• 제목/요약/키워드: Enamel thickness

검색결과 85건 처리시간 0.021초

광중합복합레진의 두께에 따른 투명도 차이가 수복물의 색상에 미치는 영향 (TRANSLUCENCY OF LIGHT CURED COMPOSITE RESINS DEPENDS ON THICKNESS & ITS INFLUENCE ON COLOR OF RESTORATIONS)

  • 황인남;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.585-603
    • /
    • 1999
  • Esthetic availabilities used as an esthetic restorative maternals can be determined by the optical coincidence among materials, enamel and dentin. Enamel is highly translucent. That's why esthetic materials need to correspond the close translucency of enamel. But the translucent materials are affected by the background color. So it should be predicted that the color of estorative materials depend on the any thickness and the spectral reflectance of the background on which they are placed. The object of this investigation, under above hypothesis, was to determine and analyze how they affect the final color according to the thickness, translucency and background color (white, black and dentin) fill three commercial light cured composite resins(Charisma, Spectrum TPH and Z100). And correlation was analyzed to find out the possibility of the prediction when using the certain background color and thickness of materials. Followings are the result 1. The I shade of CHA showed the lowest contrast ratio($Co_7$) while the B3 shade of Z100 showed the highest contrast ratio(p<0.05). 2. The value of $L^*$ and $b^*$ on the white and dentin background is increased with decreasing thickness. And there are significant relationships between increasing thickness and each value(R>0.085). But there is a little change of $L^*$ and $b^*$ value on the black background regardless of the thickness(p>0.05). 3. For the $a^*$ value, there was little difference in values as a function of thickness and changed irregularly regardless of thickness in all background. 4. The pattern of increasing value of $L^*$ and $b^*$ with decreasing thickness was similar to the group of white and dentin background. In both dentin one showed lesser change of value. 5. The values of $L^*a^*b^*$ measured on the different background with same thickness showed the recognizable color difference(${\Delta}E^*$>2) when the thickness was below 2.6mm. 6. Contrast ratio was increased with increasing thickness with significant relationship (R>0.9). 7. Spectral reflectance of composite resins that calculated from Kubelka-Munk equation was showed little difference compared with observed value w1th decreasing thickness.

  • PDF

치관 전장용 레진의 내마모성에 대한 비교연구 (A COMPARATIVE STUDY ON THE WEAR RESISTANCE OF POLYMERIC VENEERING MATERIALS)

  • 윤수선;이선형;양재호;장완식
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.33-43
    • /
    • 1986
  • The purpose of this study was to compare the wear resistance of heat pressure-cured microcomposite(SR-Isosit-N), photo-cured microcomposite(Dentalcolor), unfilled heat-cured resin(Thermojel) and that of human enmel. Specimens were made with specially designed die and finally polished with #3,000 diamond paste. After 100,000 strokes of tooth brushing at electric tooth-brushing machine, mean thickness loss of each specimen was measured by using surface profile and integration. The results were as follows 1. Mean thickness loss were $84.3{\pm}27.3{\mu}m$ in unfiled heat-cured resin, $9.4{\pm}2.5{\mu}m$ in photocured microcomposite, $7.6{\pm}2.1{\mu}m$ in heat.pressure-cured microcomposite and $0.97{\pm}0.42{\mu}m$ in enamel. 2. Heat.pressure-cured microcomposite and photo-cured microcomposite had no difference in mean thickness loss(p>0.05). 3. Unfilled resin and microcomposite had much differences in mean thickness loss (p<0.005). 4. ha resins used in this experiment had too much mean thickness loss as compared with enamel (p<0.005).

  • PDF

정중 과잉치 법랑질의 SEM/EDS 분석 (SEM/EDS Analysis of the Enamel in Mesiodens)

  • 오나경;이제식;남순현;권태엽;김현정
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.101-110
    • /
    • 2019
  • 이 연구는 정중 과잉치 법랑질의 구조학적 및 형태학적 특징에 대하여 주사형 전자현미경(FE-SEM)과 에너지 분산형 분광분석법(EDS)을 이용하여 관찰하고 영구 중절치와 유중절치의 법랑질 구조 및 형태와 차이점에 대하여 평가하고자 하였다. 15개의 정중 과잉치, 영구 중절치와 유중절치를 이용하였으며, 법랑질의 두께와 법랑소주 직경에 대하여 FE-SEM을 이용하여 측정 및 관찰하고, 성분 분석을 위하여 EDS를 이용하였다. 그 결과 법랑소주 두께의 경우 영구 중절치, 정중 과잉치, 유중절치 순으로 나타났다. 법랑소주의 직경의 경우 영구중절치와 정중 과잉치에서는 유의할 만한 차이가 없었으며, 유중절치는 두 그룹에 비해서 작게 나타났다. 성분 분석 시 칼슘의 경우 영구 중절치와 정중 과잉치에 있어서 통계적 유의성이 없었으며, 유중절치는 작게 나타났다. Ca/P ratio의 경우 정중 과잉치와 영구 중절치는 비슷한 수치를 나타내며 통계적 유의성이 없었고, 유중절치보다는 두 그룹 모두 높게 나타났다. Ca/C ratio의 경우 마찬가지로 정중 과잉치와 영구 중절치에서 유중절치보다 높게 나타났다. 이를 통하여 정중 과잉치의 법랑질 특성은 유중절치보다는 영구 중절치와 더 유사함을 알 수 있고, 임상적으로 정중 과잉치의 활용 시 영구 중절치와 비슷한 법랑질 성질을 지님을 유추할 수 있다.

Comparative study of the radiopacity of resin cements used in aesthetic dentistry

  • Montes-Fariza, Raquel;Monterde-Hernandez, Manuel;Cabanillas-Casabella, Cristina;Pallares-Sabater, Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.201-206
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the radiopacity of 6 modern resin cements with that of human enamel and dentine using the Digora digital radiography system, to verify whether they meet the requirements of ANSI/ADA specification no. 27/1993 and the ISO 4049/2000 standard and assess whether their radiopacity is influenced by the thickness of the cement employed. MATERIALS AND METHODS. Three 3-thickness samples (0.5, 1 and 1.5 mm) were fabricated for each material. The individual cement samples were radiographed on the CCD sensor next to the aluminium wedge and the tooth samples. Five radiographs were made of each sample and therefore five readings of radiographic density were taken for each thickness of the materials. The radiopacity was measured in pixels using Digora 2.6 software. The calibration curve obtained from the mean values of each step of the wedge made it possible to obtain the equivalent in mm of aluminium for each mm of the luting material. RESULTS. With the exception of Variolink Veneer Medium Value 0, all the cements studied were more radiopaque than enamel and dentin (P<.05) and complied with the ISO and ANSI/ADA requirements (P<.001). The radiopacity of all the cements examined depended on their thickness: the thicker the material, the greater its radiopacity. CONCLUSION. All materials except Variolink Veneer Medium Value 0 yielded radiopacity values that complied with the recommendations of the ISO and ANSI/ADA. Variolink Veneer Medium Value 0 showed less radiopacity than enamel and dentin.

Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system

  • Yaylaci, Ayla;Karaarslan, Emine Sirin;Hatırli, Huseyin
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.261-269
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum. Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test(P<0.05). Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements. Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.

삭제된 법랑질의 표면거칠기에 따른 도재 라미네이트의 전단결합강도에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH OF THE PORCELAIN LAMINATE ACCORDING TO SURFACE ROUGHNESS OF THE CUT ENAMEL)

  • 박봉석;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.159-168
    • /
    • 1994
  • The purpose of this study was to evaluate the shear bond strength of the porcelain laminate specimens according to the surface roughness of the cut enamel of human anterior teeth. Flat enamel surfaces were prepared in 30 extracted human anterior teeth with diamond disc which were divided into two groups. Group 1 Coarse enamel surface group prepared with LVS-3 bur. Group 2 Fine enamel surface group prepared with superfine diamond bur. 30 teeth specimens of two group were stored in normal saline during 24 hours. 30 disk - type porcelain laminate specimens with diameter 4mm and thickness 1mm were made and sand - blasted on internal surface which were to cemented on enamel surface. Porcelain laminate specimens were cemented on enamel surface with Choice Veneer System (Bisco Dental, U.S.A) according to manufacture's instructions. All teeth specimens of two groups were manipulated with same method and stored In normal saline before testing. An Universal Testing machine (Model No.UTM-4206,Instron, U.S.A) was used to apply shear loads in the vertical directed, and the force required for separation was recorded with a cross head speed of 3mm/min and 500kg in full scale. The results were as follow ; 1. The mean shear bond strength of coarse surface group was 36.30kg and that of fine surface group was 44.39 kg, but there was no significant difference in breaking strength of two groups(p>0.05).

  • PDF

수종의 유기산이 법랑질 인공우식의 형성에 미치는 영향 (THE EFFECT OF FOUR KINDS OF ACID AND CONCENTRATION ON THE FORMATION OF ARTIFICIAL CARIOUS LESION IN HUMAN TOOTH ENAMEL)

  • 금기연;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.470-488
    • /
    • 1996
  • The end products of the metabolism of the oral microorganism, organic acids, are an element that produces dental caries. Four organic acids in plaque fluid, lactic acid, acetic acid, succinic acid, propionic acid which take the important role in producing dental caries, were chosen to evaluate the effect of acid type and concentration. The subject, $100{\mu}m$ in thickness, were immersed in acid-buffer solution which has the different acid concentration of 10mM, 25mM, 50mM, 100mM and pH 4.3 and degree of saturation was $0.153{\pm}0.003$ kept in constant and were operated to produce artificial caries under different demineralization time (1, 2, 3 day) at x25. The results were obtained by observing under polarizing microscope at x25. 1. The subsurface lesion, specific finding of incipient enamel caries, showed positive birefringence. but surface zone and sound enamel showed negative birefringence. 2. The demineralization rate of enamel was increased as the acid concentration increased. 3. The subsurface lesion showed increasing depth in the order of lactic, acetic, propionic acid, succinic acid. 4. The concentration of organic acid in artificial caries system had an independent effect on demineralization rate in enamel under the constant pH and degree of saturation. The result of this study showed that not only pH and the acid strength but the concentration of organic acid had an independent effect on demineralization rate in early enamel caries. And through the further research on the factors influencing enamel demineralization, it will be necessary to develop an effective caries preventive therapy.

  • PDF

미세 레이저 가공의 표면코팅 후 전해 에칭 (Laser Micro Machining and Electrochemical Etching After Surface Coating)

  • 김태풍;박민수
    • 한국정밀공학회지
    • /
    • 제30권6호
    • /
    • pp.638-643
    • /
    • 2013
  • Laser beam machining (LBM) is fast, contactless and able to machine various materials. So it is used to cut metal, drill holes, weld or pattern the imprinted surface. However, after LBM, there still leave burrs and recast layers around the machined area. In order to remove these unwanted parts, LBM process often uses electrochemical etching (ECE). But, the total thickness of workpiece is reduced because the etching process removes not only burrs and recast layers, but also the entire surface. In this paper, surface coating was performed using enamel after LBM on metal. The recast layer can be selectively removed without decreasing total thickness. Comparing with LBM process only, the surface quality of enamel coating process was better than that. And edge shape was also maintained after ECE.

Effect of Winding Coil Diameter on AC Insulation Breakdown Voltage of Polyamideimide/Nanosilica Wire

  • Park, Jae-Jun;Woo, Myung-Ha;Lee, Jae-Young;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권4호
    • /
    • pp.231-234
    • /
    • 2016
  • The AC insulation breakdown voltage was investigated for seven types of winding coils made of polyamideimide (PAI), flexural PAI (nanosilica 5 wt%) and anti-corona PAI (nanosilica 15 wt%) wires with various winding coil diameters of φ5, φ15 and φ25 mm. The winding coil was made of enameled wire with an enamel thickness of 30~50 μm, and the rectangular copper wire had a thickness of 0.77~ to 0.83 mm and width of 1.17~ to 1.23 mm, respectively. The insulation breakdown voltages of the original PAI coils with diameters of φ5, φ15 and φ25 mm were 7.30, 6.58, and 5.95 kV, respectively, and those values decreased as the winding coil diameter increased, regardless of the wire types.