• Title/Summary/Keyword: Embedded data

Search Result 2,138, Processing Time 0.024 seconds

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel. undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesio-distally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference on fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even of that portion consists of mainly enamel and a little dentin structure.

  • PDF

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.

Identification of Tumor Suppressor Loci on the Short Arm of Chromosome 16 in Primary Small Cell Lung Cancers (원발성 소세포폐암에서 염색체 16번의 단완에 위치한 종양억제유전자좌의 확인)

  • Kee, Hyun Jung;Shin, Ju Hye;Chang, Joon;Chung, Kyung Young;Shin, Dong Hwan;Kim, Young Sam;Chang, Yoon Soo;Kim, Sung Kyu;Kwak, Seung Min;Kim, Se kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.597-611
    • /
    • 2003
  • Background : Loss of the short arm of chromosome 16 is a frequent event in various cancers, which suggests the presence of tumor suppressor gene(s) there. To map precise tumor suppressor loci on the chromosome arm for further positional cloning efforts, we tested 23 primary small cell lung cancers. Method : The DNAs extracted from paraffin embedded tissue blocks with primary tumor and corresponding control tissue were investigated. Twenty polymorphic microsatellite markers located in the short arm of chromosome 16 were used in the microsatellite analysis. Results : We found that six (26.1%) of 23 tumors exhibited LOH in at least one of tested microsatellite markers. Two (8.7%) of 6 tumors exhibiting LOH lost a larger area in chromosome 16p. LOH was observed in five common deleted regions at 16p. Among those areas, LOH between D16S668 and D16S749 was most frequent (21.1%). LOH was also observed at four other regions, between D16S3024 and D16S748, D16S405, D16S420, and D16S753. Six of 23 tumors exhibited shifted bands in at least one of the tested microsatellite markers. Shifted bands occurred in 3.3% (15 of 460) of the loci tested. Conclusion : Our data demonstrated that at least five tumor suppressor loci might exist in the short arm of chromosome 16 and that they may play an important role in small cell lung cancer tumorigenesis.

Studies on the postnatal development of the Leydig cell in rabbits (토끼에서 출생 후 고환간질세포의 발생에 관한 연구)

  • Tae, Hyun-Jin;Park, Young-Jae;Kang, Hyung-Sub;Kim, Nam-Soo;Park, Sang-Youel;Yang, Hong-Hyun;Ahn, Dong-Choon;Kim, In-Shik
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.3
    • /
    • pp.325-334
    • /
    • 2005
  • Changes in the rabbit Leydig cell from birth to adulthood were studied in New Zealand white rabbits of 1, 7, 21, 35, 49, 70, 105, 147, 196, and 252 days (n = 8 rabbits per group) of age. The objectives of this study were to understand the fate of the fetal Leydig cells, to determine the changes in serum testosterone levels, and leutenizing hormone-stimulated testosterone production per testis in vitro, and to quantify adult Leydig cells by number and average volume with age. Testes of rabbits were fixed by whole body perfusion using a fixative containing 2.5% glutaraldehyde in cacodylate buffer, processed and embedded in Epon-araldite. Using $1{\mu}m$ sections stained with methylene blue-azure II, qualitative and quantitative (stereological) morphological studies were performed. Testosterone levels in the incubation medium of luteinizing hormone-stimulated (100 ng/ml) testosterone secretion per testis in vitro, and in serum were determined by radioimmunoassay. The average volume of a testis of 1-day-old rabbits was determined as $0.0073cm^3$ and the parameter increased linearly from birth to 252 days ($3.93cm^3$). The volume density of the seminiferous tubules increased with age from 33.76% at day 1 to 88.2% at day 252. The volume density of the interstitium represents 66.24% of the testicular parenchyma at day 1. This proportion progressively diminished during development to reach a value of 11.8% at day 252. The volume density of Leydig cells increased almost linearly from birth (0.001%) to 252 days (2.62%). Leydig cell mass per testis increases from 0.0012 mg to 0.25 mg between days 1 and 35, from 2.66 mg to 44.3 mg between days 49 and 105 and from 65.42 mg and 102.9 mg between days 147 and 252. The absolute numbers of adult Leydig cells per testis increased linearly from birth to 252 days. The average volume of adult Leydig cell on days 1, 7, 21 and 35 was not significantly different; a gradual and continued increase was observed thereafter, reaching a 3-fold increase at 196 and 252 days. Serum testosterone concentrations were not significantly different at day 1 compared days 7, 21, 35. Significant increases were observed at days 49 and 70. Values at days 70 and 105 and days 147, 196, and 252 were not significantly different. LH-stimulated testosterone production per testis in vitro was significantly different at day 1 compared days 7, 21, 35. Significant increases were observed at days 49 and 70. Hormonal values at days 105, 147, 196, and 252 were not significantly different. These data suggested Leydig cell developmental phase can be classified: a neonatal phase (1-7 days), a prepubertal phase (14-49 days) and an adult phase (70-252 days). Immature and mature adult Leydig cells, initially detected at days 7 and 49, respectively, and mature adult Leydig cells were abundant Leydig cell type according to the number and absolute volume per testis form day 49 onwards.

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel, undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesiodistally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference in fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even if that portion consists of mainly enamel and a little dentin structure.

Effect of location of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture (광중합형 레진에 함침시킨 유리섬유의 위치가 상악 총의치의 파절강도와 파절양상에 미치는 영향)

  • Yoo, Hyun-Sang;Sung, Su-Jin;Jo, Jae-Young;Lee, Do-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • Purpose: This study evaluated the effect of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture. Materials and methods: Maxillary acrylic resin complete dentures reinforced with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheongun, Korea) and without reinforcement were tested. The reinforcing material was embedded in the denture base resin and placed different regions (Control, without reinforcement; Group A, center of anterior ridge; Group B, rugae area; Group C, center of palate; Group D, full coverage of denture base). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The data were analyzed with one-way ANOVA at the significance level of 0.05. Results: There were non-significant differences (P>.05) in the fracture strength among test groups. Group A showed anteroposterior fracture and posterior fracture mainly, group B, C and control group showed partial fracture on center area mostly. Most specimen of group D showed posterior fracture. Conclusion: The location and presence of the fiber reinforcement did not affect the fracture strength of maxillary complete denture. However, reinforcing acrylic resin denture with glass fiber has a tendency to suppress the crack.

The Effect of Teacher Support Program for the Integration of Handicapped Children on Teaching Efficacy of Daycare Center Teachers (장애 유아 통합보육을 위한 교사 지원이 어린이집 교사의 교사 효능감에 미치는 영향)

  • Park, Na Ri
    • Korean Journal of Child Education & Care
    • /
    • v.18 no.4
    • /
    • pp.247-265
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effect of teacher support program for integration of handicapped children on teaching efficacy of daycare center teachers. Methods: In the study, 12 day care teachers in 4 day care centers in Seoul and Gyeonggi area were selected as experimental groups and 12 teachers in 5 day care centers were selected as control group. Teacher education is carried out through group education, such as understanding of developmental area, curriculum modification, activity-based embedded intervention, cooperative learning, direct teaching, disability understanding education, behavior support, family support. Individual teacher education provided counseling on the reality of child care for children with disabilities that reflects the needs of teachers for integrated child care for handicapped children. Teacher's Efficacy in Inclusive Practices (TEIP) was used as a pre post test to measure teacher's efficacy change. In order to analyze the results of the study, two independent sample t tests were conducted on the difference between pre-post test of teacher efficacy between the two groups. Results: As a result, There was a significant difference in the pre-post change of teacher efficacy between the two groups. Conclusion/Implications: The results of this study are as follows, teacher support program provided immediate feedback in integrated child daycare center for the handicapped children, child care teachers improved their integrated handicapped children care expertise, provided responsive teacher support program to the actual needs of the site, teacher support program reflected various variables related to integration, and emphasized the cooperative relationship between researcher and child daycare center teacher. The results of this study can be used as actual data of field where lack of support for the integration of handicapped children is lacking.

Evaluation of Patient Radiation Doses Using DAP Meter in Interventional Radiology Procedures (인터벤션 시술 시 면적선량계를 이용한 환자 방사선 선량 평가)

  • Kang, Byung-Sam;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipments in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effectives of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were $237.7Gy{\cdot}cm^2$ in TACE, $17.3Gy{\cdot}cm^2$ in AVF, $114.1Gy{\cdot}cm^2$ in LE PTA & STENT, $188.5Gy{\cdot}cm^2$ in TFCA, $383.5Gy{\cdot}cm^2$ in Aneurysm Coil, $64.6Gy{\cdot}cm^2$ in PTBD, $64.6Gy{\cdot}cm^2$ in Biliary Stent, $22.4Gy{\cdot}cm^2$ in PCN, $4.3Gy{\cdot}cm^2$ in Hickman, $2.8Gy{\cdot}cm^2$ in Chemo-port, $4.4Gy{\cdot}cm^2$ in Perm-Cather, $17.1Gy{\cdot}cm^2$ in PCD, and $357.9Gy{\cdot}cm^2$ in Vis, EMB. Dose referenece level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipments and procedures in the interventional radiology procedures, further studies and monitorings are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

A Study on the Documentation Related to Mugeuk-do: Focusing on Its Comparison and Historical Evidence (무극도 관련 문헌 연구 - 비교 및 고증을 중심으로 -)

  • Park Sang-kyu
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.41
    • /
    • pp.27-61
    • /
    • 2022
  • Documentation related to Mugeuk-do (Limitless Dao) is rare in comparison to other Korean new religions given that it has been open to the public and translated since the 1970s. Due to its rarity, the documentation has been used uncritically, without there being any comparative study or historical research. It is undeniable that distortions and fallacies are embedded in these documents, and this has resulted in quite a few problems in precisely understanding Mugeuk-do and Daesoon Jinrihoe (The Fellowship of Daesoon Truth), an order that has inherited the legacy of Mugeuk-do. In this regard, this study aims to critically define the characteristics and limitations of the major documents related to Mugeuk-do that were published by the colonial government in the 1920s~1930s and recorded by multiple orders in the 1970s-1980s through comparisons. An attempt to conduct this research allows for the discovery of a solution to the problem of uncritical usage of those materials. The documents produced by the colonial government that can be used as basic texts to study Mugeuk-do are The General Conditions of the Religion Mugeuk-do (無極大道敎槪況) and Unofficial Religions of the Korea (朝鮮の類似宗敎). These can be found through bibliography, comparison, and historical research. Chapters 6, 7, and 8 of The General Conditions of the Religion Mugeuk-do are a possible source on the order that reflects the circumstances of Mugeuk-do until 1925. In the case of Unofficial Religions of the Korea, if the descriptive perspective on unofficial religions is excluded, the articles written about the circumstances post 1925 have credibility. Another document that describes multiple orders and can be used as a basic text is chapter 2 of 'Progress of the Order' in Daesoon Jinrihoe's The Canonical Scripture. This is because its record precisely reflects the conditions of the era, with regard to the fact that it is the freest from distortions caused by changes in the belief system and it is less biased towards certain sects or denominations. Furthermore, the collection period of the articles is the earliest. Accordingly, as basic texts, Chapters 6, 7, and 8 of The General Conditions of the Religion Mugeuk-do and the articles from Unofficial Religions of the Korea after 1925, as well as chapter 2 of 'Progress of the Order' in The Canonical Scripture are appropriate for studying Mugeuk-do. In addition, Overview of Bocheonism, History of Jeungsan-gyo, and The True Scripture of the Great Ultimate can be utilized as references after removing distortions and fallacies through comparative study. Henceforth, relevant documents should be utilized to establish comprehensive data on Mugeuk-do through comparative and historical research.