• Title/Summary/Keyword: Emergency Lamp

Search Result 31, Processing Time 0.023 seconds

Remote control of ship's emergency lighting system (선박 비상조명 시스템의 원격제어)

  • Lim, Hyun-Jung;Yang, Hyun-Suk;Kim, Kun-Woo;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.252-253
    • /
    • 2005
  • This paper describes a improvement of power control characteristics of ship's emergency lighting power supply(SELPS), that power factor(PF) is improved and electric power is controlled extensively, and power ON-OFF is controlled and system parameter monitored in remote distance by PC serial communication.

  • PDF

Development of Multi LED type Door Status Indication Lamp for rolling stock (Multi LED를 이용한 철도차량용 Door Status Indication Lamp)

  • Seo, Bum-Won;Choi, Jae-Sung;Kim, Dong-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1668-1674
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF

Development of Multi LED type Door Status Indication Lamp for rolling stock (Multi LED를 이용한 철도차량용 Door Status Indication Lamp)

  • Seo, Bum-Won;Choi, Jae-Sung;Kim, Dong-Il
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1466-1472
    • /
    • 2011
  • Door Inside Lamp of railway rolling stock is installed on interior of the side doors and illuminated at door opening and closing, isolation and fault. So drivers or passengers can notice the door status visually. In the past, a single color or Bi-color LED Lamps have been using and one ~ multiple lamp was used to implement the feature according to client's requirements. (Example: Total of between 2 and 4 lamps are required for the Warning / Emergency operation / Isolation / Fault.) However these design is not easy to apply if there is the mounting space restrictions and the problems such as rising costs can be caused. In addition, it has vulnerability from point of view aesthetic aspects. Therefore the lamp type has been required that has small size and number of colors in order to resolve these problems. Recently multi LED type door status indication lamp have been developed that can meet the requirements and this lamp has been applied in many railway projects. In this study, I'll introduce the general characteristics and mechanical & electrical characteristics of multi LED type door status indication lamp to help development of this kinds of lamp.

  • PDF

Multi Remote Control of Ship's Emergency Lighting Power Supply (선박 비상조명 전원장치의 다중 원격제어)

  • Lee Sung-Geun;Lim Hyun-Jung
    • Journal of Navigation and Port Research
    • /
    • v.29 no.10 s.106
    • /
    • pp.859-863
    • /
    • 2005
  • This paper describes the improvement of power control characteristics of ship's emergency lighting power supply(SELPS), by which electric power is controlled extensively, and power ON-OFF is controlled and system parameter monitored in remote distance by PC serial communication. Proposed system is composed of step-down converter(SDC), emergency power supply circuit(EPSC), half bridge(HB) inverter, fluorescent lamp(FL) starting circuit, microprocessor control and multi communication circuit. Experimental works confirm that relative system stops when over current is detected and speedy and stable emergency power is supplied when main power source cut-off, and controls input power up to 35[$\%$] by adjusting pulse frequency of the HB inverter, and ON-OFF control of multiple SELS, real time transmission and monitor of parameters as to voltage, current, and power values are performed appropriately by PC communication.

The study of Connection Emergency lantern with Fire Alarm System (자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구)

  • Chun, Jung-Ham;Lee, Sang-Hwa;Kwon, Oh-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF

A Study on the Improvement of Performance of Power Supply for Ship's Emergency Lighting System (선박 비상조명용 전원장치의 성능개선)

  • Yang Hyun-Suk;Lee Su-Hun;Jeong Tae-Sun;Lee Sung-Geun;Kim Yoon-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.822-825
    • /
    • 2004
  • This paper describes the improvement of performance of power supply for ship's emergency lighting system(SELS). Proposed system is composed of power factor correction (PFC) circuit, emergency power supply system (EPSS), half bridge(HB) inverter, fluorescent lamp(FL) starting circuit and microprocessor control system. Experimental works using proposed system confirm that speedy and stable power to be supplied when main power source cut-off, compared with conventional relay type, and control power factor up to $97.5[\%]$ and input power up to $35.0[\%]$ by adjusting of pulse frequency of the HB inverter.

  • PDF

A Study on the Remote Monitoring and Control of Ship's Emergency Lighting System (선박 비상조명 원격 모니터링 제어)

  • Yang, Hyun-Suk;Kim, Kun-Woo;Lim, Hyun-Jung;Moon, Jung-Pil;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.207-210
    • /
    • 2005
  • This paper describes a design of several ship's emergency lighting system(SELS) that power factor is improved and power is controlled extensively, and techniques to control and monitor this system in remote distance by PC serial communication. The remote monitoring control system is composed of emergency power supply system (EPSS), half bridge(HB)inverter, fluorescent lamp(FL), microprocessor, multi communication interface. EPSS checks the voltage of the emergency backup battery in real time. In case that the voltage of 13[V] or less has been detected for 5[msec] or longer for 3 times in a row, charger circuit is connected for battery charging. Experimental works using proposed system confirm that speedy and stable power to be supplied when main power source cut-off, compared with conventional analog type, and input power up to 35.0[%] by adjusting of pulse frequency of the HB inverter.

  • PDF

A Study on Improvement of Operation Characteristics and Inspection Method of Standby Power Supply such as Emergency Induction Light using Li-ion Capacitor (리튬이온커패시터를 활용한 비상유도등 예비전원장치의 동작 특성 및 점검방법 개선에 관한 연구)

  • Jung, Jun-Chea
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.392-401
    • /
    • 2020
  • Purpose: This study analyzes the operating characteristics of a lithium ion capacitor that can be used as a standby power supply in an emergency, and determines whether the standby power supply is abnormal even by measuring the voltage using a linear proportionality characteristic during charging and discharging. The aim is to provide an experimental basis that can be done. Method: As a method for this study, first, analyze the operation principle and characteristics of the existing backup power supply and lithium ion capacitor, and then measure the voltage of the lithium ion capacitor according to the configuration and system block diagram of the induction lamp used in the experiment. We proceed with the test of the measured value of discharge power for each voltage band to check the amount of power held by the battery and the operation test experiment using induction lamps. Results: Just by checking the charging voltage using the linear proportional characteristics of lithium ion capacitors, it provides a basis for accurately inferring the effective operating time of induction lamp lamps. Conclusion: In the event of a disaster, the lithium ion capacitor is used as a spare power supply for emergency induction lamps to prevent complete discharge of emergency induction lamps, to prevent the problem of performing normal operation of the standby power supply, and to use only a simple voltage measurement to reserve power. It was intended to suggest many uses for evacuation equipment application in the future by making it possible to check whether the device is abnormal.

A Study on the Photovoltaic System of power supply for Outdoor and emergency lamp at APT (APT 외등 비상등 전원 공급등 태양광 시스템에 관한 연구)

  • 박종복;임중열;차인수;정명웅;이만근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.170-176
    • /
    • 1998
  • The objective of the research project is the practical application of solar lighting system to apartment. This system is composed of solar cell, battery system, inverter, and a grid-connected circuit. This experimental results are recognized to us that the research results, which was developed but not applied, is able to improve the effect by expanding their utilization. We will utilize this system continuously as public relation.

  • PDF

Design of Ballast for a turning on a lamp in both common use and emergency (상용/비상 겸용 형광등 안정기 개발)

  • Jun, Kwang-Ho;Song, Soo-Min
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.217-219
    • /
    • 2004
  • 종래의 비상 조명 장치로는 배터리 충전 회로를 이용하는 방법이 있으며 이는 정상적으로 전원이 공급되지 않는 한 배터리가 완전히 방전될 때까지 배터리와 비상 점등 회로가 연결되어 배터리의 과방전을 초래하고, 더 나아가 배터리의 특성상 과충전이나 과방전상태에 도달하여 배터리가 손상되어 사용할 수 없는 경우가 발생하기도 한다. 본 연구는 상기와 같은 종래 기술의 제반 단점과 문제점을 해결하기 위한 것으로, 상용시뿐만 아니라 기타 비상시에도 형광등에 전원이 공급되도록 하는 안정기를 개발하는 것을 목적으로 한다.

  • PDF