• Title/Summary/Keyword: Emergency Storage

Search Result 148, Processing Time 0.023 seconds

Emergency Medical System based on GIS (GIS(Geographic Information System ) 을 이용한 응급의료 진료관리 시스템 개발)

  • 이태식;구지희
    • Spatial Information Research
    • /
    • v.4 no.1
    • /
    • pp.43-54
    • /
    • 1996
  • The purpose of this study is to provide GIS application to the emergency medical service management system in the Seoul area. Two wards, Kangnam-Gu and Songpa-Gu, were selected for a pilot study subject. The main focus of the study was to develope the network system using GIS which could select the most available hospital from the site being emergency case and advise the minimum path to the hospital. ARC/INFO pc version was need to implemeni an indexing system for automated mapping and data storage. The developed system, "Emergency Medical System based on GIS ${\ulcorner}$EMS/GIS${\lrcorner}m$", consists of the cartographic database and vehicle transportation system. The results suggest that EMS/GIS network are needed to connect the local transportation network between major emergency care hospitals and central conirol tower in the near future. If the EMS/GIS system could be more developed based in further analysis, it would be the most useful economical and efficient for emergency medical service with mutual aid system.al aid system.

  • PDF

Economic Evaluations of Secondary Battery Energy Storage Systems in Power Distribution Systems (전력저장전지시스템의 경제성 평가)

  • No, Dae-Seok;O, Yong-Taek
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.4
    • /
    • pp.152-160
    • /
    • 2000
  • This paper presents an efficient evaluation method on the role of new energy storage systems, especially the secondary Battery Energy Storage (BES) systems, in the case where they are interconnected with the power distribution systems. It is important to perform the economic evaluation for the new energy storage systems in a synthetical and quantitative manner, because they are very costly in the early stage of their development and commercialization. In this paper, the multiple functions of BES systems, which are operated at distribution systems, such as load levelling, effective utilization of power distribution systems and uninterruptible power supply at the emergency conditions are classified and analyzed. And then the quantitative evaluation methods of the multiple functions for BES systems are proposed using the mathematical modelling.

  • PDF

A Study on the Elderly Households' Needs for Housing Modification (노인가구 특성에 따른 주거개조요구에 관한 연구)

  • Lee, Kwang-Soo;Park, Soo-Been
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.278-283
    • /
    • 2009
  • This study aims to figure out the old people's needs for modification of their housing to maintain an independent lifestyle despite their health status and living arrangements. The total of 438 residents take part in the questionnaire survey research through the quota sampling method grouped by age (60-64 group, 65-69 group, 70-74 group, and over 75 group), sex (male and female), and house type (apartment houses and others). The results are as follows. (1) The old people's most inspired modification needs in interior spaces are remodeling the heating controls in the living room and the bedroom, ventilation facilities and storage spaces in the kitchen, non-slip tile flooring and ventilation facilities in bathroom, an easy door-lock, non-slip tile flooring, a draft cut-off, and storage spaces in the entrance. Besides they require emergency alarm, easy door and window locks, fire and gas alarm, and furniture with easy handling. It is necessary to supply the aged with the appropriate heating controls for their sensitivity to heat, with enough storage spaces for the increased possessions, and with diverse safety systems reflected blunting of mobility and sensibility. (2) As they grow older, the aged require more remote controls and safety facilities such as emergency alarm, easy locks and furniture with distinguishable colors. Male elderly is more concerned with safety, while female elderly do with convenience due to their different time spending in the house. The elderly residents in the apartment houses require the heating controls, a draft cut-off, and storage space less than other types of houses. Thus modification of the heating controls, a draft cut-off, and storage space are regards as basic needs for the elderly residents in non-apartment houses.

  • PDF

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

The Utilization of Energy Storage System(ESS) as Emergency Power Source for Nuclear Power Plant (원자력 발전소 비상전원으로써 ESS의 활용)

  • Lee, Woo-Rim;Chang, Choong-koo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.641-642
    • /
    • 2015
  • 에너지저장장치(Energy Storage System, ESS)는 생산된 전력을 전력계통에 저장했다가 전력이 가장 필요한 시기에 꺼내어 사용함으로써 에너지효율을 높이는 능동적인 기술이다. ESS는 풍력발전, 태양광발전 등 신재생에너지와 같은 분산전원 도입, 피크부하에 대응하기 위한 부하평준화, 전력품질개선 등 그 역할과 기능이 확대되고 있다. 본 논문에서는 후쿠시마 사고 이후 강조된 비상전원과 관련하여 원자력발전소 부지 내 비상전원으로써의 ESS 활용과 그 가능성에 대해서 기술하였다.

  • PDF

Simulation Analysis and Development of Matlab/Simulink Model for Stand-alone Operation of Emergency Diesel Synchronous Generator-based Hybrid Energy System (비상용 디젤동기발전시스템기반 독립운전 하이브리드에너지시스템 모델 설정 및 시뮬레이션 분석에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.70-79
    • /
    • 2015
  • In this paper, enhanced stand-alone operation and development of Matlab/Simulink model of emergency diesel based hybrid energy system is presented. Simulations based on the remote community or islands were performed for PV-diesel-battery hybrid system. Modeling of PV-diesel-battery integrated system is done to perform under the solar radiation and load conditions on Matlab/Simulink platform. The models of diesel generator unit, battery energy storage system, PV and frequency-power control are developed and simulation studies have been carried out under various conditions using Matlab/Simulink and SimPowerSystem. It is demonstrated that the proposed system can provide reliable and good quality power to the customers in diesel synchronous generator-based hybrid energy systems.

Mobile Receiver Model for T-DMB Location Automatic Emergency Alert Service (T-DMB 국지적 자동재난경보방송 서비스를 위한 모바일 수신 모델)

  • Kwon, Seong-Geun;Jeon, Hee-Young;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10A
    • /
    • pp.796-806
    • /
    • 2009
  • This paper presents the method of emergency warning system operation based on T-DMB and the design of T-DMB AEAS receiver model. The proposed receiver model compares the geographical location of emergency with the location of DMB transmitting station from T-DMB broadcasting signal and classifies the receiver location into alert region, neighboring region and non-alert region and transmits the emergency alert message according to each region. The geographical location of emergency can be obtained from FIG 5/2 EWS data field for AEAS message and the location of DMB transmitting station can be estimated from either the latitude and the longitude in main identifier and sub identifier in FIG 0/22 data filed for TII(Transmitter Identification Information) or TII distribution database. In our experiment, we implemented the proposed receiver model with display section, storage section, DMB module for receiving broadcasting signal and control section and performed test emergency alert broadcasting using T-DMB signal generator.

Unintentional Pharmaceutical Poisoning in the Emergency Department (응급실로 내원한 비의도적 의약품 중독)

  • Jo, Hyo Rim;Lee, Choung Ah;Park, Ju Ok;Hwang, Bo Na
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.16 no.2
    • /
    • pp.116-123
    • /
    • 2018
  • Purpose: The social environment of easy access to medicines and arbitrary personal decisions leading to overdose aggravate unintentional medicine poisoning. This study aimed to investigate the characteristics of patients who visited emergency departments with unintentional medicine poisoning and reasons for poisoning based on age group. Methods: We retrospectively collected patients who experienced unintentional medicine poisoning based on data from the national injury surveillance system between 2013 and 2016. Subjects were classified into three groups based on age (0-14 years, 15-64 years, and ${\geq}65\;years$). We identified sex, insurance, time of poisoning, place, alcohol co-ingestion, hospitalization, death, and reason for poisoning in each age group. Results: A total of 27,472 patients visited an emergency department with poisoning during the study period; 1,958 patients who experienced unintentional poisoning were enrolled in this study. Respiratory medicine was the most frequent medicine in those younger than 15 years of age, and sedatives and antipsychotic drugs were the most common in patients older than 15 years of age. In total, 35.1% of patients older than 65 years were hospitalized. The most common reasons for poisoning were careless storage of medicine in those younger than 15 years of age and overdose due to arbitrary decisions in those older than 15 years of age. Conclusion: Unintentional medicine poisoning has distinct characteristics based on age group, and strategies to prevent poisoning should be approached differently based on age.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

Development of 3kW Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발)

  • Yang, Seok-Hyun;Kim, Min-Jae;Choi, Se-Wan;Cho, Jun-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.