• Title/Summary/Keyword: Embedded data

Search Result 2,135, Processing Time 0.034 seconds

Effect of Provisional Restorative and Filling Materials on Bond Strength of Adhesive Resin Cement between Lithium Disilicate Glass-Ceramic and Dentin (Lithium Disilicate Glass-ceramic과 상아질 간의 접착성 레진 시멘트의 결합강도에 대한 임시 수복재와 임시 충전재의 영향)

  • Oh, Sang-Chun;Sim, Hun-Bo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.359-365
    • /
    • 2013
  • The aim of this study was to evaluate the effect of temporary restorative and filling material on bonding strength between lithium disilicate glass-ceramic and dentin. 60 extracted human molars were cross-sectioned at occlusal third and were embedded into self-cure acrylic resin. Then the teeth were randomly divided into four groups of 15 each. Lithium disilicate glass-ceramic is cemented to dentin as follows: after no any application of the provisional materials (Group A), after application of ALIKETM (GC America Inc.)(Group B), after application of Luxatemp$^{(R)}$ Automix plus (DMG, Germany)(Group C), after application of Fermit$^{(R)}$ (Ivoclar Vivadent, Leichtenstein)(Group D). After the specimens were stored in distilled water for 24 hours, the shear bond strength of the specimens were measured using UTM (Zwick 1456 41, Zwick, Germany) at a crosshead speed of 1mm/min. The data were analysed by one-way ANOVA and Tukey HSD tests. There were no statistically significant differences of bond strength among the groups. Fracture type was showed mixed type of adhesive and cohesive fracture in most of specimens. Within the limitation of this study, bond strength of adhesive resin cement between lithium disilicate glass-ceramic and dentin was not affected by provisional restorative and filling materials.

A study of Tumor Angiogenesis in Human Lung Cancer by Immunohistochemical Stain (Human Lung Cancer에서 면역세포화학적 방법을 이용한 Tumor Angiogenesis에 관한 연구)

  • Cheon, Seon Hee;Kim, Sung Sook;Rha, Sun Young;Chung, Hyun Cheol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.894-902
    • /
    • 1996
  • Background : Tumor angiogenesis is the growth of new vessels toward and within tumor. It has been demonstrated that the growth of tumor beyond a certain size requires angiogenesis and it is closely involved in tumor progression and metastasis. The finding that intensity of neovascularization correlates independently with metastasis may lead to identification of patients in whom radical surgery should be supplemented by systemic treatment. Method : We have collected paraffin blocks of bronchoscopic biopsy of patients with non-small cell lung cancer. We highlighted the vessel by staining endothelial cell with JC70 monoclonal antibody(to CD31) immunohistochemically and counted microvessels under 200 X field using light microscopy. Results : 1) The mean microvessel count was $32.7{\pm}20.8$ (9-96) in total 29 cases. 2) There were no correlations between microvessel counts and pathologic cell type, T staging, node melastasis(N) and hematogenous metastasis(M) (p>0.05). 3) The median follow-up duration was 15 months(2-46) and there was no correlation between the microvessel counts and survival rate of lung cancer patients (p>0.05). Conclusion : Tumor angiogenesis seems to be an important prognostic factor suggesting the probability of metastasis. But the microvessel count in the bronchoscopic biopsy specimen was inadequate and very limited. There has been no data about angiogenesis of lung cancer in korea yet So the study of tumor angiogenesis using resected lung tumor specimen would be demanded.

  • PDF

Recognition and Performance of Patient Private Information Protection (PPIP) in Nursing Students (환자 개인정보보호에 대한 간호대학생의 인식과 실천)

  • Kim, Chang-Hee;Jeong, Sun-Young;Song, Yong-Shin
    • Journal of Digital Convergence
    • /
    • v.11 no.11
    • /
    • pp.479-490
    • /
    • 2013
  • In this research we surveyed level of textual recognition and of practice by nursing students regarding patient privacy protection. The subjects were 383 nursing students. The questionnaire developed by Lee and Park (2005) were modified and used. Data analysis was conducted through descriptive statistics, t-test, ANOVA, and Pearson correlation coefficients. The result shows that about 96.1% of the subjects received education on patient privacy protection in school or hospital but 48.0% of all received education of 10 minutes or less. Average score for recognition of patient privacy protection was a 4.13 but average practice score was 3.84. Among all areas, communication tasks showed the highest scores for both recognition and practice. There are differences according to grade in school and age of the subject, and experience with clinical practice, existence of regular educational program embedded in clinical practice at hospitals, and the length of each educational session. For both total score and score for every domain, there was a correlation between recognition and practice. The conclusions drawn from this research will help colleges of nursing and hospitals to design and develop contents of educational programs for nursing students.

Site Monitoring of Crews and Passengers on Board by the BLE and PLM Combination (BLE와 PLM 조합의 승선자 위치 모니터링)

  • Kwon, Hyuk-Joo;Yang, Hyun-Suk;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.463-467
    • /
    • 2015
  • When unforeseen accidents occur in a ship, it is important to save passengers safely and remove them from the accident area quickly. To solve such a situation, site information of passengers on board always must be identified. This paper implemented a site monitoring of crews and passengers based on the BLE and PLM combination, to prepare for unexpected accidents of the ships. This system was composed of BLE tag for crews, passengers and each room, PLM networks, data server, and monitoring PC. In this system, site information derived from the tag attached to the bodies and cabins of crews and passengers are transmitted through a power line network, and monitored on the screen of a monitoring PC. The proposed system guides them into the only authorized area considering the ship security and passengers' safety, and even has a special alarm call to warn them after entering an unauthorized area. This system enables the BLE-embedded tag battery to use for a long time because the BLE consumes low electric power, and can gain an economic advantage.

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Spatial Characters of Workplace and Everyday Life of Immigrant Workers in S. Korea (한국 이주노동자의 일터와 일상생활의 공간적 특성)

  • Choi, Byung-Doo
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.319-343
    • /
    • 2009
  • This paper considers some kinds of socio-spatial constraints and strategies for overcoming them which immigrant workers in Korea have experienced in their work-place and life-space, with an analysis of questionnaire data and of direct interview materials on them. Though they appear somewhat satisfactory or positive with their work-place, this can be seen as a hypocritical or false attitude rather than a real one: they are forced to work with long hours (more than 70 hours per week) and rigid controls in the other' territory. Their daily life-spaces also are severe: they can be hardly embedded in an existing community with a sense of place due to serious institutional and interaction constraints, even though they seem to have a basic mobility to survive in life-spaces. In order to escape or alleviate such local constraints, they try to constitute multi-scalar (local, trans-regional, and transnational) networks, and to find informations and means to resolve or cope with them. However, this kind of endeavors of immigrant workers to make a trans-national network and social space has a limitation for them to be free entirely from constraints, which might be strengthened with a lack of geographical knowledge of them. Then immigrant workers in Korea live ineluctably with not only hybrid national identity but also with disturbed local identity in an aliened workplace and life-spaces.

  • PDF

Design of an $SpO_2$ Transmission Agent based on ISO/IEEE 11073 Standard Protocol (ISO/IEEE 11073 표준 프로토콜 기반의 산소포화도 전송 에이전트 설계)

  • Pak, Ju-Geon;Im, Sung-Hyun;Park, Kee-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.462-465
    • /
    • 2011
  • A pulse oximeter is a device which provides non-invasive estimate of percentage oxygen saturation of haemoglobin (SpO2). Due to the limitations of resources of personal health devices (PHDs) including pulse oximeters, they generally transmit the estimated data to a remote monitoring server through a close manager (e.g. mobile device or PC). Therefore, communication protocols between PHDs and a manager is an important research topic in terms of interoperability. In this paper, we present design results of an SpO2 transmission agent based on the ISO/IEEE 11073 (X73) protocol. The protocol is an international standard for PHDs. The agent is an embedded program which generates X73 messages from the estimated pulse rates and SpO2, and transmits the messages to a close manager. The agent consists of a Session, Message and Memory Handler. The Session Handler manages a communication session with the manager, and the Message Handler generates and analyzes the exchanged messages according to the X73 protocol. The Memory Handler extracts pulse rates and SpO2s which are stored in a memory of the pulse oximeter. The SpO2 transmission agent allows pulse oximeters to communicate with managers based on x73 standard. Consequently, the interoperability between the pulse oximeters and the managers is guaranteed.

  • PDF

THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION (응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

Remote Access and Data Acquisition System for High Voltage Electron Microscopy (초고전압 투과전자현미경의 원격제어 및 데이터 획득 시스템)

  • Ahn, Young-Heon;Kang, Ji-Seoun;Jung, Hyun-Joon;Kim, Hyeong-Seog;Jung, Hyung-Soo;Han, Hyuck;Jeong, Jong-Man;Gu, Jung-Eok;Lee, Sang-Dong;Lee, Jy-Soo;Cho, Kum-Won;Kim, Youn-Joong;Yeom, Heon-Young
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • A new remote access system for a 1.3 MV high voltage electron microscope has been developed. Almost all essential functions for HVEM operation, huck as stage control, specimen tilting, TV camera selection and image recording, are successfully embedded into this prototype of the remote system. Particularly, this system permits perfect and precise operation of the goniometer and also controls the high resolution digital camera via simple Web browsers. Transmission of control signals and communication with the microscope is accomplished via the global ring network for advanced applications development (GLORIAD). This fact makes it possible to realize virtual laboratory to carry out practical national and international HVEM collaboration by using the present system

Design and Implementation of Location Based Seamless Handover for IEEE 802.11s Wireless Mesh Networks (IEEE 802.11s 무선 메쉬 네트워크를 위한 위치 기반 핸드오버의 설계 및 구현)

  • Lee, Sung-Han;Yang, Seung-Chur;Kim, Jong-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.10
    • /
    • pp.2004-2010
    • /
    • 2009
  • The characteristic of the backbond for distribution service in WMNs(Wireless Mesh Networks) is that WMNs has multiple links connected to mesh points and dynamic routing protocol such as AODV to establish routing paths. When the terminal is communicating with the service through new AP, mobile nodes can resume communication by setting only the link between new AP and mobile node in the case of existing WLANs, but WMNs needs path establishment process in multihop networks. Our goal in this paper is to support the seamless communication service by eliminating path establishment delay in WMNs. We present the method that eliminates the handover latency by predicting the location of handover using GPS information and making the paths to their destination in advance. We implement mesh nodes using embedded board that contains proposed handover method and evaluate performance of handover latency. Our experiment shows that handover delay time is decreased from 2.47 to 0.05 seconds and data loss rate is decreased from 20~35% in the existing method to 0~10% level.