• Title/Summary/Keyword: Emergency Water

Search Result 440, Processing Time 0.03 seconds

Vulnerability AssessmentunderClimateChange and National Water Management Strategy

  • Koontanakulvong, Sucharit;Suthinon, Pongsak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.204-204
    • /
    • 2016
  • Thailand had set the National Water Management Strategy which covered main six areas in the next 12 years, i.e., by priority: (1) water for household, (2) water for agricultural and industrial production, (3) water for flood and drought management, (4) water for quality issue, (5) water from forest conservation and soil erosion protection, (6) water resources management. However due to the climate change impact, there is a question for all strategies is whether to complete this mission under future climate change. If the impact affects our target, we have to clarify how to mitigate or to adapt with it. Vulnerability assessment was conducted under the framework of ADB's (with the parameters of exposure, sensitivity and adaptive capacity) and the assessments were classified into groups due to their different characteristic and the framework of the National Water Management Strategy, i.e., water supply (rural and urban), water for development (agriculture and others), water disasters (floods (flash, overflow), drought, water quality). The assessments identified the parameters concerned and weight factors used for each groups via expert group discussions and by using GIS mapping technology, the vulnerability maps were produced. The maps were verified with present water situation data (floods, drought, water quality). From the analysis result of this water resources management strategy, we found that 30% of all projects face the big impacts, 40% with low impact, and 30% for no impact. It is clear that water-related agencies have to carefully take care approximately 70% of future projects to meet water resources management strategy. It is recommended that additional issues should be addressed to mitigate the impact from climate risk on water resource management of the country, i.e., water resources management under new risk based on development scenarios, relationship with area-based problems, priority definition by viewpoints of risk, vulnerability (impact and occurrence probability in past and future), water management system in emergency case and water reserve system, use of information, knowledge and technology in management, network cooperation and exchange of experiences, knowledge, technique for sustainable development with mitigation and adaptation, education and communication systems in risk, new impact, and emergency-reserve system. These issues will be described and discussed.

  • PDF

The Utility of Non-Invasive Nasal Positive Pressure Ventilation for Acute Respiratory Distress Syndrome in Near Drowning Patients

  • Kim, June Hyeong;Sun, Kyung Hoon;Park, Yong Jin
    • Journal of Trauma and Injury
    • /
    • v.32 no.3
    • /
    • pp.136-142
    • /
    • 2019
  • Purpose: Near drowning refers to immediate survival after asphyxia due to submersion or immersion in water, which is a crucial public safety problem worldwide. Acute lung injury or acute respiratory distress syndrome (ARDS) is a common complication of near drowning. The purpose of this study was to investigate the feasibility and effectiveness of noninvasive nasal positive pressure ventilation (NINPPV). Methods: This retrospective study was conducted at a tertiary emergency department. NINPPV was administered for moderate ARDS caused by submersion or immersion in patients who were older than 18 years, from January 2015 to December 2018. We collected the demographic (age, sex, length of hospital stay, and outcome), laboratory (arterial blood gas, lactate, oxygen saturation, partial pressure of oxygen divided by the fraction of inspired oxygen, complete blood count, blood urea nitrogen, and creatinine), and clinical data (acute lung injury index and ventilator failure) of the patients. A statistical analysis was performed using Statistical Package for the Social Sciences version 20.0 for Windows. Results: NINPPV treatment was provided to 57 patients for near drowning, 45 of whom (78.9%) were successfully treated without complications; in 12 (21.1%), treatment was changed to invasive mechanical ventilation within 48 hours due to ARDS or acute kidney injury. NINPPV treatment was successful in 31 (75.6%) out of 41 sea-water near drowning patients. They were more difficult to treat with NINPPV compared with the fresh-water near drowning patients (p<0.05). Conclusions: NINPPV would be useful and feasible as the initial treatment of moderate ARDS caused by near drowning.

Comprehensive Security and Crisis & Emergency Management for Protecting Critical Infrastructure

  • Lee, Jae-Enn
    • International Journal of Contents
    • /
    • v.5 no.3
    • /
    • pp.71-78
    • /
    • 2009
  • Recently, interest has heightened over 'critical infrastructures' and their reliability in the face of potential terrorist attack. Assault on any of the critical infrastructures as transportation, power, water, telecommunications, and financial services, entails great consequences for their users as well as the other interdependent critical infrastructures. How to protect our vital critical infrastructures is the key question in this paper. The purpose of this article is to suggest the implications for crisis and emergency management to protect the critical infrastructures in our society. For achieving the purpose, we examined the concept of comprehensive security, national crisis, and critical infrastructure and, using the holistic approach, we examined the comprehensive emergency management for suggesting the implications for establishing the critical infrastructure protection system; building up the high reliability organization, organizing and partnering, assessing the risk, preparing first responders, working with private owners of critical infrastructures, working with communities, improving the administrative capacity.

Determination of the Optimal Location for Water Treatment Plants in the Decentralized Water Supply System (분산형 용수공급시스템 구축을 위한 정수처리시설 최적 위치 결정)

  • Chang, Dong-Eil;Ha, Keum-Ryul;Jun, Hwan-Don;Kim, Jeong-Hyun;Kang, Ki-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Major issues in water supply service have changed from expansion of service area to improvement of service quality, i.e., water quality and safety, and early response to emergency situation. This change in the service concept triggers the perceptions of limitation with the current centralized water supply system and of necessities of decentralized (distributed) water supply system (DWSS), which can make up the limitations. DWSS can reduce the possibility of water supply outage by establishing multiple barriers such as emergency water supply system, and secure better water quality by locating treatment facilities neighboring consumers. On the other hand, fluctuation of water demand will be increased due to the reduced supply area, which makes difficult to promptly respond the fluctuating demand. In order to supplement this, hybrid water supply system was proposed, which combined DWSS with conventional water supply system using distributing reservoir to secure the stability of water supply. The Optimal connection point of DWSS to existing water supply network in urban area was determined by simulating a supply network using EPANET. Optimal location of decentralized water treatment plant (or connection point) is a nodal point where changes in pressure at other nodal points can be minimized. At the same time, the optimal point should be selected to minimize hydraulic retention time in supply network (water age) to secure proper water quality. In order to locate the point where these two criteria are satisfied optimally, Distance measure method, one of multi-criteria decision making was employed to integrate the two results having different dimensions. This methodology can be used as an efficient decision-support criterion for the location of treatment plant in decentralized water supply system.

Causes of Burn and Emergency Care on the Spot for the Patients Admitted to Three Hospitals in Taegu (대구시내 종합병원에 입원한 화상환자의 화상원인과 현장에서 취한 응급처치)

  • Chu, Min;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.238-244
    • /
    • 1988
  • This study was conducted to investigate the causes of burn and emergency cares taken on the spot for the burn patient. Study population included 161 burn patients admitted to 2 university hospitals and 1 general hospital in Taegu from November 1, 1987 to April 30, 1988. Patients or guardians were interviewed with a structured questionnare. Out of 161 burn patients 111(68.9%)were males and 50(31.1%) females. Preschool children of 1-4 years old accounted for 29.8% of the total patients. Burns of children under 15 years of age took place at home in 91.0%, while 48.3% of burns of adult (15 years and over)males occurred at the working place, and 68.0% of adult females occurred at the home. Out of total burns occurred at home 39.8% took place at kitchen/dining room and 24.1% in the room. The most common cause of burns in children was the boiling water or hot food (74.3%). In adults the common causes were electrical burn(22.4%), hot water or food(19.0%) and explosion(12.1%) for males, and hot water or food(32.0%) and explosion (20.0%) for females. Common emergency cares for the burn taken on the spot were undressing(64.6%), pouring Soju(liquor)(13.7%), and pouring cold water(5.0%). There were a few cases who applied ash, soy or salt. To prevent burn, it is recommended to remodel the traditional kitchen and coal-briquet hole, to strengthen the safety control of LP Gas and LN Gas supply, to educate the public for the handling method for such gases, to strengthen the occupational safety control, to improve the safety device for the electric wire and socket, and to limit the temperature of hot water at home and public baths.

  • PDF

Cost analysis of water supply and development of desalination vessel as a drought response (가뭄 시 광역자치단체 별 물 비용 분석 및 해상 이동형 담수화 플랜트 이용 대응 방안 연구)

  • Yang, Hayeon;Koo, Jaewuk;Hwang, Taemun;Jeong, Seongpil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • Due to global climate change, Korea is experiencing flooding and drought severely. It is hard to manage water resources because intensive precipitation during short periods and drought are commonly occurred in Korea, recently. Severe drought occurred in 2015 and 2017 in the islands, and coastal and inland areas in Korea, and the citizens experienced decreased water supply and emergency water service by using bottled water. Therefore, the Korean government provided additional governmental funds such as the grant of drought disaster. In this study, we tried to calculate the cost of water for drought response based on the cost of tap water for the regional local governments in Korea and the grant of drought disaster by the Ministry of the Interior and Safety in Korea, etc. The estimated costs of water for drought responses in coastal and inland areas which have a chance to apply alternative water sources such as brackish or seawater desalination and water reuse in Korea were higher than in other areas in Korea. Additionally, as the novel approach of drought response, the 300 ㎥/day-scale desalination vessel was suggested to provide desalinated water for the islands in Korea. The estimated expenses of water supply for the target island areas (Sinan-gun and Jindo-gun) by the desalination vessel was lower than those by emergency water service by using bottled water.

Radiation Protection Effects of Schizonepeta Tenuifolia Water Extracts by Gender in SD Rats (SD rats의 성별에 따른 형개 열수추출물의 방사선 방호효과)

  • Lee, Ji-Eun;Kim, Jang-Oh;Lee, Yoon-Ji;Jeon, Chan-hee;Heo, Sung-Hoe;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.313-320
    • /
    • 2021
  • This study evaluates the radiation protection effects of Schizonepeta tenuifolia water extract on white rat by gender. Schizonepeta tenuifolia contains polyphenol and flavonoid, which are typical substances that remove free radical. Thus, to determine the effectiveness of radiation protection, the Schizonepeta tenuifolia water extract was administered to Sparaqu-Dawely (SD) rat males and females for two weeks, followed by hematological analysis, analysis of changes in the length of the small intestine villi length, and SOD activity evaluation. The male rat in ST+IR group showed a slightly greater recovery of platelets than the IR group. The ST+IR group also showed a higher platelet recovery capability than the IR group. lymphocyte showed that male and female rat ST+IR groups have higher resilience than IR groups likewise platelet. After irradiation, the villi length of the male rat and female rat decreased less in ST+IR group than in the IR group, indicating that the villi length of all genders was less damaged. This result confirmed that the Schizonepeta tenuifolia water extract had a radiation protection effect.

Design of a Control System for the Emergency Diesel Generator (비상용 디젤발전기 제어시스템 설계)

  • Kim, Jin-ae;Joo, Jae-hun;Baek, Pan-Geun;Kim, Byeong-Jun;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.849-853
    • /
    • 2009
  • A generator is in use for a moving vehicle like car, aircraft, ship as well as key industry including a thermal power plant, a water power plant, a nuclear power plant, and so on. Such the AC generator plays an important role in vehicle, ship, aircraft, and so forth, at the point of generating electric power. Especially in the matter of the ship, the emergency generator system is mounted to provide against malfunction of main generator on a voyage. So, it is ordered that the system can monitor the main generator and operate the emergency generator when the emergency happens. This study is about controller for the emergency diesel engine generator and design of a various software.

  • PDF