• Title/Summary/Keyword: Emergency Power Equipment

Search Result 87, Processing Time 0.022 seconds

Characteristics of Energy Consumption in an Office Building located in Seoul (사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성)

  • Park Byung-Yoon;Chung Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

An Analysis of the Relationship between Elevator Emergency(Entrapment) and Situation Measurement of Sag/Interruptions at the Switchboard

  • Kim, Gi-Hyun;Lim, Young-Bae;Bai, Seok-Myung;Kim, Jae-Chul;Lee, Hee-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.36-44
    • /
    • 2007
  • This study researched the mutual relationship between elevator emergencies(sudden stops, entrapment) and power quality such as voltage interruptions or sags. To analyze the power quality at the elevator switchboard of an apartment, the on-line power quality(sag, swell, and interruption, etc.) were measured and error messages(under voltage error, etc.) in the elevator control room were researched. Also the performance and susceptibility for stops were evaluated and stated through the testing of three pieces of simulated test equipment with an EN12016(2004) standard setting and the magnitude and duration data of the measured sag or interruption. This paper will use these data in the analysis of the mutual relationship between power quality and elevator emergencies.

A Control Method for Power-Assist Devices using a BLDC Motor for Manual Wheelchairs

  • Kim, Dong-Youn;Kim, Yong-Hyu;Kim, Kwang-Sik;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.798-804
    • /
    • 2016
  • This paper proposes a new operation and control strategy for Power-Assisted Wheelchairs (PAW) using one brushless DC (BLDC) motor. The conventional electrical wheelchairs are too heavy and large for one person to move because they have two electric motor wheels. On the other hand, the proposed PAW system has a small volume and is easy to move due to the presence of a single wheel motor. Unlike the conventional electric wheelchairs, this structure for a PAW does not have a control joystick to reduce its weight and volume. To control the wheelchair without a joystick, a special control system and algorithm are needed for proper operation of the wheelchair. In the proposed PAW system uses only one sensor to detect the acceleration and direction of PAW's movement. By using this sensor, speed control can be achieved. With a speed control system, there are three kinds of operations that can be done on the speed of a PAW: the increment of PAW speed by summing external force, the decrement of PAW speed by subtracting external force, and emergency breaking by evaluating the time duration of external force. The validity of the proposed algorithm is verified through experimental results.

Proposed measure for Smart Grid's Personal Information Security Issue (스마트 그리드 개인정보 보안이슈 방안 제시)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.41-49
    • /
    • 2016
  • Smart Grid is a next generation of new power growth electrical grid which provide high quality of electrical service by using Information Technologies to increase intelligence and performance. By using Smart Grid system, it can support energy management such as increase quality of electrical power, decrease energy and decrease emissions. However, Smart Grid uses information of energy consumption and when Smart Grid collects information, it will create private information. In this thesis, it will address issues of security private information which caused by Smart Grid for administrative measure and efficiency of Smart Grid in domestic. Also, cryptographic module algorithm, latest security solutions and strong wireless security policy for network environment such as wireless communication Iinternet are require for Smart Grid perform successfully and protect national power network equipment from cyber-attack and can stop leakage of user's personal information. Finally, it is urgent to prepare protection measures of National industrial facilities and power grid which can prepare for a cyber terrorism and penetration attacks and build emergency countermeasure management team for Smart Grid are require for safe Smart Grid environment.

Shock Analysis of Mobile Power Supply Container for Radar with MIL-STD-810H (MIL-STD-810H를 적용한 레이더 전력공급용 이동식 컨테이너의 충격해석)

  • Kwon, Jaeeon;Shin, Dongwon;Hur, Jangwook
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.569-576
    • /
    • 2021
  • Radar is a ground defense system that detects enemy aircraft and receives power from a mobile power supply in an emergency. Serious problems may occur if the equipment is damaged by impact during transportation for use. The US military standard MIL-STD-810H contains information on environmental tests such as shock and vibration applied to munitions. Therefore, in this study, the transient analysis of ANSYS 19.2 was performed using the impact data specified in MIL-STD-810H as an input value. Through this, the maximum stress generated in the impact environment of the mobile power supply container was derived, and the safety margin was calculated to confirm the reliability of the container.

Design and Evaluation of PMU Performance Measurement and GPS Monitoring System for Power Grid Stabilization

  • Yang, Sung-Hoon;Lee, Chang Bok;Lee, Young Kyu;Lee, Jong Koo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • Power grid techniques are distributed over general power systems ranging from power stations to power transmission, power distribution, and users. To monitor and control the elements and performance of a power system in real time in the extensive area of power generation, power transmission, wide-area monitoring (WAM) and control techniques are required (Sattinger et al. 2007). Also, to efficiently operate a power grid, integrated techniques of information and communication technology are required for the application of communication network and relevant equipment, computing, and system control software. WAM should make a precise power grid measurement of more than once per cycle by time synchronization using GPS. By collecting the measurement values of a power grid from substations located at faraway regions through remote communication, the current status of the entire power grid system can be examined. However, for GPS that is used in general national industries, unexpected dangerous situations have occurred due to its deterioration and jamming. Currently, the power grid is based on a synchronization system using GPS. Thus, interruption of the time synchronization system of the power system due to the failure or abnormal condition of GPS would have enormous effects on each field such as economy, security, and the lives of the public due to the destruction of the synchronization system of the national power grid. Developed countries have an emergency substitute system in preparation for this abnormal situation of GPS. Therefore, in Korea, a system that is used to prepare for the interruption of GPS reception should also be established on a long-term basis; but prior to this, it is required that an evaluation technique for the time synchronization performance of a GPS receiver using an atomic clock within the power grid. In this study, a monitoring system of time synchronization based on GPS at a power grid was implemented, and the results were presented.

Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction (에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용)

  • Lim, Il-Hyung;Lee, Myung-Hwan;Shin, Yong-Hark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

A Study on Design and Implementation of the Test Bench for Standard Performance Measurement of Satellite EPIRB (위성 EPIRB 표준 성능측정을 위한 Test Bench의 설계 및 구현에 관한 연구)

  • 임종근;김기문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.554-562
    • /
    • 2004
  • It was recommended for all ship engaged in international voyages to carry the Satellite Emergency position Indicating Radio Beacon according to Global Maritime Distress & Safety System but also it is tending to be diffused to require the satellite EPIRB installed in small vessel such as a fishery boat by domestic regulations of each countries. Otherwise the domestic regulation can't evaluate exactly the compatibility with the satellite system and the performance of the equipment itself required by international regulation. And even if it is required the performing of the performance inspection in accordance with international regulation, it is difficult to grasp the characteristics of equipment by a generalized measuring equipment. Hence this study performed the measurement for the matters related with an wave forms, modulation characteristics, frequency and the power, etc through the design and implementation of the test bench capable of ensuring most of test items regulated by international regulation. Through this study, it has been paved the way being capable of preparation of the standard regarding to transmission repetition period, phase variation and frequency stability related with the system compatibility and in conclusion, it is enable to improve the performance of a main distress communication equipment directly connected with the life of a survivor.

Real-time Natural Disaster Failure Analysis Information System Development using GIS Environment (GIS환경의 실시간 자연재해정보를 연계한 재해고장분석시스템 개발)

  • Ahn, Yeon-S.
    • Journal of Digital Contents Society
    • /
    • v.10 no.4
    • /
    • pp.639-648
    • /
    • 2009
  • Earth's environment issues are introduced recently and every year the social loss have been occurred by the impact of various disaster. This kind of disaster and weather problems are the increasing reason of electricity transmission network equipment's failures because of exposing by the natural environment. The emergency and abnormal status of electricity equipment make the power outage of manufacturing plant and discomfort of people's lives. So, to protect the electricity equipment from the natural disasters and to supply the power to customer as stable, the supporting systems are required. In this paper, the research results are described the development process and the outcomes of the real-time natural disaster failure analysis information system including the describing about the impact of disaster and weather change, making the natural weather information, and linking the realtime monitoring system. As of development process, according to application development methodology, techniques are enumerated including the real time interface with related systems, the analysing the geographic information on the digital map using GIS application technology to extract the malfunction equipment potentially and to manage the equipments efficiently. Through this system makes remarkable performance it minimize the failures of the equipments, the increasing the efficiency of the equipment operation, the support of scientific information related on the mid-term enhancement plan, the savings on equipment investment, the quality upgrading of electricity supply, and the various supports in the field.

  • PDF

Evaluation of Vibration Characteristics of Operating Rotational Machines Depending of Types of Foundation (기초형식에 따른 회전기기의 가동중 진동특성 분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.63-72
    • /
    • 2007
  • The Emergency Diesel Generator (EDG) is a very important equipment for the safety of a Nuclear Power Plant (NPP). In this study, the operating vibration of three kinds of EDG systems was measured. The target EDG systems are Yonggwang 5 unit and Ulchin 2 and 3 units. The Yonggwang 5 and Ulchin 3 unit EDG systems are the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of these measurements is for a verification of the vibration isolation effect depending on the foundation system. As a result, It can be said that the spring and viscous damper system of the EDG performed better for the vibration isolation than that of anchor bolt type.