• 제목/요약/키워드: Elevator lobby

검색결과 13건 처리시간 0.024초

엘리베이터 실내공기질의 특성 기초조사 (A Study on the Characteristics of Indoor Air Quality in Elevator)

  • 박정호;추연규;서정민
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.677-685
    • /
    • 2012
  • The elevator is needed healthy and comfortable indoor air quality (IAQ) for using many people, but we found nothing about IAQ studies of an elevator. In general, air in the elevator car is sucked from the elevator's hoistway straight into the car using a fan. The air sucked into the hoistway may be filled with dust, mold and bacteria. This study was performed to measure of characteristics of indoor air quality (PM10, falling bacteria, $CO_2$, Rn and HCHO) in elevator's hoistway, CAR and lobby of 8 sites (4 apartments and 4 commercial buildings) in Gyeongnam from May, 2010 to January, 2011. With regards to the differences of pollutant distribution among hoistway, CAR, and lobby, the concentration of Rn and HCHO were the highest in hoistway followed by CAR and lobby, and PM10, falling bacteria and $CO_2$ were the highest in CAR followed by hoistway and lobby. Mean concentrations of PM10 were 104.9 ${\mu}g/m^3$ in CAR, 92.3 ${\mu}g/m^3$ in hoistway and 68.2 ${\mu}g/m^3$ in lobby, respectively.

피난 시나리오에 따른 승강장 부속실 차압 특성 연구 (Pressure Differentials in the Elevator Lobby Depending on the Evacuation Scenarios)

  • 박용환
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.38-43
    • /
    • 2007
  • 최근 우리나라 고층아파트에서 많은 문제가 되고 있는 승강장 부속실의 급기가압 시스템에 있어서 거주자의 피난 시나리오에 따른 차압의 변화 및 연기유동 특성을 FDS 화재모델링을 이용하여 현상학적으로 살펴보았다. 자동차압조절댐퍼의 기준압을 화재실로 할 경우 현관문 누설틈새를 통한 공기의 화재실 유입으로 화재실 및 부속실 모두 절대압이 크게 상승하는 결과를 가져왔으며 피난으로 계단실 방화문이 개방 후에는 다시 닫히지 않아 부속실내의 차압형성이 안 되는 문제점이 예상되었다. 따라서 화재실압이 지속적으로 상승하지 않도록 거실에 별도의 개구부가 필요한 것으로 판단된다. 현관문 개방 후 다시 닫힐 시에는 순간적으로 200 Pa 정도의 높은 과압이 형성되어 이 시간 동안에는 화재실 안의 또 다른 거주자가 현관문을 개방하기는 어려울 것으로 예상되었으며, 현관문만 개방 시에는 적정방연풍속이 유지되었으나, 현관문과 계단실 방화문이 동시에 개방되어 있을 경우에는 적정방연풍속이 생성되지 않아 부속실 및 계단실로의 연기유입이 발생하는 것으로 예측되었다.

급기가압 댐퍼의 설정 기준압에 따른 부속실 차압 특성 연구 (Pressure Differentials in the Elevator Lobby Depending on the Reference Pressures of the Pressurizing Dampers)

  • 박용환
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.12-17
    • /
    • 2007
  • 본 연구는 최근 우리나라 고층아파트에서 많은 문제가 되고 있는 승강장 부속실의 급기가압 시스템에 있어서 댐퍼 적정차압의 기준 압력에 대한 문제를 FDS 화재모델링을 이용하여 현상학적으로 살펴보았다. 화재 초기 누설틈새만 있는 밀폐된 화재실의 온도와 압력은 연소에너지와 고온 연소가스의 발생으로 온도와 압력이 크게 상승하는 것으로 나타났다. 따라서 자동차압조절 급기댐퍼의 기준압을 옥내 대기압으로 설정 시에는 화재 시 실제 차압의 감소와 방연풍속 부족으로 상황에 따라 피난안전 공간인 부속실로의 연기 유입이 발생할 우려가 있는 것으로 나타났다.

부속실 급기가압 시 압력특성 변화에 관한 연구 (A Study on the Pressure Change during the Pressurization to the Elevator Lobby)

  • 김범규;박용환;김홍식
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.99-104
    • /
    • 2012
  • 본 연구에서는 공동주택 화재 시 피난시나리오 및 화재실 배연개구부 유무에 따른 부속실 급기가압 시스템의 성능 및 효용성을 평가하기 위해 각 실의 압력변화 특성을 실험적으로 측정하였다. 그 결과, 화재실문과 계단실문 개폐 시나리오 및 배연개구부의 유무에 따라 압력변화 특성이 크게 달라졌으며 최저설계차압으로 재안정화 되기 전에 부속실 과압 또는 부압 발생, 도어클로져 닫힘 기능 저하 등의 현상이 나타났다. 또한. 급기댐퍼의 설치위치보다는 화재실 배연개구부의 존재가 규정방연풍속 유지에 필수적인 것으로 나타났다.

Elevator Pressurization in Tall Buildings

  • Klote, John H.
    • 국제초고층학회논문집
    • /
    • 제2권4호
    • /
    • pp.341-344
    • /
    • 2013
  • During a building fire, smoke can flow through elevator shafts threatening life on floors remote from the fire. Many buildings have pressurized elevators intended to prevent such smoke flow. The computer program, CONTAM, can be used to analyze the performance of pressurization smoke control systems. The design of pressurized elevators can be challenging for the following reasons: (1) often the building envelope is not capable of effectively handling the large airflow resulting from elevator pressurization, (2) open elevator doors on the ground floor tend to increase the flow from the elevator shaft at the ground floor, and (3) open exterior doors on the ground floor can cause excessive pressure differences across the elevator shaft at the ground floor. To meet these challenges, the following systems have been developed: (1) exterior vent (EV) system, (2) floor exhaust (FE) system, and ground floor lobby (GFL) system.

학교건축의 복도(複道) 계획에 관한 연구 (A Study on the Architectural Design of Student Circulation Space)

  • 이화룡
    • 교육녹색환경연구
    • /
    • 제3권1호
    • /
    • pp.24-34
    • /
    • 2003
  • The architectural design of student circulation space has a pronounced influence on the educational function of a school building. Recent curriculum and new teaching methods have required the sufficient space provided for circulation and various circulation spaces in a school building, such as elevator, pilotis, bridge, atrium, deck, lobby and locker room. However excessive circulation space is wasteful form the standpoint of both initial investment and operation. This study aims to investigate new circulation patterns and functions, and to propose the adequate size in planning a school corridor. For this purpose, it explores the recent trends of the corridor planning represented in the excellent school facilities in 2002. and analyzes the newly-added functions In the school corridor : architectural in-between space, dwelling space for ordinary activities, space for educational media and auxiliary learning space. This research recommends that the corridor width be carefully planned according to the supposed functions in order to achieve the efficiency in the design of school facilities.

  • PDF

부속실 급기가압제연시 차압변화에 관한 실험적 연구 (An Experimental Study on the Pressure Differentials during the Pressurized Air Supply to the Elevator Lobby)

  • 김범규;박용환;김홍식
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.110-119
    • /
    • 2009
  • A fire should be accompanied by the heat and smoke. However, smoke is considered main cause of heavy casualties. Smoke easily spreads away from the fire area to remote space and cause mortal wound for the resident. A technical way effectively protecting the life and property from the smoke is the smoke control system of the building. Pressurized air supply system can be considered to prevent the refuge area from the smoke infiltration that evacuate residents via evacuation route for life safety. This paper is related with performance estimation and the effectiveness of the pressurized air supply system through experiments.

  • PDF

Preference for Spatial Planning Elements of Common Spaces in Senior Congregate Housing according to Pre-Senior Citizens

  • Hong Yi-Kyung;Oh Hye-Kyung
    • International Journal of Human Ecology
    • /
    • 제6권2호
    • /
    • pp.85-94
    • /
    • 2005
  • The purpose of this study is to analyze the preference of spatial elements for common space planning in senior congregate housing. For the study, 500 potential consumer's residing in Seoul was surveyed using the questionnaire in the social survey methodology. As for the common spaces, gardens, treatment, and exercise rooms were preferred. A combination of both separate and group arrangement of the buildings was preferred, indicating that people wanted separation of the common space and the individual living units. Second, people preferred sharing parts of the common space with their neighbors and as is the traditional custom, preferred to take off their shoes at the entrance to individual units. Third, for the furniture and facilities, they wanted the manager room in the lobby, the small meeting rooms in the public dining room, a fitness center in the activity room, the rack or alcove to store items in front of an individuals unit in the hallway, a chair to sit down in the elevator, and the chair to rest on the stairway landing. Fourth, in terms of priority for planning the senior citizens' community housing, safety, familiarity like a regular home, reduced isolation and loneliness, sense of belonging, economic factors, aesthetic appreciation, daily life supplement, variety, and self-identity were answered in that order.

실측과 시뮬레이션을 통한 초고층 주거건물에서의 연돌효과 문제의 해결 (Solving the Problems Caused by Stack Effect in a High-rise Residential Building through Field Measurement and Simulation; Case Study)

  • 구성한;조재훈;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제16권4호
    • /
    • pp.73-80
    • /
    • 2005
  • A high-rise residential building experienced stack effect problems during the winter such as difficulties in opening residential entrance doors and whistling noise from elevator doors generated by airflow. Field measurements were carried out on the building and the problems were verified by the analysis of the measurement results from three points of view: the total stack pressure difference, pressure distribution on each floor, and the location of the neutral pressure level. Based on the analysis of the three key parameters, possible solutions were proposed, such as zoning vertical shafts, lessening the airflow from the entrance doors on basement floors and lobby floor by installing vestibules, improving the airtightness of exterior walls, and installing separation doors where the problems occur. Simulations of proposed solutions were conducted and the effects of reducing the pressure difference were evaluated. Stack effect problems in a high-rise residential building were verified through field measurements and could be mitigated by the solutions which were drawn from the analysis of the field measurements and the simulation results.

노인주거환경 평가 틀에 관한 연구 (A Study on the Evaluation for Elderly Housing Environment)

  • 신화경;이준민
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년 춘계학술발표대회 논문집
    • /
    • pp.273-277
    • /
    • 2009
  • This study was conducted to develop standards for evaluating what extant the physical environments of housing which can cope with the needs of the aging society. This study was consisted through literature investigation research mainly, and research target literature limits keyword to elderly housing environment and chose connected domestic various literatures. The scope of evaluation was limited to the indoor spaces and outdoor spaces of housing as it was thought that the elderly spend much more time at indoor, outdoors, considering their physical characteristics. The study are as follows ; First, in outdoor only area from design environment element accessibility, and safety emphasized from equipment element, health of community territory was expose from design environment element that supportiveness is emphasized from equipment element. Second, in living room safety emphasized from design environment element in bedroom and bathroom of indoor individuation space, vestibule, balcony supportiveness, health was expose that is emphasized kitchen and mess. Also, was expose that supportiveness is emphasized from equipment element of all individuation spaces. Third, was expose that design environment element in corridor that is indoor official business space, stair, lobby, elevator and safety from equipment element and supportiveness are emphasized.

  • PDF