• 제목/요약/키워드: Emission unit

검색결과 451건 처리시간 0.026초

대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구 (A Study on the Energy Consumption and Greenhouse Gas Emission of the Detached Houses in Daegu)

  • 김유란;윤혜경;김주영;전규엽;홍원화
    • 한국주거학회논문집
    • /
    • 제22권2호
    • /
    • pp.35-42
    • /
    • 2011
  • In the energy consumption of buildings in Korea, the housing sector accounts for 53% of a total energy consumption. Although the researches of energy consumption on the new detached houses and apartment houses have been conducted numerous times, the researches of energy consumption characteristics on the existing detached houses are lack of studies. Thus in this study, the actual condition of energy consumption characteristics on the existing detached houses in Daegu city was examined, and then energy consumption unit and green house gas emission unit was compiled to present a fundamental data for an effective way of reducing energy consumption and greenhouse gas emission in the buildings. The results showed that the energy consumption for heating in the existing detached house was greater than other energy consumption and the heating energy sources were city gas and fuel oil. As the fuel oil consumption got larger, the energy consumption unit and greenhouse gas emission unit became bigger. Based on these results, it will be able to develop a plan for reducing energy and greenhouse gas emission in the existing detached houses in the future.

강제환기식 양돈시설의 암모니아 및 미세먼지 배출계수 산정 (Estimation of Particulate Matter and Ammonia Emission Factors for Mechanically-Ventilated Pig Houses)

  • 박진선;정한나;홍세운
    • 한국농공학회논문집
    • /
    • 제62권6호
    • /
    • pp.33-42
    • /
    • 2020
  • Emission factors for ammonia and particulate matters (PMs) from livestock buildings are of increasing importance in view of the environmental protection. While the existing emission factors were determined based on the emission inventory of other countries, in situ measurement of emission factors is required to construct an accurate emission inventory for Korea. This study is to report measurements of ammonia and PMs emissions from mechanically-ventilated pig houses, which are common types of pig barns in Korea. Ventilation rates and concentrations of ammonia and PMs were measured at the ventilation outlets of a weaner unit, a growing pig unit and a fattening pig unit to calculated the emission factors. The PMs emission was characterized with different aerodynamic diameters (PM2.5, PM10, and total suspended particulates (TSP)). The measured ammonia emission factors for weaners, growing pigs and fattening pigs were 0.225, 0.869 and 1.679 kg animal-1 yr-1, respectively, showing linear increase with pigs' age. The PMs emission factors for three growing stages were 0.023, 0.237 and 0.241 kg animal-1 yr-1, respectively for TSP, 0.017, 0.072 and 0.223 kg animal-1 yr-1, respectively for PM10, and 0.011, 0.016 and 0.151 kg animal-1 yr-1, respectively for PM2.5. PMs emissions were increased with pigs' age due to increasing feed supply and animal movement. The measured emission factors were smaller than those of the existing emission inventory indicating that the existing ones overestimate the emissions from pig buildings and also suggesting that long-term in situ monitoring at various livestock buildings is required to construct the accurate emission inventory.

수돗물의 탄소 배출량 평가 (Carbon Emission Evaluation of Tap Water)

  • 김진근;전홍진
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.511-517
    • /
    • 2011
  • To evaluate carbon emission in water treatment processes, LCA (life cycle assessment) was applied to 8 multi-regional water treatment plants (WTPs) from intake to supply of tap water. Investigation of 8 WTPs revealed that average carbon emission for 1 $m^3$ of tap water was 221 g. Major carbon emission sources in water supply system were intake and supply processes. Meanwhile, mixing process was the main carbon emission source in unit water treatment processes. Carbon emission was proportional to the turbidity and COD of raw water. Intake of better raw water and minimization of energy consumption in unit processes are needed to reduce carbon emission in the WTPs. In addition, comparison of carbon emission among WTPs can be used as a parameter for optimization of operation and maintenance of water treatment processes.

철근 생산과정의 에너지 사용량 및 CO2배출량 산출에 관한 연구 (A Study on Energy Consumption and Estimation of CO2 from Re-bar Production)

  • 최재휘;이동훈;권기덕;김선국
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.101-109
    • /
    • 2010
  • As global warming progresses, nations around the world are trying to reduce emission of $CO_2$ that accounts for the greatest portion of greenhouse gases. To reduce $CO_2$ emission, it is first necessary to estimate $CO_2$ emission of each industry. Government authorities estimate basic unit of $CO_2$ emission from re-bar that is one of the key materials of construction industry with LCA technique (Life Cycle Assessment). However, basic unit of $CO_2$ emission varies from organization to organization. The Ministry of Land, Transport and Maritime Affairs (2004) publishes it 3.48($TCO_2/ton$) and 0.30($TCO_2/ton$) with input-output analysis while the Korea Environmental Industry & Technology Institute (2008) defines it as 0.34($TCO_2/ton$) with process analysis, which indicates ambiguity in application of basic unit of $CO_2$emission. Based on the analysis of conventional methods used for estimating the $CO_2$ emission, therefore, this research suggests existing problems on the methods and focuses on proposing an strategy to effectively estimate the basic unit of $CO_2$ emission according to the energy consumption limited to the re-bar production in steel mill in order to overcome the problems. The result of this research is expected to be helpful in calculating and reducing $CO_2$ emission.

인터페이스 회로를 적용한 디젤기관의 배출가스특성에 관한 실험적 연구 (An Experimental Study on Diesel Engine of Exhaust Emission Characteristics by Interface Unit)

  • 한영출;김대열;백두성
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.104-111
    • /
    • 2003
  • In order to collect the engine performance data and determine optimum engine conditions, engine performance test based on interface unit were tested This paper was carried out that engine' performance was developed using interface unit between personal computer and diesel engine. The results of the study are summarized as follows: Interface unit was developed. By using PAL, simulation was carried in order to logic's inspection. From this tea NO$_{x}$ were decreased, otherwise PM were increased. By using EGR system PM were increased by twice in the high load ranges, it was not seen to come into effect in the low load ranges. This system was tested D-l3 mode, the results were decreased more than 50% in the NO$_{x}$ emission.

스마트 고로슬래그미분말 혼입 콘크리트의 CO2 배출량 평가에 관한 연구 (The Analysis of CO2 Emission Assessment in Concrete with Smart Blast Furnace Slag)

  • 김태형;태성호;하성균;박정훈;노승준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.43-45
    • /
    • 2012
  • As a part of recent CO2 emission reduction studies in the concrete industry with active use of concrete admixtures with low basic unit of CO2 emission such as blast furnace slag (BFS), basic unit of CO2 emission by SBFS was computed in order to assess CO2 emission by reinforced concrete building with smart blast furnace slag (SBFS). In addition, SBFS concrete was applied to the subject building for assessment of CO2 emission during material production step among construction steps. Life cycle CO2 emission assessment on the subject building was classified into 7cases according to mix ratio of BFS and SBFS.

  • PDF

건축물 전과정 $CO_2$ 평가를 위한 BIM 라이브러리 개발 (The Development of BIM Library for Building Life Cycle CO2 Assessment)

  • 이병호;홍성욱;신성우
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권2호
    • /
    • pp.67-76
    • /
    • 2012
  • BIM and its quantity take-off widely apply to the construction projects and LCCO2 Assessment using the BIM's quantity take-off function can be tried recently. Because BIM modeling programs such as Revit and ArchiCAD do not provide adequate library for LCCO2 Assessment, quantity take-off data should be conversed and applied to Carbon Emission Coefficient using Excel program or manual work. Therefore, the purpose of this research is 1) to propose the Unit Conversion Systems for Carbon Emission Coefficient, 2) to provide basic library sets for BIM based LCCO2 Assessment method, and 3) to apply 11 material library sets on a apartment unit plan modeling to pursue the CO2 emission evaluation of the material production in the process of LCCO2 Assessment. Research results showed CO2 emission amount of 458.64kgCO2/m2 from the apartment unit plan modeling.

전과정목록 분석을 이용한 전동차의 구체 재질에 따른 $CO_2$ 배출량에 관한 연구 (A Study on $CO_2$ Emissions with the Carbody Material of Electric Motor Unit (EMU) using Life Cycle Inventory Analysis (LCIA))

  • 김용기;천윤영;이재영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1123-1125
    • /
    • 2006
  • As Kyoto protocol has been effective in 2005, the reduction of $CO_2$ emission is a global urgent problem. In Korea, the $CO_2$ emission of transportation increases continuously, which can be solved partially by the use of railroad. Therefore, it is necessary to calculate exactly the $CO_2$ emission of railroad through life cycle approach. In this study, the $CO_2$ emission of electric motor unit (EMU) was evaluated with its carboy material using life cycle inventory analysis (LCIA). Among the life cycles of EMU, $CO_2$ emission was the highest in the running phase. As the total weight of EMU was lowered, $CO_2$ emission was reduced. In conclusion, the light-weighting of EMU can reduce $CO_2$ emission efficiently.

  • PDF

대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구 (A study on the Energy Consumption and the Greenhouse gas Emission intensity of Detached Houses in Daegu)

  • 김주영;김유란;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to provide a fundamental data for reducing energy consumption and greenhouse gas emission of detached houses by investigating the energy consumption characteristic of detached houses in Daegu. Although the ratio of the detached houses decreases, the detached houses are common dwelling form next to apartments. Nevertheless the study about the energy consumption of detached houses has been insufficient compared apartments. There is a necessity which will investigate the energy consumption characteristic of detached houses. Because that with the building quality which is various form is different from apartments. This study investigate construction and equipment conditions and analyzing effective factors on energy consumption of detached houses. And this study draw up the energy consumption unit and emission factors unit for greenhouse gas of detached houses. This study represent a basic report for energy consumption reduction and helps effective use of energy.

  • PDF

철골조와 벽식조 공동주택의 환경영향 비교 연구 (A Comparison of Embodied Energy and Environmental Impacts between the Steel-Structured and Wall-typed Apartment Housing)

  • 이강희
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.83-91
    • /
    • 2004
  • In a planning stage, the assessment system is required to select the proper alternative, reflected the environmental affects such as energy, $CO_2$ and $SO_x$. Unit of energy consumption, $CO_2$ emission and $SO_x$ emission among various assessment systems could be effectively utilized to select the better alternative among various building types. But researches for these areas has not been conducted systematically, but limitedly and sporadically. In this paper, it aimed at providing the unit of energy consumption, $CO_2$ emission and $SO_x$ emission to evaluate the environmental affects between the steel-structured apartment building and wall-typed apartment building. For this, the input-output analysis could be utilized in the construction stage with two-type apartment housing. This approach can be utilized to compare the various alternatives in aspect of the energy consumption and the environment affect, and to select the relatively better alternative. This study found that the unit of energy, $CO_2$ and $SO_x$ of the steel-structured apartment building is lower than that of the wall-typed building