• 제목/요약/키워드: Enclosure System

검색결과 170건 처리시간 0.029초

초고층 건축물의 수직 구획화에 따른 급기가압제연시스템 성능평가에 관한 연구 (A Study on the Smoke Control Performance Evaluation of High-rise Buildings under Smokeproof Enclosure Design Scenarios)

  • 배상환;류형규;이병석
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.343-350
    • /
    • 2014
  • Regardless of the building design scenarios, evaluation of high-rise buildings required to have smoke-proof enclosures that are provided with a smoke management system. The goal of the smoke management system design is to make sure the pressure differentials at every story within the building fall within the allowable pressure range. If the minimum design pressure is not met, smoke may enter the stair. If the provided pressure is too great, it becomes difficult for occupants to open the doors, while attempting to egress. Ensuring that the pressure differential between the vestibule and the floor is within the prescribed range becomes challenging, due to natural effects on the building, such as the stack effect. In this research, smokeproof enclosure design scenarios were evaluated; and as a result, separation levels for compartmentation were deduced, in the balancing of pressurized-vestibule smoke control systems.

저 주파수 벽면 가진에 의한 밀폐공간 내부 온도장의 공진 특성 실험 (An Experimental Study on Resonance of Temperature Field by Low-Frequency Oscillating Wall in a Side Heated Enclosure)

  • 김서영;김성기;최영돈
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1272-1280
    • /
    • 2001
  • An experimental study has been conducted to elucidate the resonance of natural convection in a side-heated square enclosure having a mechanically oscillating bottom wall. Under consideration is the impact of the imposed oscillating frequency, amplitude and the system Rayleigh number on the fluctuation of air temperatures. The experimental results show that the magnitude of the fluctuation of air temperature is substantially augmented at a specific forcing frequency of the oscillating bottom wall. The resonant frequency is increased with the increase of the Rayleigh number and it is little affected by the amplitude of the oscillating wall. It is also found that the resonant frequency is relevant to the Brunt- V$\"{a}$iS$\"{a}$l$\"{a}$ frequency which represents the stratification degree of the system.

직육면체 공동 내부의 소음 저감을 위한 능동 구조-음향 연성제어

  • 이상원;황철호;이장무
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.218-223
    • /
    • 1997
  • The technique used is the active structural acoutrol (ASAC)approach which involves controlling the acoustic response of a panel-cavity covpled system by applying oscillating force inputs in the form of prezoelectric actuators directly to the flexible panel. The linear quadratic Gaussian control scheme is used for attenuating nosie inside the rectangular enclosure causing by flexible wall vibration. Results indicated the application of control inputs to the radiating wall resukted in considerable noise reductions inside the cavity. Auso,the possibility of application to the more complicated fluid-structure coupled system is verified.

열차제어컴퓨터 시리얼통신변환장치(HADAX)의 성능개선에 관한 연구 (Performance improvement of serial communication converter of train control computer)

  • 조봉관
    • 한국도시철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.427-436
    • /
    • 2018
  • HADAX는 열차제어컴퓨터의 시리얼 통신변환장치로서 선로변 신호설비와 역의 신호설비 및 열차제어컴퓨터 등 여러 신호설비와 연결되어 있으며 열차제어를 위한 제어정보 및 신호설비의 상태정보를 전송한다. 그리고 스플리터 인터페이스를 통해 여러 대의 전자연동장치와 정보를 전송하고 있다. HADAX는 여러 신호 장치들과 시리얼 통신으로 인터페이스하고 있어 통신 접속 장애가 빈번히 발생하여 이중계 구성, 외부 스플리터 통합, 통신카드의 다채널화 등 성능개선이 필요하다. 성능이 개선된 HADAX 장치는 기존 장치와 외함의 치수와 커넥터의 호환성을 가져야 하며 이중계 절체, 스플리터 통합에 대한 성능을 검증하여야 한다. 따라서 기존에 구축된 신호설비와 연결하여 스플리터 통합 구성으로 진로제어시험, 이중계 절체시험, 다채널 통신시험을 통해 HADAX의 성능을 검증하였다.

NUMERICAL ANALYSIS FOR PRANDTL NUMBER DEPENDENCY ON NATURAL CONVECTION IN AN ENCLOSURE HAVING A VERTICAL THERMAL GRADIENT WITH A SQUARE INSULATOR INSIDE

  • Lee, Jae-Ryong;Park, Il-Seouk
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.283-296
    • /
    • 2012
  • The natural convection in a horizontal enclosure heated from the bottom wall, cooled at the top wall, and having a square adiabatic body in the center is studied. Three different Prandtl numbers (0.01, 0.7 and 7) are considered for the investigation of the effect of the Prandtl number on natural convection. Adiabatic boundary conditions are employed for the side walls. A two-dimensional solution for unsteady natural convection is obtained, using an accurate and efficient Chebyshev spectral methodology for different Rayleigh numbers varying over the range of $10_3$ to $10_6$. It had been experimentally reported that the heat transfer mode becomes oscillatory when Pr is out of a specific Pr band beyond the critical Ra. In this study, we reproduced this phenomenon numerically. It was found that when Ra=$10_6$, only the case for intermediate Pr (=0.7) reached a non-changing steady state and the low and high Pr number cases (Pr=0.01 and 7) showed a periodically oscillatory fashion hydrodynamically and thermally. The variation of time- and surface-averaged Nusselt numbers on the hot and cold walls for different Rayleigh numbers and Prandtl numbers are presented to show the overall heat transfer characteristics in the system. Further, the isotherms and streamline distributions are presented in detail to compare the physics related to their thermal behavior.

우리나라에서 사용하는 광물유의 유해특성과 관리대책에 관한 연구 - 공기중 MWF 미스트의 측정방법과 관리대책 - (Control and Investigation for Hazardous Characteristics of Metal Working Fluids Used in Korea - A Study on the Control and Sampling Method for Airborne MWF mist -)

  • 백남원;박동욱;윤충식;조숙자;김신범;임호섭
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.171-180
    • /
    • 1997
  • The objectives of this study were both 10 discuss the sampling method for airborne metalworking fluids(MWF)' mist and 10 suggest measures to minimize worker's exposure to carcinogen contained in metalworking fluids. In order to measure airborne MWF mist, it seems to be appropriate to use NIOSH Method #0500(filler weight) rather than NIOSH Method # 5026(analysis by FTIR). Because MWF mist on PVC filter evaporated and migrated during sampling, worker's exposure to MWF could be underestimated. So, when evaluating worker's exposure to MWF mist, other environmental conditions also must be considered. Enclosure and local exhaust ventilation system seems to he the most effective measure and must be constructed with process facility. In order to control worker exposure to carcinogens contained in MWF, distillation type and condition for crude oil, PAH concentration in MWF, and viscosity index of MWF must legally be described.

  • PDF

Effect of Metallic Particles on E-field Enhancement in Extra High Voltage Gas-insulated Transmission Lines

  • Rao, M. Mohana;Satyanarayana, S.;Kumar, S. Vinay;Jain, H.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.631-636
    • /
    • 2010
  • Gas-insulated transmission lines (GITL) are valued as technological solutions in hydro-power stations due to their enormous power handling capabilities. The performance of GITL is a function of the size of metallic particles inside the gas-insulated chamber. Electrostatic field (E-field) enhancement is a common phenomenon in gas-insulated lines due to these metallic particles. In this study, the E-field enhancement factor is calculated by considering metallic particles at various locations in the gas-insulated line/bus section, such as high-tension (HT) conductor, high-voltage shields, support insulator, and inner surface of grounded enclosure. For this purpose, a two-dimensional model based on finite element (FE) method is developed. The length of the metallic particle is in the range of 1 to 10 mm while the diameter is between 1 to 3 mm. E-field enhancement is also computed for various particle configurations of the gas-insulated system, with focus on dielectric coating made of epoxy on HT conductor and inner surface of grounded enclosure.

사각 단열체가 존재하는 밀폐계 내부에서 Pr수 변화에 따른 자연대류 현상에 대한 수치적 연구 (NUMERICAL STUDY FOR PRANDTL NUMBER DEPENDENCY ON NATURAL CONVECTION IN AN ENCLOSURE WITH SQUARE ADIABATIC BODY)

  • 이재룡
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.29-36
    • /
    • 2011
  • The natural convection in a horizontal enclosure heated from the bottom wall, cooled at the top wall, and having a square adiabatic body at its centered area was studied. Three different Prandtl numbers (0.01, 0.7 and 7) were considered for an effect of the Prandtl number on natural convection. A two-dimensional solution for unsteady natural convection was obtained, using Chebyshev spectral methodology for different Rayleigh numbers varying over the range of $10^4$ to $10^6$. It had been experimentally and numerically reported [1,2] that the heat transfer mode becomes oscillatory when Pr is out of a specific Pr band beyond the critical Ra. In this study, we reproduced this phenomenon numerically. The variation of time- and surface-averaged Nusselt numbers on the hot and cold walls for different Rayleigh numbers and Prandtl numbers was presented to show the overall heat transfer characteristics in the system. And also, the isotherms and streamline distributions were presented in detail to compare the physics related to their thermal behavior.

도시철도 구내정보통신 기반설비 표준화 및 기능 향상방안 (Metro Telecommunication Basis Facilities Standardization and Functional Improvement Research)

  • 김문태;윤인영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.964-968
    • /
    • 2005
  • The standardization of information communication is doing a Internal each other connection and each other characteristic stability operation security in objective. From the low-speed network of the subway operation beginning currently it changes with the superhigh speed digital information transmission communication service environment which is a quality service, the hazard which plans the quality improvement of the efficient communication service use which hits to here and passenger service the standardization of the technical standard which stands and the improvement which hits to an engineering standard and facility must come to accomplish. The facility which existing is been old or the enclosure communication equipments which are insufficient. it improves, establishment itexpands efficiently, like this facilities it is stabilized and it is economic and rationally use maintenance it manages with the plan for the inside and outside of the country information communication relation technical standard and engineering standard service feature improvement and future expandability and economical efficiency, the possibility of having a pliability in order to be, rational technical standard and standard it takes a triangular position, efficient characteristic security of information communication service there is a place objective which promises the rational development of course city railroad communication system with character. Function improvement of enclosure communication base equipment, against an improvement and standardization plan it described trom the prosecution which it sees.

  • PDF

산고래 온돌연도내의 유동분포에 관한 수치해석 (Numerical Analysis on the Flow Distribution in Ondol Flue Channel)

  • 민만기;이승우
    • 대한설비공학회지:설비저널
    • /
    • 제12권4호
    • /
    • pp.264-274
    • /
    • 1983
  • Two-dimensional jet flows into a couple of confined rectangular enclosures such as an Ondol flue channel and their flow distributions were analyzed by numerical graphics : rectangular space in one enclosure is vacated and the other has 8 rectangular small posts. Both enclosures have a protruded inlet nozzle and on outlet on its center line. Steady state incompressible laminar viscous flow was assumed. The primitive forms of Navier-Stokes equations and continuity equation in a cartesian coordinate system were solved numerically by the Marker and Cell method for Reynolds numbers of 5, 10, 20, 30 and 40. From the numerical graphics it was found that the flow regions in both enclosures were devided into tow parts ; one part was the jet flow localized in a narrow center region of the enclosure and the other part was the very slow recirculating flow occupying the rest of the flow region in the enclosures. However there were a little differences in the shapes of jet flow in both enclosures for Reynolds numbers of 5 and 10 and also in the shapes of recirculating flows in both enclosures for all Reynolds number. Also it was found that waving flow appeared right before the outlet at Reynolds number of 20 and more.

  • PDF