• 제목/요약/키워드: Emergency monitoring

검색결과 469건 처리시간 0.024초

원자력발전소 비상디젤발전기 상태감시 기술 적용 연구 (Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant)

  • 최광희;박종혁;박종은;이상국
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

USN기반 자율무선통신방식 비상등관리시스템 제안 (The Proposed of Emergency Light Monitoring System by Self-Organization Radio Communication based on USN)

  • 최재명;강희조;이상헌
    • 한국항행학회논문지
    • /
    • 제13권2호
    • /
    • pp.252-256
    • /
    • 2009
  • 본 논문에서는 산재되어있는 비상등을 운용관리센터에서 항시 점검 및 관리할 수 있고, 데이터 병목현상에 구애받지 않는 안정된 데이터 통신이 가능한 클러스터 구조형 감시망을 이용하여 비상등감시장치를 설치함에 있어 비상등 위치에 구애받음 없이 비상등의 감시장치를 설치할 수 있고, 감시 통신망을 구축함에 있어 게이트웨이로 지정된 감시장치가 고장나더라도 사각지대 없이 비상등의 상태를 감시 및 관리가 가능한 비상등관리시스템을 제안한다.

  • PDF

원자력발전소 비상디젤발전기 상태감시를 위한 운전인자 선정에 관한 연구 (Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant)

  • 박종혁;최광희;이상국;박종은
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.3-8
    • /
    • 2007
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear reactor at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the plant safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to maintain and monitor and forecast the reliability level of diesel generator. To do this kind of diesel generator condition monitoring we reviewed several operating factors and history of the wolsong unit 3 diesel generator and selected the proper conditioning monitoring operating factors.

  • PDF

액체로켓엔진 상태진단/비상보호시스템 연구 (Study on the Liquid Rocket Engine Health Monitoring and Emergency Protection System)

  • 김승한;남창호;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.178-182
    • /
    • 2007
  • 액체로켓엔진시스템 개발 시험 중 발생할 수 있는 각종 이상 징후 발생 시 이를 사전에 감시하고, 비상상황 발생 시 시험대상 엔진과 시험설비를 보호하기 위한 엔진 상태진단 및 비상보호시스템에 대해 살펴보았다. 비상보호시스템의 일반적인 구성과 관련된 주요 기술 고려사항을 검토하였다. 또한, 터보펌프, 가스발생기 및 연소기 등의 엔진 주요 구성품의 개발시험에 적용된 상태진단 및 비상보호시스템에 대한 적용 사례에 대해서도 살펴보았다.

  • PDF

Optimization of In-vivo Monitoring Program for Radiation Emergency Response

  • Ha, Wi-Ho;Kim, Jong Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.333-338
    • /
    • 2016
  • Background: In case of radiation emergencies, internal exposure monitoring for the members of public will be required to confirm internal contamination of each individual. In-vivo monitoring technique using portable gamma spectrometer can be easily applied for internal exposure monitoring in the vicinity of the on-site area. Materials and Methods: In this study, minimum detectable doses (MDDs) for $^{134}Cs$, $^{137}Cs$, and $^{131}I$ were calculated adjusting minimum detectable activities (MDAs) from 50 to 1,000 Bq to find out the optimal in-vivo counting condition. DCAL software was used to derive retention fraction of Cs and I isotopes in the whole body and thyroid, respectively. A minimum detect-able level was determined to set committed effective dose of 0.1 mSv for emergency response. Results and Discussion: We found that MDDs at each MDA increased along with the elapsed time. 1,000 Bq for $^{134}Cs$ and $^{137}Cs$, and 100 Bq for $^{131}I$ were suggested as optimal MDAs to provide in-vivo monitoring service in case of radiation emergencies. Conclusion: In-vivo monitoring program for emergency response should be designed to achieve the optimal MDA suggested from the present work. We expect that a reduction of counting time compared with routine monitoring program can achieve the high throughput system in case of radiation emergencies.

지능형 클러스터 감시망 비상등관리시스템 개발 (The Implementation of Emergency Light Monitoring System by Intelligent Cluster Surveillance Network)

  • 최재명;강희조
    • 한국항행학회논문지
    • /
    • 제15권5호
    • /
    • pp.906-912
    • /
    • 2011
  • 본 논문에서는 건물에 산재되어 있는 비상등을 효과적으로 관리하기 위하여 별도의 통신선을 포설하지 않고 지능형 클러스터 감시망을 구성한다. 또한, 비상등의 위치에 구애받음 없이 감시장치를 설치할 수 있고, 감시망을 구성함에 있어 게이트웨이로 지정된 감시장치가 고장나더라도 사각지대 없이 비상등의 상태를 감시 및 관리가 가능하며, 비상등을 항시 점검 및 관리할 수 있는 비상등감시장치와 비상등관리시스템을 구현하였다. 실험결과, 구현 시스템은 설계 규격대로 동작하였고, 감시망 구성, 상태정보 측정 및 초기화가 안정적으로 구성됨을 확인하였다.

TRS에 의한 생체신호의 전도에 대한 연구 (A Study on the Transmission of Bio-Signal by TRS)

  • 곽준혁;최조천
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 춘계종합학술대회
    • /
    • pp.366-372
    • /
    • 2002
  • Tele-medicine and emergency medical system are necessary for moving from an accidental point or far distance to a hospital and emergency treatment or home treatment before a hospital. Emergency treatment is extremely important in the case of death before arriving a hospital and deformed or disabled by medical treatment delay. A necessary element for this medical system is the emergency communication system. This system is on preparing for an ability of furnishing patient status to a corresponding health service by monitoring the patient at an ambulance of the accident place. This is the transportation of basic biological information of a patient to a medical center by wireless communication system and the corresponding hospital or medical center examine the patient by monitoring, then they can send emergency medical order to the patient for emergency treatment. The TRS is most efficient way of emergency medical communication system, which is currently used with popularity. In this paper studied simultaneously a way of detecting and transporting bio-logical signals, and monitoring of transporting data with communication of voice in the accident place or ambulance.

  • PDF

Emergency Monitoring System Based on a Newly-Developed Fall Detection Algorithm

  • Yi, Yun Jae;Yu, Yun Seop
    • Journal of information and communication convergence engineering
    • /
    • 제11권3호
    • /
    • pp.199-206
    • /
    • 2013
  • An emergency monitoring system for the elderly, which uses acceleration data measured with an accelerometer, angular velocity data measured with a gyroscope, and heart rate measured with an electrocardiogram, is proposed. The proposed fall detection algorithm uses multiple parameter combinations in which all parameters, calculated using tri-axial accelerations and bi-axial angular velocities, are above a certain threshold within a time period. Further, we propose an emergency detection algorithm that monitors the movements of the fallen elderly person, after a fall is detected. The results show that the proposed algorithms can distinguish various types of falls from activities of daily living with 100% sensitivity and 98.75% specificity. In addition, when falls are detected, the emergency detection rate is 100%. This suggests that the presented fall and emergency detection method provides an effective automatic fall detection and emergency alarm system. The proposed algorithms are simple enough to be implemented into an embedded system such as 8051-based microcontroller with 128 kbyte ROM.

Research on the development law of karst fissures and groundwater characteristic in Xintian County

  • Xin, Zhou;Tengfei, Yao;Can, Wang;Jian, Ou;Pengfei, Zheng;Kaihong, Chen;Xiting, Long
    • Membrane and Water Treatment
    • /
    • 제13권6호
    • /
    • pp.303-312
    • /
    • 2022
  • The natural hydrology and geological conditions of Xintian County was investigated, the development law of regional karst fissures was studied, the groundwater was collected and tested through a large-scale collection of groundwater to obtain the change law of chemical characteristics and water quality characteristics of groundwater, and the water quality evaluation was carried out for the regional karst groundwater in this paper. The results show that, the whole area is dominated by carbonate rock distribution areas, and the distribution of water systems is relatively developed. The strata are distributed from the Lower Paleozoic Cambrian to the Cenozoic Quaternary, and contain multiple first-order folds. The regional karst dynamic action is strong, and many tunnels or caves of different scales were shown, which are conducive to the enrichment of groundwater. Karst groundwater is neutral and alkaline water, the water is clear and transparent with good taste, and meets the national drinking water hygiene standards. The content of toxic trace elements and fluoride in the water source is generally lower than the limit value specified by the national standard and the accumulated toxic heavy metals is never found. The overall water quality is of good quality and suitable for the development and utilization of various purposes.

Remote Monitoring of Patients and Emergency Notification System for U-Healthcare

  • Lee, Jun;Jang, Hyun-Se;Yang, Tae-Kyu;Seo, Yong-Ho
    • International journal of advanced smart convergence
    • /
    • 제2권1호
    • /
    • pp.1-5
    • /
    • 2013
  • This study proposes a remote monitoring of patients and emergency notification system with a camera and pulse wave sensor for U-Healthcare. The proposed system is a server client model based U-Healthcare system which consists of wireless clients that have micro-controller, embedded-board for patient status monitoring and a remote management server. The remote management server observes the change of pulse wave data individually in real-time sent from the clients that is to be remote-monitored based on the pulse wave data stored by users and divides them into caution section and emergency section. When the pulse wave data of a user enters an emergency situation, the administrator can make a decision based on the real-time image information and pulse rate variability. When the status of the monitored patient enters the emergency section, the proposed U-healthcare system notifies the administrator and relevant institutions. An experiment was conducted to demonstrate the pulse wave recognition of the proposed system.