• Title/Summary/Keyword: Electrotechnical regulation

Search Result 6, Processing Time 0.019 seconds

Consideration for Confirmity Assessment of Eco-friendly Public Transportation System based on the Wireless Power Transfer Technology (무선 전력전달 방식 친환경 대중교통 시스템의 적합성 평가에 대한 고찰)

  • Shin, Jung-Jin;Kim, Gi-Hyun;Lee, Kang-Hee;Kim, Han-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1524-1528
    • /
    • 2012
  • According to the Article 4(Confirmity Assessment)of the Electrotechnical Regulation, Confirmity Assessment for the Electrotechnical Regulation decides confirmity of Electrotechnical Regulation; whether to satisfy performances and requirements(determined from Electrotechnical Regulation). It evaluates technical requirements, new technology and standards. However, it does not evaluate technical content stated from Electrotechnical Regulation & Conformity Criteria. From Confirmity Assessment, the technology will be decided whether to fulfill performances and technical requirements. Which is predetermined by contents related to Electrotechnical Regulation. Test standards and test conditions will be overlooked to determine its performances and technical requirements for safety. This paper will show that, studies have been done to determine the guideline for Confirmity Assessment, which is evaluated from performances and technical requirements associated with Confirmity Assessment of electrical installation for new technology of wireless power transfer.

A Study on the Introduction of Electrical Installation Verification for International Electrotechnical Commission(IEC) (IEC 표준에 의한 검증기준 도입 필요성에 관한 연구)

  • Lee, Geum-Hwan;Lee, Kang-Hee;Kim, Jun-Taek;Shin, Ki-Hyun;Lee, Hyo-Jin;Kim, Han-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1625-1626
    • /
    • 2015
  • 현재 제정 중에 있는 한국전기규정(KEC)은 국제전기표준인 IEC를 기반으로 제정 중에 있으며, 이에 따라 과거의 기준과 다른 IEC 기반의 전선 굵기, 차단용량, 접지방법 등을 적용할 수 있게 되었다. 그중에서 전선의 굵기와 차단기의 차단용량과 관련된 사항은 이미 국내 기술기준에 반영되어 적용되고 있다. 그러나 접지방법 및 체계에 대한 사항은 아직도 적용을 위해 충분하게 논의되지 않은 상태이다. 따라서 IEC를 기반으로 시설된 전기설비의 검증방안을 모색하여 KEC의 조기정착 및 전기설비안전을 확보하고자 한다.

  • PDF

A Study on a Regulation Draft of Inspection and Maintenance for Lightning Protection Facilities based on IEC 62305 (국제표준(IEC 62305) 도입에 따른 피뢰시스템 검사 및 유지관리에 대한 연구)

  • Lee, Kang-Hee;Lee, Sang-Hyup;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.838-844
    • /
    • 2015
  • Latest development of ICT makes building, including houses, factories and public facilities, more intelligent and automatized. It follows that a wide variety of electric and ICT installations are adopted along with micro electronic equipments. Corresponding to such changes, the frequency of lightning increases due to the abnormal climate. The major damage by lightning surge is disconnection and malfunction of facilities. It is necessary, therefore, to make a regulation of inspection and maintenance for lightning protection facilities. This paper deals with main issues of a regulation draft of inspection and maintenance for lightning protection facilities based on IEC 62305

Guideline Development to Evaluate the Safety and Performance of Intense Pulsed Light(IPL) (Intense Pulsed Light의 안전성 및 성능평가를 위한 시험 항목 및 시험방법(안) 연구)

  • Kang, Dong-Yeon;Son, Tae-Yoon;Joo, Yea-Il;Choi, Eung-Ho;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.129-133
    • /
    • 2010
  • Intense pulsed light(IPL) is a photo-therapeutic medical device using xenon lamps with optical characteristics of incoherence, defocusing, and polychromatic. IPL has been recognized as a representative medical therapeutic device with growth of domestic skin care market. However, there is no standard regulation manual and guideline to evaluate the safety and performance of IPL. International Electrotechnical Commission(IEC) is being statued "Technical Report IEC TR 60825-16" which is a guidelines for the safe use of intense light source equipment on humans and animals. In this study, a standard Korea Food & Drug Administration (KFDA) regulation for the safety and performance of IPL was suggested by developing minimal evaluation methods for optical parameters of IPL such as output energy density, pulse mode, spot size, wavelength and uniformity of output light. We expect that this study may be a step to statue a standard regulation manual and guideline for IPLs used in domestic.

A Study on the SAR Measurement System Validation at 150 MHz Band (150 MHz 대역에서의 SAR 측정시스템의 유효성 연구)

  • Choi, Donggeun;Kim, Kihwea;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.10
    • /
    • pp.1008-1016
    • /
    • 2013
  • SAR measurement which was applied only to the mobile phone has been expanded in the Korean radio regulation law to the portable wireless communication equipments within 20 cm from the human body since Jan. 2012. The two-way radio operating at 150 MHz frequency band was newly included following the revised radio regulation in the target equipment of measurement. SAR measurement system at 150 MHz satisfying this regulation is necessary accordingly for SAR conformity assessment. The international SAR measurement standard(IEC 62209-2) includes the evaluation method on frequencies above 300 MHz, and the commercial SAR measurement system can measure SAR above 300 MHz only. The size of the reference dipole antenna(760 mm, return loss: -27.57 dB) and flat phantom ($1,300 mm(L){\times}900 mm(W){\times}200 mm(H)$), targeted SAR values for numerical analysis(1 g: 1.08 W/kg, 10 g: 0.77 W/kg) for SAR validation evaluation at 150 MHz frequency are proposed in this paper. The suggested dipole antenna and flat phantom are assembled and used to verify the conformity assessment of commercial SAR measurement system. The measured SAR values of 1 g and 10 g were obtained respectively to be 1.13 W/kg, 0.81 W/kg, and they satisfied the effective range(within ${\pm}10$ %) of IEC international standard. The standards based on this study are expected to be used for the domestic SAR measurement standard and IEC(International Electrotechnical Commission) international standard.

Development of a Techniques of the Performance Test for a Radiation Protection Devices and it's International Standards (방사선 방호용 계측기 성능평가 기술 개발 및 국제 표준)

  • Choi, Kil-Oung;Won, Sung-Ho;Kim, Jung-Ho;Hah, Suck-Ho;Yi, Chul-Young;Kim, Hyun-Moon;Lee, Min-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • International Standardization in all technical area is gaining its momentum as its impact and implication over global trade is directly linked. The worldwide competition to secure a dominant position in the standardization process is ever growing over the years. In 2005, the International Technical Committee on Nuclear Instrumentation, which is a subunit of International Electro-technical Commission (IEC), was held in Korea under the auspices of MOST (Ministry of Science and Technology). Korea has adopted its Rule and Regulation as the National Standard. As a part of a link to National Mid-and Long-term Atomic Energy R&D Program of MOST, the technical development of a performance test for the radiation monitors was carried out under mechanical environment and electromagnetic immunity conditions. The characteristics of the radiation fields were also evaluated under the conditions and introduced to a techniques of performance test for the radiation protection instrumentation adopted IEC61526 standards and it's results was analyzed. We would like to share the experience gained in these efforts, failure as well as success, and to discuss the problems encountered and serious consideration to be taken into account in the future endeavor.