• Title/Summary/Keyword: Embedded length

Search Result 451, Processing Time 0.031 seconds

Estimation of Prestressed Tension on Grouted PSC Tendon Using Measured Elastic Wave Velocity (응력파속도를 이용한 부착식 PSC 텐던의 긴장력 추정)

  • Kim, Byeong Hwa;Jang, Jung Bum;Lee, Hong Pyo;Lee, Il Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.289-297
    • /
    • 2012
  • This study proposes an experimental formula that can estimate the applied tensile stress of a bonded PSC by measuring a longitudinal stress wave velocity of tendon. To develop practical formula, the various bonded PSC specimens are constructed with different levels of prestresses. For all the bonded PSC specimens, the longitudinal impact-echo tests are repeated with various experimental conditions. Considering a few influence factors such as temperature, length and the number of strands, the application of the law of similarity results in a nondemensional experimental formula that could estimate existing tensile stress on tendon by measuring its longitudinal stress wave velocity. Next, a feasibility study of proposed approach has been conducted for a real reactor building containment. The estimated stress levels of two vertical tendons embedded in the nuclear plant are close to their design values.

Novel Fabrication and Testing of a Bubble-Powered Micropump (새로운 기포동력 마이크로펌프 제작 및 실험)

  • Jung, Jung-Yeul;Kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1196-1200
    • /
    • 2004
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. In this study, a bubble-powered micropump was fabricated and tested. The micropump consists of two-parallel micro line heaters, a pair of nozzle-diffuser flow controller and a 1 mm in diameter, 400 ${\mu}m$ in depth pumping chamber. The two-parallel micro line heaters with 20 ${\mu}m-width$ and 200 ${\mu}m-length$ were fabricated to be embedded in the silicon dioxide layer of a wafer which serves as a base plate for the micropump. The pumping chamber, the pair of nozzle-diffuser unit and microchannels including the liquid inlet and outlet port were fabricated by etching through another silicon wafer. A glass wafer (thickness of $525{\pm}15$ ${\mu}m$) having two holes of inlet and outlet ports of liquid serve as upper plate of the pump. Finally the silicon wafer of the base plate, the silicon wafer of pumping chamber and the glass wafer were aligned and bonded (Si-Si bonding and anodic bonding). A sequential photograph of bubble nucleation, growth and collapse was visualized by CCD camera. Clearly liquid flow through the nozzle during the period of bubble growth and slight back flow of liquid at the end of collapsing period can be seen. The mass flow rate was found to be dependent on the duty ratio and the operation frequency. As duty ratio increases, flow rate decreases gradually when the duty ratio exceeds 60%. Also as the operation frequency increases, the flow rate of the micropump decreases slightly.

  • PDF

Effects of Electrical Stimulation on Wound Healing and Skin Mast Cells in Streptozotocin-Induced Diabetic Rats (스트렙토조토신 유도 당뇨 흰쥐에서 전기자극이 상처치유와 피부 비만세포에 미치는 영향)

  • Jekal, Seung-Joo;Lee, Kyung-Sun;Chung, Ok-Bong;Lee, Jae-Hyoung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.40 no.2
    • /
    • pp.118-128
    • /
    • 2008
  • The aim of this study was to investigate the effect of electrical stimulation on healing of impaired wound and alteration of mast cells in experimental diabetic rats. Thirty male Sprague-Dawley rats were divided into three groups : incision (control), diabetes+incision (diabetes) and diabetes + incision + electrical stimulation (D/ES). Diabetes was induced in rats by streptozotocin (STZ) injection (60 mg/kg, one time) and 20 mm length incision wounds were created on the back after shaving hair. The electrical stimulation rats were treated with a current intensity of 30~50 V at 120 pps and $140{\mu}s$ for 10 days from 3 days after STZ injection. The lesion and adjacent skin tissues were fixed with 10% buffered formalin, embedded with paraffin. For wound healing analysis, hematoxylin-eosin (HE) and picrosirius red staining were performed. Mast cells (MC) were stained with toluidine blue (pH 0.5) and quantified at ${\times}200$ using a light microscope. The density of keratinocyte proliferation and microvessels in skin tissues were analyzed using a computerized image analysis system on sections immunostained with proliferative cell nuclear antigen (PCNA) and ${\alpha}$-smooth muscle actin (${\alpha}$-SMA), respectively. The results showed that the wound healing rate, collagen density and neoepidermis thickness, density of PCNA-positive cells and density of ${\alpha}$-SMA-positive vessels were significantly higher in D/ES rats than in diabetic rats. The density of MCs and degranulated MCs in D/ES rats were also significantly higher than those in diabetic rats. These findings suggest that the electrical stimulation may promote the tissue repair process by accelerating collagen production, keratinocyte proliferation and angiogenesis in the diabetic rats, and MCs are required for wound healing of skin in rats.

  • PDF

Buckling behavior of a single-layered graphene sheet resting on viscoelastic medium via nonlocal four-unknown integral model

  • Bellal, Moussa;Hebali, Habib;Heireche, Houari;Bousahla, Abdelmoumen Anis;Tounsi, Abdeldjebbar;Bourada, Fouad;Mahmoud, S.R.;Bedia, E.A. Adda;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.643-655
    • /
    • 2020
  • In the present work, the buckling behavior of a single-layered graphene sheet (SLGS) embedded in visco-Pasternak's medium is studied using nonlocal four-unknown integral model. This model has a displacement field with integral terms which includes the effect of transverse shear deformation without using shear correction factors. The visco-Pasternak's medium is introduced by considering the damping effect to the classical foundation model which modeled by the linear Winkler's coefficient and Pasternak's (shear) foundation coefficient. The SLGS under consideration is subjected to compressive in- plane edge loads per unit length. The influences of many parameters such as nonlocal parameter, geometric ratio, the visco-Pasternak's coefficients, damping parameter, and mode numbers on the buckling response of the SLGSs are studied and discussed.

Estimation of the effect on the autonomic nervous system using the return-map (리턴맵을 이용한 자율신경계 영향 평가)

  • Jo, Heung-Kuk;Ye, Soo-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2099-2104
    • /
    • 2010
  • In this paper, HRV signal which was appeared RR intervals from ECG was analyzed using return-map during anesthesia. We intended to estimate the depth of anesthesia observing the change of autonomic nervous activity(ANS) because HRV showed change of cardio-vascular system of the body according to state of ANS. Return-map analysis is to reconstruct time series of HRV to phase space after calculating delay time and embedded time. After approximating the signal distribution which was reconstructed in phase space in elliptic, we calculated the lengths of major and minor axises of the elliptic and the values was used to estimate the depth of anesthesia. Stages of the anesthesia were 7 levels to evaluate the depth of anesthesia. At induction stage of strong external stimulation, the length of major and minor axis were statistically high and at the operation stage of non-external stimulation, the values were statistically low. Conclusively, the stages of anesthesia were discriminated by HRV signal mapped in the phase space during operation.

Sliding-DFT based multi-channel phase measurement FPGA system (Sliding-DFT를 이용한 다채널 위상 측정 FPGA 시스템)

  • Eo, Jin-Woo;Chang, Tae-Gyu
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.128-135
    • /
    • 2004
  • This paper proposes a phase measurement algorithm which is based on the recursive implementation of sliding-DFT. The algorithm is designed to have a robust behavior against the erroneous factors of frequency drift, additive noise, and twiddle factor approximation. The size of phase error caused by the finite wordlength implementation of DFT twiddle factors is shown significantly lower than that of magnitude error. The drastic reduction of the phase error is achieved by the exploitation of the quadruplet symmetry characteristics of the approximated twiddle factors in the complex plane. Four channel power-line phase measurement system is also designed and implemented based on the time-multiplexed sharing architecture of the proposed algorithm. The operation of the developed system is also verified by the experiment performed under the test environment implemented with the multi-channel function generator and the on-line interfaced host processor system. The proposed algorithm's features of phase measurement accuracy and its robustness against the finite wordlength effects can provide a significant impact especially for the ASIC or microprocessor based embedded system applications where the enhanced processing speed and implementation simplicity are crucial design considerations.

  • PDF

A Study on the Autogenous Shrinkage Control of Ultra.High. Strength Concrete -Focused on physical properties and length variation- (초고강도 콘크리트의 자기수축제어에 관한 연구 -물리적 특성과 길이변화율을 중심으로-)

  • Park, Hyun;Han, Da-Hee;Cho, Seung-Ho;Kim, KWang-Ki;Kim, Woo-Jae;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.653-656
    • /
    • 2008
  • As super.high.strength concrete uses a large amount of binder, there is an autogenous shrinkage strain larger than dry shrinkage and it degrades the quality of structures. Thus, we need a technology to minimize the shrinkage strain of super.high.strength concrete. Accordingly, the present study prepared super.high strength concrete with design strength of over 80MPa and, using an embedded gauge, measured the shrinkage strain of free shrinkage specimens for super.high.strength concrete containing expansion agent. According to the results of this study, the expansion rate of concrete increased in the early stage due to the admixture of expansion agent, but the shrinkage rate went down with the lapse of time. The effect of the admixture of expansion agent on compressive strength appeared insignificant. Further research shall be made on different kinds of expansion agents and various mixture ratios for basic analysis to reduce autogenous shrinkage of super.high.strength concrete.

  • PDF

The effect of bonded resin surface area on the detachment force of lingual bonded fixed retainers: An in vitro study

  • Lee, Il-Hong;Lee, Jung-Hwan;Park, In-Young;Kim, Ji-Hyun;Ahn, Jang-Hoon
    • The korean journal of orthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • Objective: The aims of this study were to evaluate the relationship between the detachment force and bonding resin surface are and to determine the resin bonding surface area that would provide adequate bonding strength with minimum resin volume. Methods: One hundred and sixty human premolars were randomly divided into 4 groups of 40 teeth each. The diameter of the resin surface area in each group was as follows: group 1, 1.5 mm; group 2, 2.5 mm; group 3, 3.5 mm; and group 4, 4.5 mm. Respond Dead Soft straight (length 0.0175 inch) was used to fabricate the retainers, and $Transbond^{TM}$ XT was used to fix the retainers to the tooth surfaces. A pair of teeth was embedded in acrylic blocks for each specimen. Thus, each group comprised 20 samples. Fixed retainers were bonded to the teeth, and vertical force was applied at the middle of wire. The force was measured using a universal testing machine. Results: The mean value of detachment force was the highest for group 4 ($102.38{\pm}2.92N$), followed by group 3 ($63.54{\pm}2.21N$), group 2 ($51.95{\pm}1.61N$), and group 1 ($24.14{\pm}1.38N$). Conclusions: The detachment force of lingual fixed retainers was significantly affected as the area of the resin bonding surface increased. Considering the minimum bonding strength of brackets, a resin bonding surface area with a diameter of 3.5 mm would provide adequate bonding strength.

Design of a High-Performance Information Security System-On-a-Chip using Software/Hardware Optimized Elliptic Curve Finite Field Computational Algorithms (소프트웨어/하드웨어 최적화된 타원곡선 유한체 연산 알고리즘의 개발과 이를 이용한 고성능 정보보호 SoC 설계)

  • Moon, San-Gook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.293-298
    • /
    • 2009
  • In this contribution, a 193-bit elliptic curve cryptography coprocessor was implemented on an FPGA board. Optimized algorithms and numerical expressions which had been verified through C program simulation, should be analyzed again with HDL (hardware description language) such as Verilog, so that the verified ones could be modified to be applied directly to hardware implementation. The reason is that the characteristics of C programming language design is intrinsically different from the hardware design structure. The hardware IP which was double-checked in view of hardware structure together with algoritunic verification, was implemented on the Altera CycloneII FPGA device equipped with ARM9 microprocessor core, to a real chip prototype, using Altera embedded system development tool kit. The implemented finite field calculation IPs can be used as library modules as Elliptic Curve Cryptography finite field operations which has more than 193 bit key length.

Clonorchis sinensis: Analysis of the Characterization of Somatic and Metabolic Antigens (1) Immunohistochemical Characteristics of the Spleen in Mice When Intraperitoneally Injected with Antigens (간흡충: 충체 및 대사성 항원의 특성분석 (1) 항원투여 마우스 비장조직에 대한 면역조직화학적 연구)

  • 양용석;류장근;주난영;송강원
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.275-282
    • /
    • 1996
  • The authors inquired into what reactions comprise the response of mice(as a model) CD3, CD4 and CD8 monoclonal antibodies in spleen tissue when injected intraperitoneally by antigens of Clonorchis sinensis. The author is objective was focused on investigating the property of cellular immunity for liver fluke. In particular, the results of having examined the phenotype of the tissue of spleen were revealed as follows: a certain length of time after having been intraperitoneally injected with antigens of Clonorchis sinensis and Freund's adjuvant, the tissue of spleen was embedded and immunohistochemically stained by the avidin-biotin complex method. A strong reaction in response to CD3, while a feeble reaction resulted from CD4 and CD8. The tissue region showed a positive reaction to all antibodies, especially from capsules, vascular areas, white pulps and membrane of blood cells.

  • PDF