• 제목/요약/키워드: Electronic wire

검색결과 589건 처리시간 0.037초

로울링법을 이용한 고온 초전도 다심선재 제조 (Fabrication of multi-layer $high-T_c$ superconducting tapes by a rolling process)

  • 김민기;허원일;최명호;한병성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권6호
    • /
    • pp.600-604
    • /
    • 1996
  • High-T$_{c}$, superconducting wire is very important element for the application of electrical power systems. But it is very difficult to develope the long high T, wire with excellent properties. BiSrCaCuO multi-layer tapes are fabricated by a rolling method and pressing method sintered for several step at 840.deg. C. The critical current densities of 637 filament multi-layer tapes sintering 100 hours fabricated by the rolling method and pressing method are 1.3*10$^{4}$ A/cm$^{2}$ and 5.5*10$^{3}$ A/cm$^{2}$. The critical cur-rent densites of multi-layer tapes made by rolling method are found to be better than those fabricated by the powder-in-tube method and pressing process. As result, the rolling method is the best way to fabricated the multi-layer filament.t.

  • PDF

아몰퍼스 자왜 와이어의 제작에 관한 연구 (A Study on the Fabrication of Amorphous Magnetostrictive Wire)

  • 김대주;정왕일;조남희;신용진;강재덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.99-101
    • /
    • 1996
  • This paper is concerned with the fabrication of (Fe,Co)-Si-B amorphous magneto-strictive wire which attracts strong attention as a new sensor material. First, we put the ingot of (Fe$\sub$1-x/Co$\sub$x/)$\sub$77/Si$\sub$8/B$\sub$15/ composition into quartz tube. Then, under the condition of 400MHz and 8kW, we melt and mix the in-got in the high frequency induction furnance. After that, we obtain the magnetostrictive wire of 100∼150$\mu\textrm{m}$ in diameter by injection and rapid quenching within the high rotating water. Finally, we find that the wire is under the amorphous state.

  • PDF

송전선 강심의 비틀림 특성에 미치는 열처리의 영향 (The effect of heat treatment on torsion characteristics of core for transmission conductors)

  • 김정훈;김봉서;김상수;현석규;김병걸;이희웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.526-528
    • /
    • 2003
  • The effect of heat treatment on torsion characteristics of high nitrogen steel wire has been studied by using torsion test, micro vickers hardness and scanning electron microscopy. After heat treatment at $600{\sim}700^{\circ}C$, the torsion cycle was increased with increasing temperature. Especially, in case of high nitrogen steel wire heat treated at $600^{\circ}C$, the torsion cycle was sharply increased. It is estimated that the cold-worked high nitrogen steel wire started to recrystallize around at $650^{\circ}C$ in air atmosphere.

  • PDF

The Effect of Manipulating Package Construct and Leadframe Materials on Fracture Potential of Plastically Encapsulated Microelectronic Packages During Thermal Cycling

  • Lee, Seong-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • 제2권3호
    • /
    • pp.28-32
    • /
    • 2001
  • It was studied in the present work how the thermal cycling performance of LOC (lead on chip) packages depends on the package construct or leadframe materials. First, package body thickness and Au wire diameter were manipulated for the selection of proper package design. Secondly, two different types of leadframe materials (i.e. copper and 52%Fe-48%Ni alloy) were tested to determine the better material for improved reliability margin of plastically encapsulated microelectronic packages. This work shows that manipulating package body thickness was more effective than an increase of Au wire from 23$\mu\textrm{m}$ to 33$\mu\textrm{m}$ for the prevention of wire debonding failure. Further, this work indicates that the LOC packages including the copper leadframes can be more susceptible to thermal cycling reliability degradation due to chip cracking than those including the alloy leadframes.

  • PDF

산불에 의한 가공송전선의 열화거동 (The Aging Behavior of Overhead Conductor due to Forest Fire)

  • 김병걸;김상수;한세원;김진한
    • 한국전기전자재료학회논문지
    • /
    • 제20권12호
    • /
    • pp.1105-1111
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about aging behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800\;^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90 %. The detailed results will be given in the text.

입자법을 이용한 와이어.이온.플라즈마원의 해석 (Numerical Analysis of Discharge in Wire ion Plasma Source)

  • 송태헌;고광철;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.369-372
    • /
    • 1997
  • Wire Ion Plasma Source (WIPS) is a plasma device which has a thin wire anode, a coaxially-set cylindrical cathode and electrodes located in both ends of the cylinder. The potential between the anode and cathode changes logarithmically by this electrode configuration. This electrode configuration enables high-density plasma to produce even at a low anode voltage. Since the electrode configuration is axially symmetric and long. plasma with axially uniform number density can be produced. Using particle-in-cell(PIC) and Monte Carlo collision(MCC), we investigate the traiectory of electrons and the characteristics of D.C. discharge in Wire ton Plasma Source.

  • PDF

와이어 본딩시 본딩 패드 리프트 불량에 관한 연구 (Study on the Bonding Pad Lift Failure in Wire Bonding)

  • 김경섭;장의구;신영의
    • 한국전기전자재료학회논문지
    • /
    • 제11권12호
    • /
    • pp.1079-1083
    • /
    • 1998
  • In this study, ultrasonic power of Aluminum wire bonder, bond time and bond force are investigated and valued in order to minimize failure of bonding pad lift. We also tried to control those 3 factors properly. We got the conclusion that if we turn down the ability of ultrasonic power or bond time, we can get a pad lift from a boundary between bond pad ad wire because pad metal and wire joining is unstable, but it is best condition when it ultrasonic power is 100∼130unit, bond time is 15∼20msec and bond force is 4∼6gf.

  • PDF

산불에 의해 가열된 가공송전선의 이도거동 (The SAG Behavior of Overhead Conductor due to Forest Fire)

  • 김병걸;김상수;전완기;한세원;김진한
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.516-517
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about sag behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. and then sag of overhead conductor become deteriorated. The detailed results will be given in the text.

  • PDF

하이브리드 절연필름의 전동기권선 적용 특성 연구 (Technology and Application of Hybrid Insulation Film for Electric Magnet Wire)

  • 한세원;한동희;강동필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.210-211
    • /
    • 2006
  • This study presents the technology and application of hybrid insulation film for electric magnet wire. In order to make the high efficient motor with high space factor, it is necessary to develop a self-lubrication heat-resistant insulation film that can be used when the space factor 70% or more. A key to achieving high windability is to increase the lubricity and bonding strength of vanish, which for a magnet wire generally determines the mechanical scratches characteristics. Effective ways to reduce scratches include improving insulation film prepared by organic and inorganic hybrid synthesis methods.

  • PDF

산불에 의한 가공송전선의 열화거동 (The Aging Behavior of Overhead Conductor due to Forest Fire)

  • 김병걸;김상수;전완기;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.534-535
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about aging behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. The detailed results will be given in the text.

  • PDF