)의 형성 정치-미디어 체계 간 구조적 접속의 새로운 양상 (The Emergence of General Programming Channels and the Formation of Entertaining Media-Political Sphere A New Pattern of Structural Coupling between the Political and the Media Systems)

  • 정준희
    • 한국언론정보학보
    • /
    • 제77권
    • /
    • pp.73-107
    • /
    • 2016
  • 이 연구는 한국 사회의 종합편성채널이 단지 미디어 산업 내부에서의 경제적 효과에 국한되지 않는 광범위 사회적 영향력을 지닌 저널리즘 기구로 성장했다고 판단한다. 종합편성채널은 방송 저널리즘이라는 특수한 사회적 행위에 기초를 두어 다양한 특권을 확보하고 그를 통해 비즈니스적 운신의 폭을 넓히는 사회정치적 제도의 일종인 셈이다. 따라서 이 연구는 종합편성채널의 사회정치적 특성을 규명하기 위한 목적에서 이론적 자원을 검토하고 적절한 개념적 장치를 마련하는 데 초점을 맞춘다. 이를 위해 정치와 미디어 사이의 상호 관계성을 다루는 다양한 개념과 이론에 주목하는데, 정치에 의한 미디어의 도구화, 미디어 권력화, 정치 병행성, 정치-미디어 체계 간 구조적 접속 등이 그것이다. 이론적 검토와 개념화의 결과로, 이 연구는 종합편성채널이 정치 체계와 미디어 체계의 구조적 접속을 상시화하는 새로운 인터페이스로 부상했으며, 미약하게나마 존재하고 있던 미디어 공론장의 쇠락을 촉진하면서 그것을 대체하는 오락적 정론장을 형성시켰다고 제안한다. 오락적 정론장은 정치 체계의 정치 논리와 미디어 체계의 미디어 논리가 착종되는 독특한 공간으로서, 정치의 미디어화는 물론 미디어의 정치화를 동시에 가속화시키는 기능을 수행하고 있다고 판단한다. 이로 인해 정치-미디어 체계 사이의 기존 경계가 붕괴되는 상황이 촉발될지, 아니면 제3의 체계 형성이 유도될지 속단하기는 아직 이르다. 다만 새로운 인터페이스로 부상한 이 오락적 정론장이 정치 체계와 미디어 체계의 작동에 영향을 미침으로써 부분적 구조 변화로 이어질 가능성을 타진해 볼 필요는 있다.

  • PDF

두경부 유리피판 수술에 있어서의 비천공성 혈관 클립을 이용한 미세혈관 문합술 (Microvascular Anastomosis with Non-penetrating Vascular Clips in Head and Neck Free Flap Surgery)

  • 장학;민경원;김우람;신현우;고경석
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권1호
    • /
    • pp.57-62
    • /
    • 2005
  • Microvascular anastomosis with suture technique is a basic skill but there are several problems such as stenosis, thrombosis and long operating time. Recently plastic surgeons have developed non-suturing mechanical coupling devices for microvascular anastomosis. The authors applied non-penetrating vascular clips (VCS clips) in the field of free flap surgery of head and neck area. Between August of 2004 and January of 2005, we performed 9 free flaps (16 vessels) using small-sized VCS clips. Four stay sutures were applied first and then VCS clips were placed between sutures about 1 mm apart. Vascular pedicle of free flap included the descending branch of lateral circumflex femoral vessel, thoracodorsal vessel, deep inferior epigastric vessel and cephalic vein. The recipient vessels were the superior thyroid artery, superficial temporal artery, internal jugular vein, external jugular vein, and superficial temporal vein. We performed 13 end-to-end (4 arteries and 9 veins) and 3 venous end-to-side anastomoses. No flap related complication occurred but we applied additional clips or sutures in two cases due to blood leakage after completion of anastomosis. Primary patency rates seemed to be good and more rapid anastomosis could be done than conventional suture technique. Advantages of VCS technique are high patency rate, low thrombogenecity and rapidity. Although the high cost of VCS instrument may be a problem, this clip could be applied safely in microvascular free tissue transfer.

  • PDF

차동 커패시터 커플링을 이용한 연속근사 ADC (Differential Capacitor-Coupled Successive Approximation ADC)

  • 양수열;모현선;김대정
    • 전기전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.8-16
    • /
    • 2010
  • 본 논문에서는 CCD 이미지 처리를 위한 최대 15MS/s의 속도의 중저속 아날로그-프론트 엔드(analog-front end, AFE)에서 사용될 수 있는 연속근사 ADC(Successive Approximation ADC, SA-ADC)의 설계를 제안한다. 파이프라인 ADC와 달리 SA-ADC는 동작주파수의 변화에 따른 전력소모의 스케일링(scaling) 효과가 크므로 저속에서 중속에 이르는 넓은 범위의 가변 데이터 처리 속도의 응용에 매우 효과적이다. 제안하는 설계는 입력 신호의 샘플링 동작을 내부 DAC(sub-DAC)로부터 따로 분리한 후, 커패시터 커플링을 통해 차동 결합함으로써 신호경로에 이르는 부하를 크게 줄이는 "차동 커패시터 커플링 기법"의 도입, 연속근사의 기법적 측면에서 signed 구조를 활용하여 데이터 변환주기 이전에 홀드된 입력신호로부터 미리 MSB(sign bit)를 결정함으로써 1사이클의 변환주기를 절약하고 내부 DAC의 하드웨어를 1비트 줄이는 구조와 같은 특징을 갖고 있다. 본 설계는 3.3V $0.35{\mu}m$ CMOS 공정으로써 설계하고 Spectre 시뮬레이션을 이용하여 그 특성을 분석함으로써 CCD 아날로그 프론트-엔드에 적용될 수 있음을 입증하였다.

폴리에틸렌의 열분해 Kinetics (Thermo-Degradation Kinetics of Polyethylene)

  • 차왕석
    • 공업화학
    • /
    • 제10권3호
    • /
    • pp.432-437
    • /
    • 1999
  • 폴리에틸렌 열분해실험을 반응기 크기가 $10cm^3$인 스테인레스 스틸 반응기에서 수행하였으며 이때 반응온도는 $390{\sim}450^{\circ}C$이었다. 열분해생성물인 반응생성물과 기체생성물을 분리하여 채취하였고 각 생성물의 분자량분포는 HPLC-GPC와 GC분석을 통해 얻었다. 열분해반응의 개시-종료, 전파-비전파반응, 즉 수소탈취반응, 사슬절단, 고분자물질과 라디칼과의 결합반응 등을 설명할 수 있는 random, specific 생성물의 분자랑분포에 대한 distribution balance식을 제안하였다. 말단절단 과정에 의해 저분자량의 비응축성 기체생성물 (C1~C5)이 생성되었으며 이 기체생성물의 평균분자량은 38이었다. 무작위절단과 말단절단의 속도매개변수 중의 하나인 활성화에너지는 각각 35, 17 kcal/mole 이었다.

  • PDF

Study on Leading-phase Operation Capability of a 770 MW Jumbo Hydro-generator based on Stability Analysis and End-Region Heat Analysis

  • Fan, Zhen-nan;Zhou, Zhi-ting;Li, Jian-fu;Wen, Kun;Wang, Jun;Sun, Zhang;Wang, Tao;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1317-1325
    • /
    • 2018
  • A generator-grid coupling calculation model is established to study the leading-phase operational capability of a 770 MW jumbo hydro-generator in a Chinese ultra-mega hydropower station. The static and dynamic stability of the generator are analyzed and calculated to obtain stability limits under leading-phase operating conditions. Three-dimensional (3D) time-varying nonlinear moving electromagnetic and temperature field models of the generator end-region are also established and used to determine the magnetic field, loss, and temperature of the end-region under the leading-phase operating condition. The simulation results agree with data measured from the actual 770 MW hydro-generator. This paper provides reliable reference data for the leading-phase operation of a jumbo hydro-generator, which will help to improve in the design and manufacture of future hydro-generators.

Analytical approximate solution for Initial post-buckling behavior of pipes in oil and gas wells

  • Yu, Yongping;Sun, Youhong;Han, Yucen
    • Coupled systems mechanics
    • /
    • 제1권2호
    • /
    • pp.155-163
    • /
    • 2012
  • This paper presents analytical approximate solutions for the initial post-buckling deformation of the pipes in oil and gas wells. The governing differential equation with sinusoidal nonlinearity can be reduced to form a third-order-polynomial nonlinear equation, by coupling of the well-known Maclaurin series expansion and orthogonal Chebyshev polynomials. Analytical approximations to the resulting boundary condition problem are established by combining the Newton's method with the method of harmonic balance. The linearization is performed prior to proceeding with harmonic balancing thus resulting in a set of linear algebraic equations instead of one of non-linear algebraic equations, unlike the classical method of harmonic balance. We are hence able to establish analytical approximate solutions. The approximate formulae for load along axis, and periodic solution are established for derivative of the helix angle at the end of the pipe. Illustrative examples are selected and compared to "reference" solution obtained by the shooting method to substantiate the accuracy and correctness of the approximate analytical approach.