• 제목/요약/키워드: Electrostatic Precipitator

검색결과 198건 처리시간 0.028초

전기집진기형 공기청정기의 미세 먼지 저감 특성에 관한 연구 (Characteristics of the Reduction of Fine Particles in an Indoor Air Cleaner Using Electrostatic Precipitation Technique)

  • 목영선;이호원
    • 한국산업융합학회 논문집
    • /
    • 제7권1호
    • /
    • pp.115-120
    • /
    • 2004
  • An indoor air cleaner consisting of a dielectric barrier discharge system and an electrostatic precipitator (ESP) was experimentally investigated. The function of the dielectric barrier discharge is to precharge particles by producing nonthermal plasma before indoor air enters ESP, leading to an enhancement in dust collection efficiency. The dependence of particle size distribution on the plasma discharge was examined to understand the mechanism of the particle precharging. The plasma discharge was found to increase the electrical force of the particles, rather than agglomerate them. Coarse particles in the range of 0.5 to $5.0{\mu}m$ were observed to be easily collected by this indoor air cleaner, and the present study laid emphasis on the removal of fine particles of $0.3{\mu}m$. The collection efficiency of the fine particles was largely enhanced by the plasma discharge.

  • PDF

$CO_2$ 농후 조건에서 전기집진장치의 Submicron 입자 제거 특성 (Removal characteristics of submicron particles with electrostatic precipitator under $CO_2$ rich condition)

  • 김학준;한방우;송동근;정상현;원종웅;김용진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2116-2121
    • /
    • 2008
  • Removal of particles at rich $CO_2$ condition has been important in the gas cleaning for $CO_2$ capture in Oxy-fuel combustion. Electrostatic precipitators (ESPs) have been widely used to remove particles in exhaust gases from present air combustion. However, few studies on characteristics of ESPs under a $CO_2$ rich gas condition have been conducted. In this study, we investigated integration of electrostatic precipitators (ESP) for removing submicron particles along with corona discharge characteristics and collection efficiency of submicron particles at $CO_2$ rich condition. The overall performance of ESP is represented by collection efficiency as function of energy consumption. The experiment results showed that higher the concentration of $CO_2$ gas, the corona discharge currents were lower at the same applied voltages and the spark over occurred at lower voltages, and the collection efficiency of submicron particles under 50, 80% $CO_2$ conditions was much lower than that under 100% Air.

  • PDF

전기집진기의 직렬 및 병렬식 배열에 따른 효율적인 진동 탈진에 대한 연구 (Research for Effective Vibrational Rapping Performance of Multiple Electrostatic Precipitators in Series and Parallel Arrangements)

  • 최지현;김진호
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4136-4141
    • /
    • 2013
  • 전자기 진동 가진기를 적용한 전기 집진기의 효과적인 탈진 여부를 판단할 수 있는 기준은 집진기내 집진판들의 진동 가속도이다. 이러한 진동 가속도는 외부로부터의 가진 주파수와 시스템의 고유주파수의 일치로 인하여 공진이 일어날 때 간헐적으로 최대치를 보이며 효율적인 탈진성능을 기대할 수 있다. 본 연구에서는 한대의 전자기 진동 가진기를 이용하는 단일 객체를 대상으로 한 관점에서 더 나아가, 실제 현장에서 복수의 전기집진탈진기가 설치됨을 고려하여 진동 탈진기의 설치방식에 따라 시스템을 모델링 하였다. 이러한 직렬 및 병렬회로로 연결된 가진기를 적용한 시스템을 대상으로 진동 가속도 계측 실험을 수행하여 직렬 및 병렬식 연결에 따른 진동 가속도의 차이를 비교함으로써 가진기의 배열 방식과 그에 따른 기대 탈진 성능 및 소비전력의 유효성을 검증하였다. 최종적으로 직렬 배열형 모듈이 증가할수록 선형적으로 필요전류량이 증가할 것으로 예상하였으나 급격한 감소나 (6.9% ~ 37.6%) 증가를 (5% ~ 45%) 보여주었다. 단독의 가진기가 사용된 병렬 배열보다, 2대의 가진기가 사용되고 그 전기회로의 연결이 병렬일 때 동일한 전류가 인가되었음에도 약 11.64% 의 가속도 감소 현상을 보였다. 2대의 가진기를 사용하고 입력전류의 값을 소비 전력의 관점에서 동일하게 보정하였을 경우 약 16.80 % 의 가속도 증가 현상을 확인하였다.

중첩펄스 전기집진기의 전력 및 집진특성 (Power and Collection Characteristics of Superimposed Pulse Electrostatic Precipitator)

  • 서경원;이창신;이정석;채재우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.177-185
    • /
    • 2000
  • In this study, the characteristics of various electricity and high resistivity ash collection were measured at superimposed nanosecond pulse energization. The pulse was generated through the hydrogen thyratron. Superimposed pulse was nanosecond duration pulse that had fast pulse rising time 100[ns], short pulse width 500∼850[ns] and pulse fall time 400∼750[ns]. The results of this study are summarized as followings; Frist, compared with the DC ESP(electrostatic precipitator), superimposed pulse ESP could induce higher peak voltage, and had the about 30[%] reduction of ESP collection area and 50∼80[%] reduction of power consumption. showing the same efficiency. Second, enhancement factor H had 1.9∼3.6 with the increase of migration velocity.

  • PDF

황산암모늄 주입에 따른 전기집진기(ESP)에서의 미세분진 제거 (A Study on Fine Particle Removal of ESP according to $(NH_4)_2SO_4$ Injection Rate)

  • 서정민
    • 한국환경과학회지
    • /
    • 제7권4호
    • /
    • pp.505-510
    • /
    • 1998
  • This study has been carried out to investigate Electrostatic Precipitator's(ESP) performance enhancement and removal efficiency of fine particle according to (NH4)2SO4injection rate. The following conclusions are derived from the these test results : 1) For plant condition cases, according to the variation of concentration agent [(NH4)2SO4]-10ppm, when inlet dust loading was 2g/m2. And when Inlet dust loading was 3g/m", that was increased to 98 19% 99.16% 99.23%, 99.58%, 2) It Is seen from thins experiments that the increasing 30ppm concentration of (NH4)2SO4 increase the collection efficiency and fine particle omission control.

  • PDF

전기집진장치의 효율 개선을 위한 풍속 분포 및 입자농도 분포의 영향 (Influence of the Distribution of Wind Velocity and Mist Concentration for the Improvement of Efficiency with an Electrostatic Precipitator)

  • 임헌찬;이덕출
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.155-161
    • /
    • 1998
  • Recently, there are widely needs of small scale electrostatic precipitator(ESP) in machine shop and other factories. Since the space of such factories is limited, the improvement of collection efficiency is predominant subject. In this study, we examine the influence of distribution of wind velocity and oil mist concentration inside the ESP in order to improve the performance of the ESP. The distribution of wind velocity and mist concentration is measured respectively in a cross-sectional plane of the ESP. The former is controlled by using a louver which is placed in front of an ionizer and the latter is controlled by lengthening the pipe of entrance of the ESP in order to have plenty of time that mist is dispersed evenly. It is shown that the uniformity of distribution of wind velocity and mist concentration inside the ESP can be getting by adopting a louver with proper shape and lengthening the pipe of entrance and is also contributed to collection efficiency considerably.

  • PDF

활성탄으로 코팅된 집진전극의 BTEX 흡착특성 (Adsorption Characteristics of BTEX on Dust Collecting Electrode Coated with Activated Carbon)

  • 남상철;김현정;김광수
    • 한국대기환경학회지
    • /
    • 제29권6호
    • /
    • pp.773-779
    • /
    • 2013
  • This study was performed to provide the basic data for the function of BTEX removal for compact electrostatic precipitator which are applicable to indoor environment (or closed spaces). For this purpose, the adsorption equilibrium test was conducted for BTEX of activated carbon sheet (ACS) and activated carbon (AC), and the adsorption characteristics of AC and ACS were evaluated using the Langmuir constant which was obtained from the adsorption characteristics, adsorption capacity and regression calculation. The surface area and adsorption pore volume of ACS reduced by 70% and 86%, respectively, as compared to those of AC, and the adsorption capacities of BTEX also showed a similar level. Thus, it is considered that ACS applied electrostatic precipitator is able to remove dust and BTEX simultaneously.

Development of Capacitance Measuring Equipment for Electrostatic Precipitator

  • Kim, Seung-Min;Lee, Sung-Jin;Nam, Jung-Han;Cho, Chang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.128.2-128
    • /
    • 2001
  • Since pulse energization can improve the performance of Electrostatic Precipitator(ESP) for high resistivity dusts, high voltage micro-pulse generators, 70kV 140usec duration pulses for instance, are commonly developed by LC resonance for most pulse powered ESPs. Consisting of discharge electrodes and collecting electrodes, ESP has its own capacitance like a capacitor. ESP's capacitance affects the LC resonance phenomenon with resonance inductor and capacitor of micro-pulse power supply, engineers should acquire the value of their ESP to design for proper power supply design. In this study, we describe the ESP's capacitance measuring device which has the same topology with our new developed micro-pulse power supply. In this microcontroller based capacitance measuring equipment, ESP's capacitance can be calculated easily through ...

  • PDF

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

1단 전기집진기에서 난류확산과 2차유동이 입자의 농도분포에 미치는 영향 (Effects of Turbulence Diffusion and Secondary Flows on the Particle Concentration Distribution in Single Stage ESP)

  • 정상현;김상수;김용진
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2271-2282
    • /
    • 1995
  • Numerical simulations for the effects of secondary flow and turbulence diffusion on the particle concentration distributions have been carried out for the single stage electrostatic precipitator. The electrohydrodynamic secondary flow, particle concentration distribution and collection efficiency have been evaluated as a function of dimensionless parameters such as Re, $N_{end}$, $P_{e}$ x. The results of simulations show that for increasing secondary flow intensity the concentration distribution is drastically deformed and collection efficiency is decreased which is more than due to turbulent diffusion.n.n.