• Title/Summary/Keyword: Emission factors

Search Result 924, Processing Time 0.025 seconds

A Study on the Reduction of $NO_x$ Emission from Dual Fuel Engine for Co-generation System (열병합발적용 Dual Fuel Engine의 질소산화물 배출저감에 관한 연구)

  • 정일래;김용술;심용식
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.31-40
    • /
    • 1991
  • This study shows the correlation between $NO_x$ emission in the exhaust gas and various operation factors of dual fuel engine for Co-generation system. General tendency was shown that the thermal efficiency was lowered by the change of operation factors. However these were not confirmed on this experiment. Increasing T4 temperature (exhaust gas temperature at turbo-charger inlet) reduces $NO_x$ emission rate. The higher T4 temperature requires lower excess air as the excess air ratio is controlled by T4 temperature on gas mode operation. Another tendency was that $NO_x$ emission rate is reduced in case of increasing boost air temperature, quantity of pilot oil or bypassing flue gas through the exhaust gas boiler. The diameter of the fuel injection nozzle was changed smaller than design value and the injection timing was readjusted. Thus $NO_x$ emission rate could be reduced as retarding injection timing and changing hole diameter of fuel injection nozzle, however maxium engine out-put was decreased by changing fuel nozzle on the diesel mode operation.

  • PDF

Emission Characteristics of PMs and Heavy Metals from Industrial Hazardous Waste Incinerators (산업 폐기물 소각시설의 입자상 물질 및 중금속의 배출특성)

  • 유종익;이성준;김기헌;장하나;석정희;석광설;홍지형;김병화;서용칠
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.213-221
    • /
    • 2002
  • The emission characteristics of particulate matter (PMs) and heavy metals from hazardous industrial wast incinerators were investigated. The particle size distribution (PSD) of PM-10 showed different patterns for two tripes of incinerators; stoker and rotary kiln. However both types showed bimodal form at inlet of air pollution control devices (APCD) and each peak (mode) is located at smaller than 1 ${\mu}{\textrm}{m}$ and near 10 ${\mu}{\textrm}{m}$. It could explain the growth of fine PM by nucleation/coagulation/condensation of metal vapors for fine mode. The PSD of PM-10 after APCD was also influenced by APCD types that had different collection mechanism, and both electrostatic precipitator and bag filter showed less collection efficiency for particles ranged from 0.2 to 0.4 ${\mu}{\textrm}{m}$ and led to a mode in the range of 0.2 to 0.8 ${\mu}{\textrm}{m}$. However the hag filter showed two modes of PSD, while the electrostatic precipitator had one peak. The PMs and heavy metals emission factors, the representative value of emission quantity for sources, for tested facilities were developed. The emission factor of uncontrolled total PM and PM-10 were 14.7 and 7.05 kg/ton waste, respectively. The emission factors from this study were a little bit different with those from US EPA AP-42. It may thus be appropriate to use these results in the course of developing national emission factors.

A Research on the Status of Greenhouse Gas Emission Factors from Livestock Sector to Create a National Greenhouse Gas Inventories (국가 온실가스 인벤토리 축산부문 작성을 위한 온실가스 배출계수 개발 현황에 관한 연구)

  • Lee, Jin Eui;Lee, Hyun Ju;Park, Kyu Hyun;Choi, Byong Yang;Ra, Chang Six
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.21-34
    • /
    • 2011
  • In this study, researches on the development of country specific greenhouse gas measurement and sampling methods from the livestock sector were reviewed. Research on greenhouse gas emission factors was started in early 2000 but was not actively involved in the development of livestock sector based emission factor: since 2009, works are underway for the development of livestock sector based emission factor. Most of the research on greenhouse gas emission in the field of animal studies were done by National Institute of Animal Science, because of the uniqueness of the research laboratories. Methods of emission measurement are still not internationally certified and therefore, measurement and sampling methods for Korea livestock sector are being studied, consulting the worldwide research trends. Flux chamber method are commonly using in Korea for green house gas emission factors measurement. In recent years, continuous measurement of the microclimate was introduced to measure greenhouse gases from livestock manure storage facilities and the micrometeorology method should be adapted as recommended by Intergovernmental Penal on Climate Change (IPCC) Guideline.

Validity Analysis of the Fine Particle Emission Calculating by Cars (자동차 미세먼지 배출량 산정의 타당성 분석)

  • Lee, Im Hack;Kim, Jin Sik;Lee, Seungjae;Kim, Shin Do
    • Applied Chemistry for Engineering
    • /
    • v.25 no.2
    • /
    • pp.222-226
    • /
    • 2014
  • In this study, the purposes are investigating and analyzing car emission factors for estimating road emissions and the legal framework for the control of particulate matters. At the result, when input emission data are not realistic, the modeling output concentration distributions can lead to a serious distortion of the results. So, the spatial analysis of the dust emission vehicles have to be based on the actual traffic volumes. Because dust emission factors used in the car by National Institute of Environmental Research Method (2010) are mainly targeted for 2003-2007 cars these could not reflect the effect of DPF and the dust emission of gasoline passenger car. So, the real dust emission factors of diesel and gasoline cars need to be developed.

Developing N2O Emission Factor in Red Pepper Fields to Quantify N2O Emission of Agricultural Field

  • Kim, Gun-Yeob;Park, Woo-Kyun;Lee, Jong-Sik;Jeong, Hyun-Cheol;Lee, Sun-Il;Choi, Eun-Jung;Kim, Pil-Joo;Seo, Young-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.598-603
    • /
    • 2014
  • The level of nitrous oxide ($N_2O$), a long-lived greenhouse gas, in atmosphere has increased mainly due to anthropogenic sources, especially application of nitrogen fertilizers. Quantifying $N_2O$ emission in the agricultural field is essential to develop National inventories of greenhouse gases (GHGs) emission. The objective of this study was to develop emission factor to estimate direct $N_2O$ emission from agricultural field by measuring $N_2O$ emissions in the red pepper cultivating field from 2010 to 2012. Emission factor of $N_2O$ calculated from accumulated $N_2O$ emission, nitrogen fertilization rate, and background $N_2O$ emission was $0.0086{\pm}0.00043kg$ $N_2O-N\;kg^{-1}$ N resulted from three year experiment of the research sites. More extensive studies need to be conducted to develop $N_2O$ emission factors for other upland crops in the various regions of Korea because $N_2O$ emission is influenced by many factors including climate characteristics, soil properties, and agricultural practices.

Analysis of Greenhouse Gas Research Trends of Hydropower Dams: Focusing on Foreign Cases (수력발전댐에서 온실가스 연구 동향 분석 : 국외 사례를 중심으로)

  • Park, Kyoung-deok;Jo, Won Gi;So, Yoon Hwan;Kang, Dong-hwan
    • Journal of Environmental Science International
    • /
    • v.31 no.2
    • /
    • pp.195-213
    • /
    • 2022
  • This research summarizes the generating factors of greenhouse gas (carbon dioxide, methane, nitrous oxide) in hydropower dams and related domestic/foreign researches. Microorganisms and eutrophication are the main factors in greenhouse gases in hydropower dam reservoirs. The greenhouse gas emission from the hydropower dam is affected by meteorological factors and dam operation periods, and greenhouse gases are also emitted from the outlets. The fluxes of greenhouse gas emission from the hydropower dams were -926~180,806 mg CO2 m-2d-1, -0.19~3800 mg CH4 m-2d-1, and 0.01~16.1 mg N2O m-2d-1. In South Korea, the study on the greenhouse gas emission from Korean hydropower dams has been rarely, and therefore it is inquired. This research suggested the methods on the greenhouse gas emission from Korean hydropower dams and flux calculation.

An Estimation of Age-, Power-, and Type-Specific Emission Inventories for Construction Equipments Using Improved Methodologies and Emission Factors (배출계수 개발 및 배출량 산정 체계 고도화를 통한 건설기계의 연식, 출력 및 기종별 대기오염물질 배출량 산정)

  • Jin, Hyungah;Lee, Taewoo;Park, Hana;Son, Jihwan;Kim, Sangkyun;Hong, Jihyung;Jeon, Sangzin;Kim, Jeongsoo;Choi, Kwangho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.555-568
    • /
    • 2014
  • The construction equipment is one of the major sources for hazardous air pollutants in Korea, and the its management has been of great concern recently. The objective of this study was to estimate each contribution of emission of construction equipments according to their production year, electric power consumption and type. To achieve this goal, we developed pollutant emission factors for the machineries manufactured after 2009, which are excluded from the present framework of Korean air pollutants inventory, CAPSS. More than 800 data obtained from emission investigations were utilized for the estimation. Compared with the previous estimation, the scheme used this study was modified to incorporate new emission factors as well as to include the corresponding activity data. Such improvement allow us to gain more detailed emission informations which are better characterized by specifications of construction equipments. The total amount of pollutants emitted from construction equipments in 2011 were estimated as 126.8, 7.0, 58.3, and 17.0 kton for $NO_x$, PM, CO, and VOC, respectively. The estimation results indicate that the increase in the emission of equipments is significantly related to their age and power consumption. The emissions of the older ones manufactured from 1992~1996 were estimated to be the contribution ranged from 23.7% to 26.8%, whereas the newer ones (2009~2011) showed the attributions of 11.3~21.5%. In addition, the results show that the emission of each equipment was increased with the increase in the electric power consumption of engine, probably due to their average output power. Among the nine types of machinery compared, excavators and forklifts were investigated to contribute relatively higher emissions in the level of 39.8~44.0% and 32.0~34.2%, respectively.

A Study on Emission Characteristics of Air Pollutants from the use of Solid Fuel (고체연료 사용에 따른 오염물질 배출특성 조사연구)

  • Kim, Jong-Hyeon;Heo, Sun-hwa;Kim, Hyung-Chun;Jo, Myeong-ran;Lim, Seungy-oung;Lee, Sang-Bo;Kang, Dae-il
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.2
    • /
    • pp.77-86
    • /
    • 2017
  • Globally, use of affordable fuels such as briquettes, woods and wood pellets has increased. Organic pollutants emitted from non-point sources using solid fuels may have contributed to air pollution in urban environment. In this study, we utilized simulated incinerator proposed by U.S. EPA and investigated concentrations of PM, $PM_{10}$, $PM_{2.5}$, OC/EC, CO, $SO_x$, $NO_x$, VOCs and PAHs emitted while cooking meat and fish using briquettes, woods and wood pellets, and developed emission factors. As a result, wood combustion produced more air pollutants than the others. Particulate matter emission factors for woods and wood pellets were 13.54 g/kg and 9.15 g/kg, respectively. Total VOCs emission factors for briquettes, woods and wood pellets were 36.12mg/kg, 46.13mg/kg and 18.26mg/kg, respectively. Additionally, total PAHs emission factors for briquette, woods and wood pellets were 0.44 mg/kg, 18.84mg/kg and 101.62mg/kg, respectively.

Priority for Developing Emission Factors and Quantitative Assessment in the Forestry Sector (산림부문의 국가온실가스 배출·흡수계수 개발 필요 우선순위 및 정량평가 방법론)

  • Han, Seung Hyun;Lee, Sun Jeoung;Chang, Hanna;Kim, Seongjun;Kim, Raehyun;Jeon, Eui-Chan;Son, Yowhan
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.239-245
    • /
    • 2017
  • This study aimed to suggest priority for developing emission factor (EF) and to develop the methodology of quantitative assessment of EF in the forestry sector. Based on the stock-difference method, 17 kinds of EFs (27 EFs based on forest types) were required to calculate the carbon emission in the forestry sector. Priority for developing EFs followed the standards, which is a development plan by the government agency, importance of carbon stock for greenhouse gas, and EFs by the species. Currently, the most urgent development of EFs was carbon fraction in biomass and carbon stock in dead wood. Meanwhile, the quantitative assessment of EF consisted of 7 categories (5 categories of compulsory and 2 categories of quality evaluation) and 12 verification factors. Category in compulsory verification consisted of administrative document, determination methodology of emission factors, emission characteristic, accuracy of measurement and analysis, and data representative. Category in quality evaluation consisted of data management and uncertainty estimates. Based on the importance of factors in the verification process, each factor was scored separately, however, the score needs to be coordinated by the government agency. These results would help build a reliable and accurate greenhouse gas inventory report of Korea.

The Study on the Emission Characteristics of HAPs and PM from the Motor Vehicle Paint Facility (자동차 도장시설에서 발생하는 유해대기오염물질 및 미세먼지의 배출특성에 관한 연구)

  • Kim, Han-Na;Bong, Choon-Keun;Kim, Yong-Gu;Jeon, Jun-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.713-721
    • /
    • 2013
  • This study is about emission characteristics of HAPs and particulate matters emitted by spray of paint and organic solvent usually used in vehicle paint facilities. To analyze emission characteristics of HAPs and particulate matters emitted from vehicle paint facilities are calculated based on the measuring emission quantity of pollutants based on the amount of paint used (kg) and unit area ($m^2$) by paint manufacturers (J company, K company, and R company). In cases of paint manufacturers (J, K, and R), average emission factors of VOCs, carbonyl compound, particulate matter, and PAHs per 1 kg of paint were 327.81 g/kg, 5.98 g/kg, 336.70 g/kg, and 0.0078 g/kg respectively. The average emission factors of VOCs, carbonyl compounds, particulate matters, and PAHs by unit area were $171.55g/m^2$, $3.10g/m^2$, $176.27g/m^2$, and $0.0036g/m^2$ respectively.