• Title/Summary/Keyword: Emission Control

Search Result 1,564, Processing Time 0.026 seconds

Countermeasures to the Introduction of Low Caloric Gas Fuel for Natural Gas Engine (저열량 가스 적용에 따른 천연가스엔진의 대응 방안 연구)

  • Park, Cheol-Woong;Kim, Chang-gi;Oh, Se-Chul;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.2
    • /
    • pp.34-41
    • /
    • 2021
  • In order to cope with the problems that may occur when the natural gas used in Korea becomes low in calories, the problems that may have to the domestic industrial gas equipment must be identified in advance, and based on this, countermeasures for efficient use of energy must be preceded. In this study, in order to solve the problem of deterioration of engine output performance and efficiency due to the introduction of low calorific gas when using a lean-burning natural gas engine that complies with the EURO-6 regulation, specific control plans and results based on the experiment are intended to be presented. In order to identify the improvement effect by the control variable represented by the ignition timing under the full load condition at the engine speed of 1,400 rpm and 550 Nm, 2,100 rpm, which is the engine speed at the rated operation condition, the thermal efficiency and exhaust gas characteristics were identified and optimized by changing the ignition timing for each gas fuel. In the case of pure methane, which shows the lowest value based on the torque under the full load condition, if the ignition timing is advanced by about 2 CAD from the reference ignition timing, the torque can be compensated without a large increase in NOx emission.

Concentration of Heavy Metals, Residual Pesticides and Sulfur Dioxide of before/after a Decoction - In Prescription of Digestive System - (전탕 전과 후의 중금속, 잔류농약 및 잔류이산화황의 농도변화 - 소화기계 약을 중심으로 -)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.24 no.1
    • /
    • pp.111-119
    • /
    • 2009
  • Objectives : To compare the contents of hazardous substances before/after a decoction. Methods : The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 6 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide (SO2) were performed by Monier-Williams distillation method. Results : 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Samchulkunbi-tang (before decoction - Pb; 1.592, Cd; 0.155, As; 0.055 and Hg; 0.014, after decoction - Pb; 0.036, Cd; 0.002, As; not detected and Hg; 0.001), Yijin-tang (before decoction - Pb; 0.830, Cd; 0.077, As; 0.045 and Hg; 0.015, after decoction - Pb; 0.193, Cd; 0.010, As; not detected and Hg; 0.002), Banhabaikchulcheunma-tang (before decoction - Pb; 0.976, Cd; 0.164, As; 0.167 and Hg; 0.019, after decoction - Pb; 0.031, Cd; 0.003, As; 0.006 and Hg; 0.005), Pyungwi-san (before decoction - Pb; 2.162, Cd; 0.128, As; 0.061 and Hg; 0.018, after decoction - Pb; 0.080, Cd; 0.006, As; not detected and Hg; 0.005), Leejung-tang (before decoction - Pb; 1.480, Cd; 0.294, As; 0.034 and Hg; 0.012, after decoction - Pb; 0.064, Cd; 0.007, As; 0.007 and Hg; 0.002) and Kwibi-tang (before decoction - Pb; 0.907, Cd; 0.193, As; 0.085 and Hg; 0.020, after decoction - Pb; 0.072, Cd; 0.006, As; 0.004 and Hg; 0.002). 2. Contents (mg/kg) of sulfur dioxide ($SO_2$) before a decoction in Banhabaikchulcheunma-tang, Pyungwi-san, Leejung-tang and Kwibi-tang exhibited 3.5, 3.4, 3.8 and 12.4, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. 3. Contents (mg/kg) of residual pesticides before/after a decoction in all samples were not detected. Conclusions : These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

Effects of Dietary Germanium Biotite on Growth Performance and Blood Characteristics in Broiler Chicks (육계에 있어 게르마늄 흑운모의 첨가가 성장 및 혈액성상에 미치는 영향)

  • 이원백;김인호;홍종욱;권오석;민병준;손경승;정연권
    • Korean Journal of Poultry Science
    • /
    • v.30 no.1
    • /
    • pp.67-72
    • /
    • 2003
  • This study was conducted to investigate the effect of germanium biotite on the growth performance, blood composition , fecal NH$_3$-N and volatile fatty acid(VFA) in broiler chicks. Two hundred forty broiler chicks were randomly allocated into five treatments with four replicates for five weeks. Dietary treatments included 1) Control, 2) GB1(basal diet + 200 mesh 0.5%), 3) GB2(basal diet + 325 mesh 0.5%), 4) GB3(basal diet + 200 mesh 1.0%) and 5) GB4(basal diet +325 nesh 1.0%) For overall period, weight gain, feed intake and feed conversion were not significantly different among treatments (P>0.05). Digestibilities of nutrients were not affected by adding GB(P>0.05). No differences occurred in red blood cell(RBC), white blood cell(WBC), hematocrit(HCT), hemoglobin(Hb), lymphocyte, monocyte and platelet of blood among the treatments (P>0.05). Fecal NH$_3$-N concentration of chicks fed GB1.0 diets(GB3 and GB4) was lower(P<0.03) than chicks fed GB0.5 diets(GB1 and GB2). Propionic acid and butyric acid in feces of chicks fed GB diets were lower(P<0.04) than in chicks fed control diet. GB diets reduced fecal acetic acid significantly compared to control (P<0.01). Also, acetic acid of feces in chicks fed GB1.0 diets(GB3 and GB4) was lower(P<0.02) than GB 0.5 diets(GB1 and GB2) treatments. In conclusion, dietary germanium biotite was an effective means of decreasing fecal NH$_3$-N and volatile fatty acid(VFA) emission.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Effects of Feeding Mushroom Substrate Waste and Probiotics on Productivity, Emission of Gases and Odors in Manure for Finishing Pigs (버섯재배 폐배지와 생균제의 급여가 비육돈의 생산성, 돈분 중 가스 및 냄새발생에 미치는 영향)

  • Choi, S.C.;Chae, B.J.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.529-536
    • /
    • 2003
  • A total of 72 finishing pigs(L${\times}$Y${\times}$D; 80kg of initial body weight) were employed for 5 weeks to investigate the effects of feeding mushroom substrate waste(MSW) treated with pleurotus ostreatus and probiotics on productivity, carcass traits, nutrient digestibility and emissions of harmful gases and malodor in manure. Treatments were Control(C: basal diet), T1(3% MSW) and T2(3% MSW+ 0.1% probiotics). Average daily gain(ADG) was lower(p<0.05) in pigs fed a T1 diet than those fed a C diet, however, there was no difference in ADG of pigs fed diets between C and T2. Similar trends were found in feed/gain(F/G) among treatments, though feed intake was not different. No differences were found in back fat thickness among treatments, but carcass dressing percentage was significantly(p<0.05) improved in pigs fed a T2 diet compared to C or T1 diets. Nutrient digestibilities including dry matter, crude protein, energy and crude fiber were lower(p<0.05) in T1 than C or T2. $NH_3$ and $H_2S$ gas emissions were reduced(p<0.05) or not produced in pig manure from T2 as compared to C or T1. In conclusion, the present result shows that feeding MSW with probiotics is desirable for finishing pigs in terms of productivity, carcass traits and nutrient digestibility. It also appears that the emission of harmful gases and malodor in manure can be reduced by the inclusion of probiotics in the diet.

Effects of Dietary Kaolin on the Performance, Product Quality and Feeding Environment of Growing Ducks (고령토를 첨가한 사료의 급여가 육용오리의 능력과 생산물의 품질 및 사육환경에 미치는 영향)

  • Lee W. J.;Lee K. H.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.2
    • /
    • pp.81-87
    • /
    • 2005
  • A study was carried out to examine the effects of dietary kaolin on the performance, feed and nutrient efficiency, meat quality and feeding environment using 200 day-old growing ducts. Four replicates of 10 birds each was assigned to diets containing 0(C), 1 (T1), 2(T2), 3(T3) and $4(T4)\%$ of kaolin. Body weight gain in T1 and T2 were higher than in $C(p<0.05)$ whereas weight gain in T3 and T4 were not significantly different from the control. Feed intake and feed conversion ratio tended to increased as the level of dietary kaolin increased, but without significant differences among treatments. Mortality of growing ducks during 6 week period was not significantly different among treatments. Dressing percentage was highest in T1 and lowest in T4 $(p<0.05)$. The utilizability of nutrients except for crude fat Increased$(p<0.05)$, as the level of dietary kaolin increased. Moisture content and $NH_3$ gas emission of excreta was not significantly influenced by dietary kaolin. $H_2S$ gas emission of excreta in T2, T3 and T4 was lower compare to that in C and $T1(p<0.05)$. Cholesterol content in breast and thigh meat was not different among treatments. Values for pH, WHC, TBARS, POV and Cooking loss of breast and thigh meat were not significantly different or did not show any trend among treatments.

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Evaluation on Cooling Effects of Geothermal Heat Pump System in Farrowing House (지열 냉방시스템을 이용한 분만돈사의 냉방효과 분석)

  • Choi, H.C.;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.;Park, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.99-108
    • /
    • 2010
  • The principal objective of this study was to investigate the cooling effects of geothermal heat pump system (GHPS) in farrowing house. A total of 96 sows were allocated to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in summer season. During the experimental period of four weeks, the highest outside temperature observed was approximately $34.1^{\circ}C$, GHPS decrease indoor temperature of pig housing up to $30.9^{\circ}C$, but conventional pig housing was similar to outside temperature. Dust concentrations (maximum 61.4%) of particulate matter less than $10{\mu}m$ (PM 10) in GHPS-housing were lower than the conventional housing. GHPS showed no signigicant difference in carbon dioxide emission, whereas the ammonia gas concentration was significantly decreased in GHPS-housing compared to that of conventional housing. Sows in GHPS-housing showed significantly lower respiratory rate than those of the control group. GHPS did not affect hormone level, litter size and birth weight, but weaning weight of piglets was influenced by GHPS. Feed consumption of sows was significantly increased in GHPS-housing compared to the conventional hosing. These results suggest that GHPS decrease dust concentration, ammonia gas emission and indoor temperature of pig housing and may affect performance in sows and weaned piglets.

Assessment of Climate Change Impact on Storage Behavior of Chungju and the Regulation Dams Using SWAT Model (SWAT을 이용한 기후변화가 충주댐 및 조정지댐 저수량에 미치는 영향 평가)

  • Jeong, Hyeon Gyo;Kim, Seong-Joon;Ha, Rim
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1235-1247
    • /
    • 2013
  • This study is to evaluate the climate change impact on future storage behavior of Chungju dam($2,750{\times}10^6m^3$) and the regulation dam($30{\times}10^6m^3$) using SWAT(Soil Water Assessment Tool) model. Using 9 years data (2002~2010), the SWAT was calibrated and validated for streamflow at three locations with 0.73 average Nash-Sutcliffe model Efficiency (NSE) and for two reservoir water levels with 0.86 NSE respectively. For future evaluation, the HadCM3 of GCMs (General Circulation Models) data by scenarios of SRES (Special Report on Emission Scenarios) A2 and B1 of the IPCC (Intergovernmental Panel on Climate Change) were adopted. The monthly temperature and precipitation data (2007~2099) were spatially corrected using 30 years (1977~2006, baseline period) of ground measured data through bias-correction, and temporally downscaled by Change Factor (CF) statistical method. For two periods; 2040s (2031~2050), 2080s (2071~2099), the future annual temperature were predicted to change $+0.9^{\circ}C$ in 2040s and $+4.0^{\circ}C$ in 2080s, and annual precipitation increased 9.6% in 2040s and 20.7% in 2080s respectively. The future watershed evapotranspiration increased up to 15.3% and the soil moisture decreased maximum 2.8% compared to baseline (2002~2010) condition. Under the future dam release condition of 9 years average (2002~2010) for each dam, the yearly dam inflow increased maximum 21.1% for most period except autumn. By the decrease of dam inflow in future autumn, the future dam storage could not recover to the full water level at the end of the year by the present dam release pattern. For the future flood and drought years, the temporal variation of dam storage became more unstable as it needs careful downward and upward management of dam storage respectively. Thus it is necessary to adjust the dam release pattern for climate change adaptation.