• Title/Summary/Keyword: Emergency System

Search Result 2,760, Processing Time 0.032 seconds

A Study of Trends in Continuing Education Published in the Korean Nurse (간호협회지를 통해 본 보수교육의 역사적 경향 1962년 ~ 1995년)

  • Shin, Sung-Rae;Kim, Kyung-Sun;Lee, Sook
    • The Korean Nurse
    • /
    • v.35 no.2
    • /
    • pp.52-70
    • /
    • 1996
  • This historical research was conducted to analyze and categorize the titles which were presented in the journal, The Korean Nurse, from August 1962 to October 1995. Titles which were published with the purpose of educating graduate nurses and to update 0 their nursing knowledge to improve professional practice were included. There were 348 articles published from the beginning of publication in August, 1962 to October, 1995. All of the journals were reviewed except nine missing journals which were not available in any library. According to the characteristics of the articles in the periodical, the articles were divided into three periods. In each of the three peroids there were five categories: Subject, Clinical Practice, Fundamentals of Nursing Science, Nursing Administration, Others. These categories were adopted from Kim's(1994) division system which was developed to analyze nurse's insurance education program. The special feature peroid was from August, 1962 to December, 1974. In this period the articles were presented in an unorganized manner in the area of special feature or main issue. The largest area was the subject category(44%). The second largest area wes the fundamental of nursing science category(31%). From May, 1975 to December, 1977, the articles with the educational purposes were published in a designated area called continuing education. This period was labelled as the continuing education period. Among the published articles in this period, 45% focused on the subject category and 45% on the fundamentals of nursing science category. In this period the articles were focusing on nurses 'work in specific areas such as industry, nurses' aid schools, and nursing administration, articles on physical assessment first started to appear. The written continuing education period was from January 1978 to October, 1995. All the educational articles published in this area were analyzed and categorized into five areas as for the other periods. 48% of the articles focused on the subject category. In the mid-eighties, the term nurse specialist first.appeared and ten years later in 1990, the titles were subdivided into more specific titles, such as, home nursing, industrial nursing, emergency nursing, 23% were in the fundamental nursing science category and they dealt with nursing process, nursing theories, theory development. For the content analysis, three articles, one from each period, dealing with cardiovscular diseases were selected for comparsion. First, the special feature period, the title of the article was on diet therapy for cardiovascular disease patients, but instead the content was about rest, hygiene, medication, observation. They recommended rings to prevent bed sores, which is now considered as a cause for bed sores. In the continuing education period, the content was more focused on rehabilitation rather than general nursing .care. It became more specific, systematic, and organized compared with the special feature period. In the written continuing education period, the focus was on rehabilitation, not broadly, but very specifically on exercise. The further research on the content analysis is recommended along with a comparison of the trends in the Journal of Nurses Academic Society.

  • PDF

The Research of Process High Alarm Priority Analysis for Efficient Emergency Response (효율적인 비상대응을 위한 Process High Alarm의 Priority 분석)

  • Kim, Youngse;Cho, Gyusun;Jun, Jinwoo;Kim, Byungjick;Lee, Joonwon;Park, Kyoshik
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.604-609
    • /
    • 2020
  • The purpose of this study is to check the priority control status of the current operation process alarm by comparing the priority of the alarm set up in PV high trip point, which is being installed and operated in the domestic petrochemical industry, with the criteria presented in ISA 18.2 International Standard or EEMUA 191 Guidelines. In the event of a process problem, excessively set high alarm is provided to the driver in a short period of time, making it difficult to identify the alarm that needs to be handled first. As a result, it is likely that the operator will not be able to carry out appropriate actions within the specified time frame, and many cases have been reported leading to unexpected process shutdowns or process accidents. Therefore, this study aims to introduce international standards related to alarm management and identify the level of alarm control used at the domestic petrochemical industry site to inform potential risks that may occur in the petrochemical process of the national industrial complex in the future and suggest ways to reduce risk factors. This paper was submitted to Professor Lee Inbeom's retirement anniversary issue.

A Preliminary Study of the Global Application of HAZUS and ShakeMap for Loss Estimation from a Scenario Earthquake in the Korean Peninsula (지진재해예측을 위한 HAZUS와 ShakeMap의 한반도에서의 적용가능성 연구)

  • Kang, Su Young;Kim, Kwang-Hee;Kim, Dong Choon;Yoo, Hai-Soo;Min, Dong-Joo;Suk, Bbongchool
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.1
    • /
    • pp.47-59
    • /
    • 2007
  • Efficiency and limitations of HAZUS-MH, a GIS based systematic and informative system developed by FEMA and NIBS for natural hazard loss estimations, are discussed by means of a pilot study in the Korean Peninsula. Gyeongsang-do has been selected for the test after careful reviews of previous studies including historical and modern seismicity in the peninsula. A ShakeMap for the selected scenario earthquake with magnitude 6.7 in Gyeongju area is prepared. Then, any losses due to the scenario event have been estimated using HAZUS. Results of the pilot test show that the study area may experience significant physical, economic, and social damages. Detailed study in the future will provide efficient and crucial information to the decision makers and emergency agents to mitigate any disaster posed by natural hazards.

  • PDF

Study on the Prevention and Combat System of Oil Pollution in Germany (독일의 해상유류오염 예방 및 방제체계 고찰)

  • Shin, Ok-Ju
    • Journal of Environmental Policy
    • /
    • v.8 no.1
    • /
    • pp.97-127
    • /
    • 2009
  • In Germany, North Sea and East Sea possess significant meaning in many aspects. North coast has an important economical significance to North Sea Gulf States. There are a number of harbors and manufacturing facilities in this area. Agriculture is also developed. East sea, where sea water and river water mingle. has a problem that it can not control harmful substances as fast as the North Sea due to its geographical location of being connected with the North Sea as a narrow water. To protect from big and small ship accidents and pollution sources, East Sea and North Sea have enacted HELKOM Convention and OSPAR Convention, respectively. Moreover, Denmark and Germany have made cooperation on tugboats in the occurrence of shipment accidents through the LethGer-Plan and DenGer-Plan. In 1998, after the Pallas accident that occurred near Bremen, the need to improve cooperation among each states on usable resources for ocean security has been increased in Germany. Consequently, the federal government and gulf state governments associated and organized the so called, "Havarie-Kommanando Ship Accident Measure Unit". Haravarie-Kommanando is a federal-state associated organization that deals with affairs that controls national operation and mobilization of ship accident related organizations unitively when serious ship accidents occur. Moreover, federal and state participant organizations, each shipping agencies and Wiking-Helicopers-Services, a helicopter agency, are cooperating well. Also, mutual assistance with the most prominent passenger agency called Scandlines, ARGE Kuestenschutz(Germany-Denmark shipping agency) is making progress as well.

  • PDF

Delayed use of Operating Rooms in a University Hospital (한 대학병원의 수술실 이용 지연요인과 개선방안에 관한 연구)

  • Kim, Kyung-Ae;Yu, Seung-Hum;Kim, In-Sook;Sohn, Tae-Yong;Park, Eun-Cheol
    • Korea Journal of Hospital Management
    • /
    • v.7 no.3
    • /
    • pp.44-62
    • /
    • 2002
  • Advanced surgical technology demands more precise, meticulous, and time-consuming procedures. In addition, the patient's preference of tertiary health providers makes over crowding of the University Hospitals. Therefore, it has been necessary to maximize utilization of the operating room of such hospitals to accommodate these requirements. This study, targeting 1,302 surgical cases performed in 22 operating rooms at a university hospital in Seoul from October 8 to November 1, 2001, analyzed reasons for delay, and factors that caused delayed use of operating rooms. This study also assessed that the rate of operating room use would increase if the sources for possible reform were improved. 1. Among total of 1,302 cases of surgery, the incidence of surgeries in which there were no time delays and no factors for delay were discovered is 71.4% or 930 cases: the incidence in which surgeries were delayed was 28.6% or 372 cases. 2. As results of logistic regression for delay, procedures involving women were delayed 1.4 times more frequently than those of men. Compared to Department A, Department B was 1.8 times more likely to be delayed, and Department H was 0.4 times less likely to be delayed. Regional anesthesia was 2.4 times more likely to be delayed than general anesthesia, and surgeries that PCA was applied were 0.6 times less likely to be delayed than those when it was not. Surgeries performed on the Thursday were 1.7 times more likely to be delayed than those performed on the Monday. Compared to surgeries performed between 07:00-07:59, those performed between 08:00-08:29 were 4.3 times higher. 3. The reasons for delay were related to surgeon, surgical department, patient, anesthesia, administrative system, sick ward, and support services. Among these, 5,755 minutes for 276 delayed cases could be resolved easily, and resolving delays of 3,320 minutes for 131 cases would be more difficult. Among the causes for delay that could be improved, delays due to patient's transfer and surgeon's factor were the most common, 21.6% and 17.4% respectively. 4. If resolvable delays are improved, pre-anesthesia room is administered, and regional anesthesia and PCA are done ahead of time, use of emergency operating rooms will increase, we can increase overall utilization by 4.09%, we will save 744 minutes a day, we can reduce the time the operation room is used after 4 PM by 35%, and we can resolve the operation cancellations due to insufficient operating rooms. For the increase in the use of operating rooms, we need to maximally decrease the delays that could be improved, by allocating block time based on used totals hours of elective cases, giving accurate information on surgery schedule, voluntary cooperation by staff participating in surgeries in reducing delay time, and the hospital management's will to improve delay.

  • PDF

Behavior of Fire Resistance Engineered Cementitious Composites(FR-ECC) under Fire Temperature (화재 온도를 받는 고인성.고내화성 시멘트 복합체의 거동)

  • Han, Byung-Chan;Kwon, Young-Jin;Kim, Jae-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.189-197
    • /
    • 2007
  • Concrete tunnel lining must be designed to having the fireproof performance because the lining are sometimes exposed to very high temperature due to traffic accident. Such fire temperature may cause explosion of concrete, or collapse of tunnel structure. The purpose of this study is to obtain the fundamental fireproof behavior of fire resistance-engineered cementitious composites(FR-ECC) under fire temperature in order to use the fire protection material in tunnel lining system. The present study conducted the experiment to simulate fire temperature by employing 2 types of FR-ECC and investigated experimentally the explosion and cracks in heated surface of these FR-ECC. Employed temperature curve were hydro carbon(HC, ECl) criterion, which are severe in various criterion of fire temperature. The numerical analysis is carried out the nonlinear transient heat flow analysis and verified against the experimental data. The complex features of behavior in fire conditions, such as thermal expansion, plasticity, cracking or crushing, and material properties changing with temperature are considered. By the use of analytical model, the concrete tunnel subjected to fire loads were analyzed and discussed. With comparison of current concrete materials and FR-ECC, the experimental and analytical results of FR-ECC shows the better fire resistance performance than the other.

Dynamic Characteristics on the CRDM of SMART Reactor (SMART 원자로 제어봉 구동 장치의 동특성해석)

  • Lee, Jang-Won;Cho, Sang-Soon;Kim, Dong-Ok;Park, Jin-Seok;Lee, Won-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1105-1111
    • /
    • 2010
  • The Korea Atomic Energy Research Institutes has been developing the SMART (System integrated Modular Advanced ReacTor), an environment-friendly nuclear reactor for the generation of electricity and to perform desalination. SMART reactors can be exposed to various external and internal loads caused by seismic and coolant flows. The CRDM(control rod drive mechanism), one of structures of the SMART, is a component which is adjusting inserting amount of a control rod, controlling output of reactor power and in an emergency situation, inserting a control rod to stop the reactor. The purpose of this research is performing the analysis of dynamic characteristic to ensure safety and integrity of structure of CRDM. This paper presents two FE-models, 3-D solid model and simplified Beam model of the CRDM in the coolant, and then compared the results of the dynamic characteristic about the two FE-models using a commercial Finite Element tool, ABAQUS CAE V6.8 and ANSYS V12. Beam 4 and beam 188 of simplified-model were also compared each other. And simplified model is updated for accuracy compare to 3-D solid.

Fire Service Policy Theory for Establishing Fire Science (소방학의 학문적 정체성 확립을 위한 소방정책론 정립방안)

  • Ryu, Sang-Il;Lee, Jae-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.421-432
    • /
    • 2010
  • In Korea, about 80 academic departments related to fire science are in operation throughout the country, but fire science is not included as a branch science in the science classification system acknowledged by the Ministry of Education, Science and Technology and its position as a science is not solid yet. In response to this problem, research is being made actively to establish fire science recently. This study aims at composing the fire service policy theory which is one of sub areas of fire science. First, the concept of fire service policy should be established, and fire service policies should be divided into different types. In addition, it is necessary to examine the direction of the development of fire service policies in Korea, and the unique characteristics of fire service policies should be described. Next, we will mention fire service policy making and participants, theories on the determinants of fire service policies, the execution of fire service policies, and the evaluation of fire service policies. Particularly, based on the peculiarity of fire service, it is necessary to explain policies on fire prevention and precaution, fire investigation, rescue and first aid, public campaigns for safety and prevention, fire insurance, etc. Finally, we suggest the future directions of fire service policies according to the change of environment in the future.

A Study on Practical Analyzing and Improving Disaster Management Organization of Korean Government (재난관리조직의 실태분석과 발전방안)

  • 권오한;남상화;이춘하
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.127-138
    • /
    • 2001
  • I. introduction. A government goal at the present is established to make a welfare nation and to keep people's safe living, but it is criticised that when a large-scale disaster happens, the authority concerned could not deal with it, causing many people injured and material damage. Moreover, in these days, cities have many risk factors. extremely large and intelligent building, industrial facilities and underground equipment have many risk themselves along with scientific progress. The cope with disaster effectively, government must have efficient organization, skillful personnel, tool, facilities and so on. To reduce the damages, what's the most effective government organization\ulcorner II. Government organization for managing disaster In a few decades, a large-sized accidents broke out in korea, for example, collapse of Sampoong department store, break of Sungso bridge, explosion of Daegu city gas, gas explosion accident at Ahyon-dong etc. but government has not any adequate disaster response organization. Especially, after collapse of Sampoong department store broke out, Disaster Management Act is enacted to solve the past problem. According to Disaster management Act, disaster is limited in manmaid disaster. Therefore, in this thesis, disaster management is inspected theoretically, organization of disaster management for pattern of disaster, and role, duty of government organization, emergency relief organization system and actual conditions are analyzed. there are some problems. there are trials and errors. the government has changed the disaster management organization by the disaster management law. the organization consists of central and local government. but both of government do not work together harmoniously. in thesis, I would like to introduce the advanced nations disaster management organization, and study our central, local government organization. III. Conclusion Change and development of the government disaster management organization is the goal of this thesis. we have to increase public service in response and manage disaster. protecting civilian's life from the disaster is very important responsibility of government. there would be better way of government disaster management organization.

  • PDF

A Study on the Selection of Target Ship for the Protection of Submarine Power Cable (해저 동력케이블 보호를 위한 대상 선박 선정에 관한 연구)

  • Lee, Yun-sok;Kim, Seungyeon;Yu, Yungung;Yun, Gwi-ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.662-669
    • /
    • 2018
  • Recently, the installation of submarine power cables is under consideration due to the increase of electric power usage and the development of the offshore wind farm in island areas, including Jeju. In order to protect power cables installed on the seabed, it is necessary to calculate the burial depth based on the characteristics of anchoring, dragging and fishing, etc. However, there is no design standard related to the size of target ships to protect the cables in Korea. In this study, we analyzed the design standards for the protection of domestic submarine pipelines similar to submarine cables, and developed the risk matrix based on the classification by emergency anchoring considering the installation environment, then designed the size of target ships according to the cumulative function scale by ship size sailing through the sea concerned. Also, we linked marine accident conditions, such as anchoring, dragging, etc. and the environmental conditions such as current, sea-area depth of installation etc. to the criteria of the protection of submarine cable, and examined the size of specific target ships by dividing the operating environment of ships into harbor, coastal and short sea. To confirm the adequacy and availability of the size of target ships, we verified this result by applying to No. 3 submarine power cables, which is to be installed in the section from Wando to Jeju Island. This result is expected to influence in the development of a protection system for submarine cables and pipelines as well as the selection of anchor weight according to the determination of burial depth.