• Title/Summary/Keyword: Emergency generator

Search Result 200, Processing Time 0.034 seconds

Seoul World Cup Stadium Electric Plan (서울월드컵경기장 전기설계)

  • 최용민
    • Journal of the Korean Professional Engineers Association
    • /
    • v.34 no.5
    • /
    • pp.40-43
    • /
    • 2001
  • In order for the World cup football game to be operated stably with duplicate service electric power supply, It is done, emergency generator and the U.P.S it establishes. the electric power system power control, lighting control, integrated monitoring. rue fighting. obstruction light, the searchlight, snow melting, electric erosion shield. grounding, the lightening protection and viewable lighting, stadium floodlight and an electric bulletin board it composed of the back which it sells.

  • PDF

A Study on the Reliability Evaluation of Start-up Power Supply in Fossil Power Plant by Minimal Cut-Set Method (최소 컷셋법에 의한 화력발전소 기동전원의 신뢰도 예측에 관한 연구)

  • Choe, Gyu-Sik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.358-364
    • /
    • 1999
  • The auxiliary transformers or start-up/stand-by transformer(s) are installed against the start-up and shut-down of generator and emergency status in fossil power plant. The on-site power supply configuration using these transformers must be determined, considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and ecfonomy of plant. The auxiliary or start-up/stand-by power supply configuration has been determined considering only safety requirements and construction cost until now in Korea. This paper presents general theorems for the reliability estimation and proposes 2-unit based 4 alternatives for the start-up power supply stystem of 500㎿ standardized fossil power plant. The reliability and unavailability of equipment, system and configuration are determined using minimal cut-set methodology. The optimized plan of 4 alternatives is determined based on this ultimate reliability and unavailability.

  • PDF

A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod (FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구)

  • Che, Gyu-Shik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

Development of Reliability Management System of Emergency Diesel Generator for Nuclear power plants (원전 비상디젤발전기 신뢰도 관리시스템 개발)

  • Ju, Song-Jae;Lee, Jeong-Il;Sin, Jin-Ho;Kang, Joo-Yeong;Yi, Bong-Jae
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.115-117
    • /
    • 2005
  • 본 논문은 원자력발전소 비상디젤발전기의 신뢰도 및 성능변화 추이를 감시하고, 이에 필요한 데이터를 관리하는 비상디젤발전기 신뢰도 프로그램 개발에 관하여 기술하였다. 이 프로그램은 인트라넷 기술을 이용하여 신뢰도 감시, 성능 감시, 그리고 관련정보로 크게 3가지 모듈로 구분하여 개발하였다. 현재 이를 통하여 원전 비상디젤발전기의 운전 및 정기점검 데이터를 입력 관리할 수 있도록 서비스를 개시하였으며, 이미 기존에 입력된 데이터를 이용하여 신뢰도 및 이용 불능도를 계산할 수 있고 또한 성능변화 추이를 감시할 수 있다.

  • PDF

Evaluation of Probability of Failure on Demand (PFD) for Emergency Diesel Generator Excitation Control System (디젤발전기 여자시스템의 고장확률 분석에 관한 연구)

  • Lee, Joo-Hyun;Lim, Ick-Hun;Rhew, Ho-Sun;Huh, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1934-1935
    • /
    • 2007
  • 본 논문은 원자력발전소 안전계통인 비상전원 공급용 디젤발전기의 여자시스템에 대해서 신뢰성 불럭선도를 이용하여 시스템을 모델링하고, 신뢰성 분석을 수행하고 그 결과 기동요구시 실패확률을 산출하는 방법과 결과를 기술하였다. 비상디젤발 전기 여자시스템을 구성하는 모든 부품의 고장률을 Telcordia SR-332 기준서의 부품수 방법을 이용하여 분석하고 FMEA (Failure Mode Effect Analysis)를 수행하며 IEC 61508에서 제시하고 있는 기동요구 시 실패확률(Probability of Failure on Demand, PFD)을 산출하였다.

  • PDF

An Intelligent Surveillance System for Urban Transit (도시철도 지능형 종합감시 시스템 적용방안 연구)

  • Ahn, Tae-Ki;Lee, Woo-Dong;Chung, Jong-Duk;Kim, Mun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1187-1188
    • /
    • 2007
  • Most of the surveillance systems are based on CCTV, closed circuit Television. A surveillance system for urban transit is also based on CCTV. Urban transit operation corporations have a CCTV system and a lot of cameras to monitor the situation for the passengers, and the important facilities. But this system has some problems that it cannot respond to a state of emergency immediately. In this paper, we describe a configuration of an intelligent surveillance system for urban transit to solve that problems. Our proposed configuration include a camera with some intelligent module, and a processor to integrate various data from not only cameras, but also sensors such as a temperature sensor, a heat sensor, sound sensor and etc. and some other data generator. This system configuration can decide the state of the passengers and the facilities. The surveillance system with this configuration can available with the existing surveillance system without a considerable improvement.

  • PDF

Measurement of safety rods reactivity worth by advanced source jerk method in HWZPR

  • Nasrazadani, Z.;Ahmadi, A.;Khorsandi, J.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.963-967
    • /
    • 2019
  • Accurate measurement of the reactivity worth of safety rods is very important for the safe reactor operation, in normal and emergency conditions. In this paper, the reactivity worth of safety rods in Heavy Water Zero Power Reactor (HWZPR) in the new lattice pitch is measured by advanced source jerk method. The average of the results related to two different detectors is equal to 29.88 mk. In order to verify the result, this parameter was compared to the previously measured value by subcritical to critical approach. Different experiment results are finally compared with corresponding calculated result. Difference between the average experimental and calculated results is equal to 2.2%.

A Study on the ESS Construction and Proper Operation Considering the Load Characteristics of the Distribution Logistics Facilities (유통물류시설 부하특성을 고려한 ESS 구축 및 적정 운영 방안에 관한 연구)

  • Heo, Donghyeok;Choi, Okhwan;Kwon, Dongmyeong
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.36-46
    • /
    • 2019
  • Through the application of ESS-based fusion products to the demonstration site of the urban distribution logistics facilities for designing the peak control and the substitution before the emergency generator operation by product application and the effective application method by the product application and the data analysis by overcoming the spatial limitation of ESS installation and distribution, And the expansion of distribution and logistics facilities.

Dynamic reliability analysis framework using fault tree and dynamic Bayesian network: A case study of NPP

  • Mamdikar, Mohan Rao;Kumar, Vinay;Singh, Pooja
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1213-1220
    • /
    • 2022
  • The Emergency Diesel Generator (EDG) is a critical and essential part of the Nuclear Power Plant (NPP). Due to past catastrophic disasters, critical systems of NPP like EDG are designed to meet high dependability requirements. Therefore, we propose a framework for the dynamic reliability assessment using the Fault Tree and the Dynamic Bayesian Network. In this framework, the information of the component's failure probability is updated based on observed data. The framework is powerful to perform qualitative as well as quantitative analysis of the system. The validity of the framework is done by applying it on several NPP systems.