• 제목/요약/키워드: Emergency controller

검색결과 94건 처리시간 0.024초

적응 제어 방식을 이용한 혈압자동 조절기에 관한 연구 (A Study on the Automatic Pressure Controller Using Adaptive Control Algorithma)

  • 이상훈;김영철;민병구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.648-651
    • /
    • 1986
  • Sometimes, there are conditions when rapid control of the hypertension needed such as malignant hypertension, and the preoperative pereparation of the hypertensive patient requiring emergency operation, etc. Using the adaptive control algorithm, the mean arterial pressure reduction is achived rapidly and safely in hypertensive rabbit. Among the adaptive control algorithms the pole assignment self tuning control algorithm is superial to the one step ahead minium variance control algorithm. The convergence time is less than 600 sec, and the standard deviation of experimental data are less than 4 mmHg.

  • PDF

양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구 (A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication)

  • 이봉섭;곽동걸;정도영;천동진
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

비정상상황에 대한 항공교통관제사의 개인 및 팀 차원의 대응이 조직효과성에 미치는 영향 연구 : 인지전략 구성요인을 중심으로 (A Study for the Effect of Air Traffic Controller's Individual and Team Response against Emergency Situation on Organizational Effectiveness)

  • 전종덕;이남령;이진숙;박성식
    • 한국항공운항학회지
    • /
    • 제26권1호
    • /
    • pp.10-24
    • /
    • 2018
  • This paper tried to analyze the response of air traffic controller(ATC) against abnormal situations using survey based on cognitive strategies suggested by Malakis et al.(2010). The survey designed to empirically analyze the effect of the cognitive strategy factors on organizational effectiveness. The main purpose of this research was as follows: First, it was analyzed both the individual-scale and team-scale factors which constructed the cognitive strategy against abnormal situations. Secondly, how seriously impact the ATC's cognitive strategies on their organizational effectiveness. The organizational effectiveness was divided into such two latent variables as job absorption and job satisfaction. According to the a analysis, it was proven that premeditated act of ATC had a positive significant effect on team-scale cognitive strategies such as teamwork, communication and error management. Moreover, it was found out the team-scale cognitive strategies had also a positive significant effect on job absorption. On the other hands, individual-scale cognitive strategies had no or negative effect on job absorption. Job absorption was proven to have a significant effect on job satisfaction of ATC.

전압제어 링 발진기를 이용한 LED구동회로 및 조명제어기설계 (Design of LED Driving Circuit using Voltage Controlled Ring Oscillator and Lighting Controller)

  • 권기수;서영석
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.1-9
    • /
    • 2010
  • LED구동회로및 제어회로를 개발하였다. 개발된 LED구동회로는 새로운 PWM회로를 가지고 있으며 LED열의 디밍, 전류 및 온도제어 및 통신 기능을 할 수 있다. 개발된 PWM회로는 기본적인 디지털 논리소자를 사용하여 만들어 질 수 있는 두 개의 링 발진기와 한 개의 카운터로 구성되어 있다. 부가적으로 이 회로는 온-오프 제어 모드, 비상모드, 전력절감모드를 가지고 있으며 직열통신을 이용해서 제어된다. 설계 된 PWM 발생기와 제어회로는 마그나칩/하이닉스의 디지털 공정을 이용하여 제작되었다. 제작된 칩은 LED구동장치와 제어기 보드에 장착되어 테스트 되었으며 성공적으로 동작하였다.

피드포워드 제어기를 사용한 동기발전기의 과도특성 개선 (Improvement of Transient Performance of Synchronous Generator using Feedforward Controller)

  • 안영주
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.

비정상 항공기가 항공교통관제사에게 미치는 영향에 대한 연구 (상황인식과 업무부하를 중심으로) (A Study on the Operational Impact of Abnormal Aircraft in ATC Operations (Focusing on Situation Awareness and Workload))

  • 전정대;이영혁;최연철
    • 한국항공운항학회지
    • /
    • 제17권3호
    • /
    • pp.32-39
    • /
    • 2009
  • Due to the lack of navigable airspace caused by worldwide air traffic increases, air traffic control(ATC) services are becoming more complex, which results in the increase of aircraft accidents. To cope with these challenges, major aviation institutes abroad are actively conducting research regarding the human factors affecting controllers but as of late, no such specialized activities have been found in Korea. Due to the dynamic attributes of ATC operations, management of controller's situation awareness(SA) and workload, and knowledge on the impact of abnormal aircraft to controllers are very important. Furthermore, using actual flight data of each country will lead to valuable results, because individually, it has different airspace characteristics and air traffic volumes. This study assumed that air traffic difficulties would affect the controller's SA and workload. To testify the above hypothesis, the abnormal air traffic situations are simulated by using ATC simulator. The findings indicated that the effect of traffic situations containing abnormal aircraft on the controller's SA and workload, it led to demand increase and supply decrease in SA, and increased mental demand, temporal demand, effort and mean workload score in the workload.

  • PDF

전력선 통신 기반 전관 방송시스템의 펌웨어와 UI (Firmware and UI for Power Line Communication Based Public Address System)

  • 김석;김대익
    • 한국전자통신학회논문지
    • /
    • 제14권1호
    • /
    • pp.127-136
    • /
    • 2019
  • 전관방송 시스템은 위급상황 및 비상상황에서도 누구나 손쉬운 조작과 운영, 그리고 장비의 안정적 동작이 우선시되어야 한다. 본 논문에서는 전력선 통신 기반 전관방송 시스템 사용자에게 편리성과 효율성을 제공하기 위해, 전관방송 시스템의 PLC(Power Line Communication) 제어기와 UI(User Interface) 그리고 PLC 제어기와 PLC 스피커 간의 통신을 제어하기 위한 펌웨어를 구현하였고, 사용자가 컴퓨터 화면에서 손쉽게 사용할 수 있도록 UI 소프트웨어를 개발하였다.

소방 비상용 태양전지 발전시스템의 고효율 직류-교류 인버터 설계에 관한 연구 (A Study on High Efficiency DC-AC Inverter of Solar Cell Power System Used in Fire Emergency Equipment)

  • 곽동걸;이봉섭
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.181-187
    • /
    • 2006
  • 본 논문에서는 소방 비상용으로 이용되는 태양전지 발전시스템을 제안하고, 발전시스템의 효율을 증대시키기 위한 새로운 고효율의 전력변환장치(승압용 초퍼와 인버터)가 설계된다. 직류-직류(DC-DC) 승압용 초퍼와 직류-교류(DC-AC) 인버터는 사용된 제어스위치들의 스위칭 손실을 최소화하기 위해 공진회로를 이용한 새로운 소프트 스위칭 기법이 적용되고 시스템의 효율을 증대시킨다. 또한 본 논문에서는 태양전지(solar cell)의 최대전력 전송에 의한 태양전지의 효율적인 사용을 위한 태양전지 발전전력의 최대점 $P_{max}$을 손쉽게 추종하고 검출하는 새로운 제어기법과 제어회로에 대해 상세히 해석된다. 고효율의 전력변환 장치와 태양전지 최대전력 전송회로는 컴퓨터 시뮬레이션과 실험을 통하여 그 타당성이 입증된다.

공항 지상 근무자의 심폐소생술 수행능력 (Performance Ability after CPR Education of the ground workers in an airport)

  • 신지훈
    • 한국응급구조학회지
    • /
    • 제13권3호
    • /
    • pp.29-40
    • /
    • 2009
  • Objective : This study is an experimental study which is designed to examine the differences between knowledge and self-confidence before and after theory education(CPR PPT material) based on guidelines of CPR and emergency cardiac treatment of American Heart Association(AHA, 2005) and video self-instruction program for the general public by Korean Association of Cardiopulmonary Resuscitation(KACPR), trace CPR performance ability after CPR and AED education and investigate the accuracy of artificial respiration and chest compression, and know the difference in CPR performance abilities including AED. Methods : Subjects of this study include ground crews and staffs at M airport in G province equipped with emergency equipments for CPR according to Art. 47, Sec. 2 of Emergency Medical Law, airport police, rent-a-cops, security guard, quarantine officer, custom officer, and communication, electricity, civil engineering, facility management staff, airport fire fighting staff, air mechanic, traffic controller, and airport management team among airport facility management staffs. They were given explanation of necessity of research and 147 of 220 subjects who gave consent to this research but 73 who were absent from survey were excluded were used as subjects of this study. of 147 subjects, there were 102 men and 45 women. Results : 1) Knowledge score of CPR was $6.18{\pm}0.87$ before instruction and it was increased to $15.12{\pm}1.78$ after instruction, and there was statistically significant difference. 2) Self-confidence score in CPR was $3.16{\pm}0.96$ before instruction and it was increased to $7.05{\pm}0.75$ after instruction, and there was statistically significant difference. 3) Total average score in CPR performance ability after instruction was 7.46 out of 9, performance ability was highest in confirmation of response as 144(97.95%), follwed by request of help as 140(95.25%) and confirmation of respiration as 135(91.83%), and lowest in performing artificial respiration twice(gross elevation of chest) as 97(65.98%). Accuracy of artificial respiration(%) was $28.60{\pm}16.88$ and that of chest compression(%) was $73.10{\pm}22.16$. 4) Performance ability of AED after instruction showed proper performance in power on by 141(95.91%) and attaching pad by 135(91.83%), hand-off for analyzing rhythm showed 'accuracy' in 115(78.23%) and 'non-performance' in 32(21.77%), delivery of shock and hand-off confirmation showed 'accuracy' in 109(74.14%) and 'inaccuracy' in 38(25.86%), and beginning chest compression immediately after AED was done by 105(71.42%).

  • PDF

AVR의 응답속도개선을 위한 제어기법에 관한 연구 (Control techniques for improving response of the AVR)

  • 이형기;김송현;김현수;김기량;김관형
    • 한국정보통신학회논문지
    • /
    • 제19권11호
    • /
    • pp.2534-2539
    • /
    • 2015
  • 발전기의 전압조정장치(AVR)를 이용하여 전압을 조절하는 방식은 기존 아날로그방식과 교체중인 디지털방식을 나눌 수 있다. 일반적으로 브러쉬레스형의 여자시스템을 이용하여 전압을 조절할 경우 전부하에 대하여 전압변동을 작게 하여야 한다. AVR의 제어방법으로 PID(비례-적분-미분)제어방식이 많이 사용되고 있다. 그러나 이 제어기법은 제어대상에 대하여 제어기의 파라미터를 조절하여 과도응답을 줄이고 있다. 따라서 제어대상이 달라질 경우 다시 제어기의 파라미터를 다시 설정해야하는 문제점이 있다. 본 연구에서는 제어대상의 파라미터 변동에 대하여 제어기의 파라미터를 재설정 필요없이 iPID(intelligent PID)제어기를 이용하여 발전기 AVR시스템에 적용하여 전부하 시에도 전압변동이 작은 응답을 얻도록 설계하고 시뮬레이션과 실험을 통하여 과도응답을 개선하였다.