• Title/Summary/Keyword: Elevator safety

Search Result 141, Processing Time 0.029 seconds

A Study on Design Improvement for Smoke-Control System Using the Pressurization of the Elevator Shaft (승강로 가압 제연설비의 설계개선에 관한 연구)

  • Kim, Il-Young;Kim, Kyung-Jin;Hong, Ji-Hwan;Kwon, Chang-Hee;Yoo, Chul-Kwon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.74-83
    • /
    • 2019
  • In the U.S., the pressurization of elevator shaft was developed in 1972 to allow vulnerable people, such as the elderly and weak who could not use escape stairs in case of fire, to evacuate. It is an advantage in terms of space saving by not using vertical ducts. This study drew the problem of the pressurization of elevator shaft based on the existing domestic patents and proposed improvements. The smoke control volume calculation method is proposed by using vertical modeling. Leakage gaps in elevator doors need to be reviewed through experimental data or actual data. The evacuation floor was divided, the openings in the elevator machine room were automatically closed to the fire signal and the relief damper was installed to improve the performance. The improved method functions as the smoke control damper supplying the air flow rather than maintaining the differential pressure. To increase reliability of the research results, the procedure was performed to verify by using Contam.

Improvement of Elevator Management System after Completion (준공 이후 승강기 관리체계 개선에 관한 연구)

  • Cho, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.455-461
    • /
    • 2016
  • To operate a large structure or a high-rise building, elevator is essential. Nevertheless, elevator breakdowns or accidents have been consistently reported. When the accidents are not serious, the records are not reported and cumulated in the Korea Elevator Safety Agency. Additionally, in case of replacement or repair of the parts of elevator, conflicts about the person responsible for the expense of the replacement or repair are frequently occurred. However the record of accidents is not decreasing and the conflict about the fund of elevator repair is serious. So, it is needed to reduce the elevator accidents or malfunction, the operation stop of the elevator, the conflict between building owners and users. Therefore, in this study, the elevator maintenance procedures during defect liability period, the notification procedure in case of breakdown or accident elevator, the direction of elevator maintenance contracts, the direction of the elevator inspection were suggested.

Case Study of the Field-BIM for Precision Construction of Elevator Core Wall in Top-down Project (Top-down 공법 현장에서 엘리베이터 코어월 정밀 시공을 위한 시공 BIM의 적용 사례 연구)

  • Shim, Hak-Bo;Seok, Won-Kyun;Park, Soon-Jeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.108-109
    • /
    • 2019
  • Top-down construction is a useful method of utilizing the working space, economic benefits and shorten the construction period. Precision construction of the elevator core is very important for safety of the top-down structure. In this study, the layout system for the field-BIM(Building Information Modeling) was used to precisely construct the elevator core in the basement and the ground. Through the layout system, it was possible to process the construction status, review the design results and construction errors, and confirm whether there is or not within the construction error range for elevator installation.

  • PDF

Research of Circuit Working Construction Elevator with Single-guide Rail and Multi-cages

  • Kun Zhang;Kaiqiang Wang;Di Li;Qing Sun;Zhen Ye;Wei Liu
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.2
    • /
    • pp.137-144
    • /
    • 2022
  • As one of the most important vertical transportation equipment in super high-rise buildings, the construction elevator directly affects the project period, cost, and effectiveness. The paper proposes a new construction elevator with single-guide rail and multi-cages. It can solve the problems of single construction elevator capacity shortage and efficacy decrease with height reduction, the occupancy of plan and elevation position of multiple construction elevators, and extension of total construction period by cycling operation of multi-cages on a single-guide rail. The paper focuses on the design and research of the main components of the equipment, such as the rotating guide rail mechanism, vertical bearing mast tie system, segmented electrical power supply system, group control scheduling system, and safety anti-collision system.

Measures and Cause Analysis of Electrical Disturbance for Elevator Equipment of the Apartment House (공동주택 승강기 설비의 전기적 장해 원인 분석 및 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Park, Chee-Hyun;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.88-95
    • /
    • 2007
  • Domestic elevator accidents which are related to human life such as death are occurring steadily. This research measured and analyzed for the quality of power source which has possibility to be associated with fault and malfunction of elevator equipment although it is not direct cause examination. In conclusion, we acquired the result that there is possibility that the quality of power source(Sag, Interruption, Harmonic, Electromagnetism emission waveform, Static electricity etc) has an effect on movement of elevator through examination of three elevator facility models and suggested measures for it. Accordingly, this research result will be used as data to suggest establishment of elevator examination regulations and KS regulations for domestic elevator industry and the least safety of household using elevator.

A Study on the Estimation for the Flow Coefficient of Elevator Shaft (엘리베이터 샤프트의 유량계수 산정에 관한 연구)

  • Kim, Hak-Joong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.148-157
    • /
    • 2012
  • Recently, evacuation safety of building residents becomes the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is being progressed. Elevator shaft flow coefficient is the major factor for the calculation of elevator piston effect. The results of this study can be used for the study of elevator piston effect as basic data. The flow coefficient simulation was performed using FLUENT, commercial CFD program. As a result of the flow coefficient simulation, the coefficient is 0.88 considering the safety factor. This result is verified that the result of experimental study, 0.86 is conservative.

The Design of Elevator Safety Management Service System based on Data Minining (데이터마이닝 기반 승강기 안전 관리 서비스 시스템 설계)

  • Kim, Woon-Yong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.83-90
    • /
    • 2010
  • The demands of analysis for the physical errors of systems and prediction system using this has increased steadily with computing environment growth linking real system just like IT Convergence. The physical errors are unpredictable because of relations of various elements such as natural phenomenon and mechanical errors. Especially, the elevator system occurs various problems because of the complexity of system so that we need to efficient approach for this. In this paper, we propose the analysis and management system for elevator based on data minining that predict the error to gather information about physical or natural phenomenon. This helps actively responding in early stage and saving lives through prediction of error and an early warning for just such an eventuality.

  • PDF

FEM Analysis of a 38 Person Elevator Brake (38인승 승강기 제동장치의 유한요소해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6458-6463
    • /
    • 2014
  • This study performed FEM analysis of a 38 person elevator brake. Recently, an emergency brake was newly developed to improve elevator safety. A 3D design was developed using Solid Works and FEM analysis using analysis code ANSYS. The total deformation, stress and strain were obtained.

Useful Lifetime Evaluation of Rubber Component for Elevator Cabin (승강기용 방진고무부품 특성 및 사용수명 평가)

  • Woo, Chang-Su;Park, Hyun-Sung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.576-580
    • /
    • 2008
  • Rubber material properties and useful life evaluation are very important in design procedure to assure the safety and reliability of the rubber components. In this paper, the evaluation of characteristics and useful life prediction of rubber component for elevator cabin were experimentally investigated. The material test and accelerated heat-aging test were carried. Rubber material constants were obtained by curve fittings of simple tension, pure shear and bi-axial tension test data. Heat aging test results changes as the threshold are used for assessment of the useful life and time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. By using the rubber material and component test several useful life prediction equations for rubber component were proposed. Predicted useful life of rubber component for elevator cabin agreed fairly with the experimental lives.

  • PDF