• Title/Summary/Keyword: Electrothermal

Search Result 78, Processing Time 0.023 seconds

The Analysis of Electrothermal Conductivity Characteristics for SOI(SOS) LIGBT with latch-up

  • Kim, Je-Yoon;Hong, Seung-Woo;Park, Sang-Won;Sung, Man-Young;Kang, Ey-Goo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.129-132
    • /
    • 2004
  • The electrothermal characteristics of a high voltage LIGBT(Lateral Insulated Gate Bipolar Transistor) using thin silicon on insulator (SOI) and silicon on sapphire (SOS) such as thermal conductivity and sink is analyzed by MEDICI. The device simulations demonstrate that the thermal conductivity of the buried oxide is an important parameter for modeling of the thermal behavior of SOI devices. In this paper we simulated the thermal conductivity and temperature distribution of a SOI LIGBT with an insulator layer of SiO$_2$ and $Al_2$O$_3$ at before and after latch-up and verified that the SOI LIGBT with the $Al_2$O$_3$ insulator had good thermal conductivity and reliability.

The thermal conductivity analysis of the SOI/SOS LIGBT structure (Latch up 전후의 SOI(SOS) LIGBT 구조에서의 열전도 특성 분석)

  • Kim, Je-Yoon;Kim, Jae-Wook;Sung, Man-Young
    • 한국컴퓨터산업교육학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.79-82
    • /
    • 2003
  • The electrothermal simulation of high voltage LIGBT(Lateral Insulated Gate Bipolar Transistor) in thin Silicon on insulator (SOI) and Silicon on sapphire (SOS) for thermal conductivity and sink is performed by means of MEDICI. The finite element simulations demonstrate that the thermal conductivity of the buried oxide is an important parameter for the modeling of the thermal behavior of silicon-on-insulator (SOI) devices. In this paper, using for SOI LIGBT, we simulated electrothermal for device that insulator layer with $SiO_2$ and $Al_2O_3$ at before and after latch up to measured the thermal conductivity and temperature distribution of whole device and verified that SOI LIGBT with $Al_2O_3$ insulator had good thermal conductivity and reliability.

  • PDF

A Study on Printimage Enhancement and Realization of Electrothermal Printer Using Thermal Historic Management (열이력제어를 이용한 감열프린터의 인쇄이미지 향상 및 구현에 관한 연구)

  • 김영빈;허창우;류광렬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.213-216
    • /
    • 2002
  • The system realization for printimage enhancement of electrothermal printer using thermal historic management is presented. The thermal historic control technique reduces the blur that the high density thermal print head(TPH) and high speed printing in the 300dpi high is increased edge blur of printed image. The experiment result is that the system enhance the quality of print image.

  • PDF

The thermal conductivity analysis of the SOI LIGBT structure using $Al_2O_3$ ($Si/Al_2O_3/Si$ 형태의 SOI(SOS) LIGBT 구조에서의 열전도 특성 분석)

  • Kim, Je-Yoon;Kim, Jae-Wook;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.163-166
    • /
    • 2003
  • The electrothermal simulation of high voltage LIGBT(Lateral Insulated Gate Bipolar Transistor) in thin Silicon on insulator (SOI) and Silicon on sapphire (SOS) for thermal conductivity and sink is performed by means of MEDICI. The finite element simulations demonstrate that the thermal conductivity of the buried oxide is an important parameter for the modeling of the thermal behavior of silicon-on-insulator (SOI) devices. In this paper, using for SOI LIGBT, we simulated electrothermal for device that insulator layer with $SiO_2\;and\;Al_2O_3$ at before and after latch up to measured the thermal conductivity and temperature distribution of whole device and verified that SOI LIGBT with $Al_2O_3$ insulator had good thermal conductivity and reliability

  • PDF

Results of Intradiscal Pulsed Radiofrequency for Lumbar Discogenic Pain: Comparison with Intradiscal Electrothermal Therapy

  • Fukui, Sei;Nitta, Kazuhito;Iwashita, Narihito;Tomie, Hisashi;Nosaka, Shuichi;Rohof, Olav
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.155-160
    • /
    • 2012
  • Background: We have developed an intradiscal pulsed radiofrequency (Disc PRF) technique, using Diskit $II^{(R)}$ needles (NeuroTherm, Wilmington, MA, USA), as a minimally invasive treatment option for chronic discogenic low back pain (LBP). The purpose of this study was to compare the representative outcomes of Disc PRF and Intradiscal Electrothermal Therapy (IDET) in terms of pain relief and reduction of disability. Methods: Thirty-one patients with chronic discogenic LBP who underwent either Disc PRF (n = 15) or IDET (n = 16) were enrolled in the study. A Diskit $II^{(R)}$ needle (15-cm length, 20-gauge needle with a 20-mm active tip) was placed centrally in the disc. PRF was applied for 15 min at a setting of $5{\times}50$ ms/s and 60 V. The pain intensity score on a 0-10 numeric rating scale (NRS) and the Roland-Morris Disability Questionnaire (RMDQ) were assessed pretreatment and at 1, 3, and 6 months post-treatment. Results: The mean NRS was significantly improved from $7.2{\pm}0.6$ pretreatment to$2.5{\pm}0.9$ in the Disc PRF group, and from $7.5{\pm}1.0$ to $1.7{\pm}1.5$ in the IDET group, at the 6-month follow-up. The mean RMDQ also showed significant improvement in both the Disc PRF group and the IDET group at the 6-month follow-up. There were no significant differences in the pretreatment NRS and RMDQ scores between the groups. Conclusions: Disc PRF appears to be an alternative to IDET as a safe, minimally invasive treatment option for patients with chronic discogenic LBP.

Preconcentration of Ultra Trace Amounts Bismuth in Water Samples Using Cloud Point Extraction with Na-DDTC and Determination by Electrothermal Atomic Absorption Spectrometry (ET-AAS) (Na-DDTC로 흐림점 추출을 사용한 물시료에서 초미량 비스머스의 예비농축)

  • Moghimi, Ali
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.2
    • /
    • pp.140-147
    • /
    • 2008
  • .A new approach for a cloud point extraction-electrothermal atomic absorption spectrometric method was used for determining bismuth. The aqueous analyte was acidified with sulfuric acid (pH 3.0-3.5). Triton X-114 was added as a surfactant and natriumdiethyldithiocarbaminat (Na-DDTC) was used as a complexing agent. After phase separation at 50oC based on the cloud point separation of the mixture, the surfactant-rich phasen was diluted using tetrahydrofuran (THF). Twenty microliters (20 L) of the enriched solution and 10 l of 0.1% (w/v) Pd(NO3)2 as chemical modifier were dispersed into the graphite tube and the analyte determined by electrothermal atomic absorption spectrometry. After optimizing extraction conditions and instrumental parameters, a preconcentration factor of 195 was obtained for a sample of only 10 mL. The detection limit was 0.04 ng ml-1 and the analytical curve was linear for the concentration range of 0.04-0.70 ng mL-1. Relative standard deviations were <5%. The method was successfully applied for the extraction and determination of bismuth in water samples.

An Investigation on Surgical Parameters for the Treatment of Intervertebral Disc during Electrothermal Therapy (디스크의 전기열치료시 수술변수에 관한 연구)

  • Jin E.D.;Choi J.S.;Tack G.R.;Lee B.S.;Lee B.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.513-514
    • /
    • 2006
  • Recently intradiscal electrothermal therapy is introduced, which is a new and minimally invasive technique fer the treatment of discogenic low back pain. This procedure involves the percutaneous threading of a flexible catheter into the disc under fluoroscopic guidance. The catheter, composed of thermal resistive coil, heats the posterior annulus of the disc, causing contraction of collagen fibers and destruction of afferent nociceptors. This study tries to investigate the effects of the important factors of this procedure such as heat source temperature and heat applying time on the temperature distribution within the intervertebral disc. This study utilized both computer simulation and the experiment for the verification of finite element analysis. FE analysis was carried out with ANSYS v7.0 (ANSYS Inc, USA) using 10,980 number of brick element and 12,551 number of node. The functional spinal units of 5 month old swine were used for the experiment and the temperature was monitored using 10 channel temperature measurement device MV200. Through this study, it was able to analyze the temperature range of inner intervertebral disc by two mechanisms which are known to alleviate pain clinically. The results showed that when the heat source temperature was kept up 80 degree for 1,020 seconds, the temperature of inner annulus reached at 45 degree up to the distance of 15.6mm from heat source, which explains coagulation of inner annulus by heat. When the same heat source was used, the temperature of inner nucleus reached at 60 degree up to the distance of 9mm from heat source, which explains contraction of inner nucleus by heat.

  • PDF

Thermal Memory Effect Modeling and Compensation in Doherty Amplifier (Doherty 증폭기의 열 메모리 효과 모델링과 보상)

  • Lee Suk-Hui;Lee Sang-Ho;Bang Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.9 s.339
    • /
    • pp.49-56
    • /
    • 2005
  • Memory effect, which influence the performance of Doherty amplifier, become more significant and critical in designing these circuits as the modulation signal bandwidth and operation power level increase. This paper reports on an attempt to investigate, model and quantity the contribution of the electrical nonlinearity effects and the thermal memory effects to a Doherty amplifier's distortion generation. Also this raper reports on the development of an accurate dynamic expression of the instantaneous junction temperature as a function of the instantaneous dissipated power. This expression has been used in the construction of an electrothermal model for the Doherty amplifier. Parameters for the nelv proposed behavior model were determined from the Doherty amplifier measurements obtained under different excitation conditions. This study led us to conclude that the effects of the transistor self-heating phenomenon are important for signals with wideband modulation bandwidth(ex. W-CDMA or UMTS signal). Doherty amplifier with electrothermal memory effect compensator enhanced ACLR performance about 20 dB than without electrothemal memory effect compensator. Experiment results were mesured by 60W LDMOS Doherty amplifier and electrothermal memory effect compensator was simulated by ADS.

Thermal-Induced Osteonecrosis of Adjacent Vertebra after Intradiscal Electrothermal Therapy

  • Kim, Soonjoon;Lee, Sun-Ho;Kim, Eun-Sang;Eoh, Whan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.1
    • /
    • pp.114-117
    • /
    • 2017
  • A 42-year-old man was admitted to our hospital with complaints of low back pain and intermittent right thigh pain. Twelve weeks before admission, the patient received intradiscal electrothermal therapy (IDET) at a local hospital. The patient still reported low back pain after the procedure that was managed with narcotic analgesics. Follow-up magnetic resonance imaging (MRI) was performed, and his referring physician thought the likely diagnosis was spondylodiscitis at the L4-5 spinal segment with a small epidural abscess. At admission to our department, the patient reported aggravated low back pain. Blood test results, including the erythrocyte sedimentation rate and C-reactive protein levels, were slightly elevated. Biopsy samples of the L4, L5 vertebral bodies and disk were obtained. The material underwent aerobic, anaerobic, fungal, mycobacterial cultures and histologic examination. Results of all cultures were negative. Histologically, necrosis of the bone was evident from the number of empty osteocyte lacunae. In addition, there was no evidence of infection based on biopsy results. No antibiotic treatment was administered on discharge. Repeat computed tomography and MRI performed 12 months after IDET showed a bony defect in the L4 and L5 vertebral bodies, and a decrease in the size of the L4-5 intervertebral disc lesion. We report a case of lumbar vertebral osteonecrosis induced by IDET and discuss etiology and radiologic features.

The Fundamental Studies and Development of Modified Electrothermal Vaporization Hollow Cathode Glow Discharge Cell (개선된 전열증기화 속빈음극관 글로우 방전셀의 기초연구 및 개발)

  • Lee, Seong-Hun;Cho, Won-Bo;Jeong, Jong-Pil;Choi, Woo-Chang;Kim, Kyu-Whan;Woo, Jeong-Su;Lee, Chang-Su;Kang, Dong-Hyun;Lee, Sang-Chun
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.514-520
    • /
    • 2002
  • The electrothermal vaporization (ETV) hollow cathode glow discharge atomic emission spectrometer for analysis of liquid sample has been developed and characterized. This system has improved the sample introduction method of electrothermal vaporization and the hollow cathode glow discharge. The sample introduction method was possible to provide high analyte transport efficiency to the plasma by helix coil made of tungsten material. In addition, small volume samples (<$30{\mu}{\ell}$) could be used. The system has glow discharge cell with special design for improvement of precision. The effect of discharge parameters such as discharge power, gas flow rate has been studied to find optimum condition. The emitted light was effectively carried into detector by fiber optic cable in UV region. The calibration curve of Pb, Cd were obtained with 3 samples.