• 제목/요약/키워드: Enamel roughness

검색결과 39건 처리시간 0.026초

리튬디실리케이트 세라믹과 표면처리방법에 따른 라미네이트 베니어의 전단결합강도 비교 (Comparison of Shear Bonding Strength of Laminate Veneer by Lithium Disilicate Ceramics and Surface Treatment Methods)

  • 박상준;정인성
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.177-185
    • /
    • 2019
  • Purpose: This study was to investigate the effect of three different surface treatments on the shear bond strength of lithium disilicate ceramics to enamel. Methods: Totally 60 lithium disilicate ceramic disc specimens were fabricated with IPS e.max press (Ivoclar Vivadent, Schaan, Liechtenstein) and Mazic Claro (Vericom, Korea). 30 specimens in each lithium disilicate ceramic were assigned to 3 groups of the each following surface treatment: 1) $50{\mu}m$ airborne particle abrasion+silane, 2) 9.5% hydroflouric acid etching (HF)+silane, 3) $50{\mu}m$ airborne particle abrasion+9.5% HF+silane. Lithium disilicate ceramic surfaces after surface treatments were AFM examined. The shear bond strength was measured in a universal testing machine at 0.5mm/min crosshead speed. All data were analyzed using a two-way ANOVA and Tukey's test(${\alpha}=0.05$). Results: The mean surface roughness of lithium disilicate ceramics ranged from $0.178{\mu}m$ to $0.441{\mu}m$. The mean shear bond strengths ranged from $23.81{\pm}2.78MPa$ to $33.99{\pm}4.85MPa$. Conclusion: 1. Mazic Claro showed higher shear bond strength than IPS e.max press at 3 different surface treatments, and no statistically significant was observed. 2. The shear bond strength of IPS e.max press was strongly enhanced as surface treated with $50{\mu}m$ airborne particle abrasion and 9.5% hydroflouric acid etching. And there was no statistical significance at the shear bond strength of Mazic Claro with surface treatments.

가시광선중합화에 따른 충전용 Glass Ionomer Cement의 물리적 성질에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES OF GLASS IONOMER CEMENT FOR RESTORATIVE FILLING USING VISIBLE LIGHT POLYMERIZATION)

  • 신동훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.307-330
    • /
    • 1992
  • The aim of this study was to investigate the physical properties of visible light curing Glass Ionomer cement for restorative esthetic filling. The control group was the autopolymerizing GC Fuji II Glass Ionomer cement (2.2: 1 P/L ratio) and the experimental groups were made by following procedure. To induce the polymerization by visible light, the powder of GC Fuji II GI cement and the liquid of Vitrabond for base & liner were mixed in an amalgam capsule with 2.5:1, 3.0:1, 3.5:1 P/L ratio (% wt/wt). After fabrication of specimens, compressive strength, fracture toughness ($K_{IC}$) Scanning Electron Microscope and X-ray Diffraction, water-leachable content, marginal leakage and surface roughness were studied. The results were as follows: 1. Only experimental No. 1 group (visible light curing) showed less compressive strength than control group 1 hour after curing. Strength was increased with aging in all groups, so the compressive strength of light curing groups was no less than that of autopolymerizing group after 3 weeks. 2. Experimental No.3 group (visible light curing) was inferior to No.2 group (visible light curing) in fracture resistance but light curing groups were more resistant to fracture than autopolymerizing group and showed ductile fracture pattern as compared with the brittle fracture pattern of autopolymerizing group. 3. From scanning electron microscopic image, various sized unreacted powder particles, surrounded by silica gel, were embedded in polysalt matrix. Light curing groups showed little crack and more dense unreacted particles than autopolymerizing group. 4. From X-ray diffraction analysis, GC Fuji II Glass Ionomer cement powder and all groups showed glassy appearance but light curing groups seemed to be more intensive in crystaline than autopolymerizing group. S. The most significant dissolution was shown in early setting period in all group. Light curing groups were dissolved less than autopolymerizing group. 6. Marginal leakage was not different significantly in case of cavity margin composed of same tooth structure (ex. only enamel margin, only dentin margin) but much more leakage was shown in dentin/cementum margin than enamel margin. In only case of only enamel margin, light curing groups were superior to autopolymerizing group. 7. All groups showed relatively smooth surface, which irregularity was less than $1{\mu}m$. Light curing groups were smoother than autopolymerizing group.

  • PDF

산성음료가 치아색 수복재의 표면에 미치는 영향 (The effect of acidic drinks on the surface of tooth-colored restorative materials)

  • 방석윤;김은정;김현정;남순현;김영진
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.469-481
    • /
    • 2006
  • 법랑질 침식의 병인 중에서 식이습관은 많은 관심을 받아왔고 특히 산성음료의 음용이 많은 주의를 끌어왔다. 산성음료의 급속한 소비량 증가는 치아뿐만 아니라 치아색 수복재료의 표면에도 많은 영향을 미칠 것으로 생각된다. 따라서 본 연구는 어린이들이 비교적 일상적으로 접하는 산성음료 중 가장 보편화된 3종을 선택하여 치아색 수복재료의 노출시간에 따른 표면의 변화를 조사할 목적으로 시행되었다. Resin-modified glass-ionomer, polyacid-modified composite resin, composite resin을 0.9% NaCl, 콜라, 오렌지 쥬스, 스포츠 음료의 각 4개 군으로 나누어 저장하였다. 저장 전과 저장 후 1일, 1-,2-,3-,4-주에 표면강도 및 표면조도를 측정하였고 다음과 같은 결론을 얻었다. 1. 산성음료에 저장했을 경우 composite resin을 제외한 치아색 수복재들은 통계학적으로 유의한 표면강도와 표면조도의 변화를 보였다(p<0.05). 2. 표면강도 및 표면조도의 변화는 resin-modified glass-ionomer, polyacid-modified composite resin composite resin 순으로 크게 나타났다. 3. 콜라나 오렌지 쥬스보다 스포츠 음료에서 표면변화는 더 크게 나타났다. 4. 산성음료에 저장한 군의 SEM 촬영에서 resin-modified glass-ionomer, polyacid-modified composite resin의 경우 충전제의 상실이 관찰되었으며 특히 resin-modified glass-ionomer의 경우 심한 균열이 관찰되었다.

  • PDF

Effect of dentin surface roughness on the shear bond strength of resin bonded restorations

  • Koodaryan, Roodabeh;Hafezeqoran, Ali;Poursoltan, Sajjad
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.224-228
    • /
    • 2016
  • PURPOSE. This study aimed to investigate whether dentin surface preparation with diamond rotary instruments of different grit sizes affects the shear bond strength of resin-bonded restorations. MATERIALS AND METHODS. The buccal enamel of 60 maxillary central incisors was removed with a low speed diamond saw and wet ground with silicon carbide papers. The polished surfaces of the teeth were prepared with four groups of rotary diamond burs with super-coarse (SC), coarse (C), medium (M), and fine (F) grit sizes. Following surface preparation, 60 restorations were casted with nickel-chromium alloy and bonded with Panavia cement. To assess the shear bond strength, the samples were mounted on a universal testing machine and an axial load was applied along the cement-restoration interface at the crosshead speed of 0.5 mm/min. The acquired data was analyzed with one way ANOVA and Tukey post hoc test (${\alpha}=.05$). RESULTS. The $mean{\pm}SD$ shear bond strengths (in MPa) of the study groups were $17.75{\pm}1.41$ for SC, $13.82{\pm}1.13$ for C, $10.40{\pm}1.45$ for M, and $7.13{\pm}1.18$ for F. Statistical analysis revealed the significant difference among the study groups such that the value for group SC was significantly higher than that for group F (P<.001). CONCLUSION. Dentin surface roughness created by diamond burs of different grit sizes considerably influences the shear bond strength of resin bonded restorations.

지르코니아의 소결 후 특성 (Surface Characteristics of Ground and Post-Sintered Zirconia)

  • 김민정;김임선;최병환;김원기
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.157-163
    • /
    • 2016
  • Purpose: It is to compare and evaluate the change of the wear rate and phase variation of the Zirconia before and after the sintering after the grinding by a high speed equipment manufactured for the Zirconia. Methods: The specimen of the sintered Zirconia was manufactured as size of $15mm{\times}15mm{\times}2mm$. The grinding has been applied to each of all pieces of each test groups for a minute fit for each condition at same speed of 50,000 rpm by a diamond bur at high speed handpiece with injection of the air and water. For the observation of the surface before and after the sintering of the each test piece, the cross section of it was observed as 100 magnification by a scanning electron microscope after it was coated by PT, and the diffraction analysis was performed by XDR to compare the crystal phase of the Zirconia. The average surface roughness value of all specimens were evaluated. The wear test was performed at room temperature by applying a load of 1kg for 120,000 cycles for the chewing period 6 months. Wear was analyzed for the enamel cusps by measurement of the vertical substance loss with a laser scanner. Conclusion: The phase variation from the tetragonal phase to the monoclinic phase was confirmed in the test group of the pre-sintered Zirconia after the grinding, and the value of the surface roughness and the wear rate was increased in experimental group.

In vitro wear behavior between enamel cusp and three aesthetic restorative materials: Zirconia, porcelain, and composite resin

  • Jang, Yong-Seok;Nguyen, Thuy-Duong Thi;Ko, Young-Han;Lee, Dae-Woo;Baik, Byeong Ju;Lee, Min-Ho;Bae, Tae-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.7-15
    • /
    • 2019
  • PURPOSE. The aim of this study was to identify the effects of three aesthetic restorative materials on the wear between tooth and restoration by a pin-on-disk manner. MATERIALS AND METHODS. Six aesthetic restorative materials were used to prepare disk specimens for wear test, which were Lava Zirconia as zirconia group, Vintage MP and Cerabien ZR as veneering porcelain group, Gradia Direct microhybrid composite containing prepolymerized fillers, Filtek Z250 microhybrid composite containing zirconia glass and colloidal silica particles, and Filtek Z350 nanocomposite as composite resin group. Vertical loss of the worn cusp, change of the surface roughness of the restoration materials, and the surface topography were investigated after wear test under 9.8-N contact load. RESULTS. The porcelain groups (Vintage MP and Cerabien ZR) caused the largest vertical loss of teeth when compared with those of the composite resin and zirconia groups, and Filtek Z250 microhybrid composite results in the second-largest vertical loss of teeth. The surface of Filtek Z350 nanocomposite was deeply worn out, but visible wear on the surface of the zirconia and Gradia Direct microhybrid composite was not observed. When the zirconia surface was roughened by sand-blasting, vertical loss of teeth considerably increased when compared with that in the case of fine polished zirconia. CONCLUSION. It was identified that microhybrid composite resin containing a prepolymerized filler and zirconia with reduced surface roughness by polishing were the most desirable restorative materials among the tested materials to prevent the two-body wear between aesthetic restorative material and tooth.

백색광 주사간섭계의 생물학적 응용 (Biological Applications of White Light Scanning Interferometry)

  • 김기우
    • Applied Microscopy
    • /
    • 제41권4호
    • /
    • pp.223-228
    • /
    • 2011
  • 백색광 주사간섭계는 다양한 시료의 표면 특성을 분석하기 위하여 널리 활용되고 있다. 이 기법은 재료공학 분야에서 오래 전부터 이용되었으며 정성적인 형상 이미지 이외에도 정량적인 3차원 결과를 제공한다. 이 기법에서는 백색광을 광원으로 이용하는데, 기준면과 측정면에서의 반사광을 합쳐서 형성되는 간섭신호를 형태 정보로 활용한다. z축 결과인 고도는 회색수준으로 구분되어 제시된다. 이 기법을 통하여 대영역으로 생물 시료를 신속하고 비파괴적으로 형태를 계측할 수 있다. 연골세포, 치아 법랑질, 식물 잎을 대상으로 적용한 사례가 있다. 특히 표면 구조물의 폭, 길이, 경사각과 같은 특성도 이 기법을 통하여 정량화할 수 있다. 이 기법을 적용하기 위하여 일정 수준의 반사도가 필요한데, 식물 잎에서의 반사도는 그 요건을 충족하였다. 전도성 금속의 코팅 등 부가적인 시료 전처리가 필요 없으므로 이 기법을 통한 생물 시료의 정량적 측정이 더욱 증가할 것으로 예상한다.

접착형 구조 금 인레이의 접착 형태, 강도 및 파절 양태에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON ADHESION PATTERN, ADHESION STRENGTH AND FRACTURE PATTERN OF THE ADHESIVE CAST GOLD INLAY)

  • 한승렬;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.64-72
    • /
    • 1994
  • Zinc Phosphate Cement hand been used for about more than 100 years in luting of cast gold inlay. But many scientists had been trying to develop the new form of luting agent because the ZPC hand shown the lack of adhesiveness on the tooth structure and the toxicity to the pulp tissue. Recently many researches about the surface treatment of the cast body are being done to increase the adhesion of cement to it. The conventional Class I gold inlays were fabricated in the 20 permanent molars. After the internal surface of the cast body was sandblasted with $Al_2O_3$ particles and was tin-plated, the inlays were cemented with adhesive cement [G I cement and resin cement(Super-Bond & $Panavia_{EX}$)] and the evaluation on the adhesion pattern, adhesive strength and the fracture pattern of the adhesive cast gold inlay was compared to that of the cast gold inlay cemented conventionally with ZPC. The results were as follows : 1. The surface roughness of the cast body was increased significantly after sandblasting with the $Al_2O_3$ particles and the tin oxide layer, which was consisted of round particles, came into being. 2. The bond strength was in the order of Super-Bond, ZPC, Fuji I, $Panavia_{EX}$ group. The group cemented with Super-Bond showed statistically greater strength than the other groups(p<0.05). 3. The group cemented with ZPC was fallen apart by principal adhesion failure and that with Fuji I was by complete adhesion failure. But the group with Super-Bond showed pricncipal cohesive failure pattern and in the group with $Panavia_{EX}$, complete cohesive fracture pattern was shown and small protion of tooth structure was fractured out with cast body and the fractured surface showed the figure just as the enamel prism. 4. Various gaps were shown at the pulpal side regardless of little gap at the side walls of the cavity in all groups. Only the Super-Bond was attached to the tooth structure and the other cements were detached from both the tooth and the cast body.

  • PDF

Biscover의 잇솔질에 따른 마모양상과 항우식 효과 (Experimental brush wear pattern and cariostatic effect of Biscover)

  • 오은주;박성수;장문주;전영미;김정기
    • 대한치과교정학회지
    • /
    • 제38권3호
    • /
    • pp.214-222
    • /
    • 2008
  • 본 연구는 Biscover를 교정학 영역에서 치아우식 예방 목적으로의 활용가능성을 평가하기 위해 Biscover의 잇솔질에 대한 마모 저항성을 평가하였으며, 인공우식용액에서의 치면 변화를 관찰하여 항우식 효과를 평가하였다. 교정치료를 목적으로 발거된 100개의 인간 소구치를 실험에 사용하였으며, 90개의 Biscover coating군과 10개의 대조군으로 분류하였다. Biscover coating 군은 잇솔질 횟수에 따라 무작위로 10개씩 9개의 군(B1 - B9)으로 분류하였으며, 대조군 역시 잇솔질 횟수에 따라 5개씩 2개의 군(C1, C2)으로 분류하였다(B1, 0; B2, 450; B3, 900; B4, 1,800; B5, 2,700; B6, 5,400; B7, 8,100; B8 & C1, 10,800; B9 & C2, 21,600 strokes). 3-body 마모 시험기를 이용해 치아 시편에 대한 잇솔질을 재현하였으며, 100 rpm의 빈도와 1.5N의 힘을 적용시켰다. Biscover 도포 후 법랑질면의 조도가 유의성 있게 감소되었고, 잇솔질 후에는 증가하였지만, 자연 법랑질보다 낮은 조도를 보였다 (p < 0.001). Biscover 도포 후 잇솔질 기간과 표면의 거칠기의 변화 사이에는 상관관계가 없었고, SEM을 이용한 표면과 단면 관찰 시 10,800회 잇솔질 후에 Biscover 층이 모두 마모된 것이 관찰되었다. 그러나, 치아를 인공우식용액에 7일간 침식하여 평가한 결과, 10,800회와 21,600회 잇솔질한 Biscover coating군에서는 매끄러운 표면이 관찰된 반면, 대조군인 자연치면은 심한 탈회가 진행된 소견을 보였다. 이상의 결과를 종합하여, Biscover 도포는 치면의 활택도를 향상시키며, 적절한 마모저항성을 가지는 것으로 평가되었다. 또한 마모에 의해 Biscover층이 제거된 후에도 자연치면에 비해 우식에 대한 큰 저항성을 가지는 것으로 평가되었으므로, 교정장치의 부착에 있어 이의 적절한 활용이 기대된다.