• 제목/요약/키워드: Electronic skin

검색결과 252건 처리시간 0.025초

PVDF 필름을 이용한 힘과 온도 동시검지에 대한 연구 (A study of Simultaneous Force and Temperature Sensing with PVDF Film)

  • 이용국;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.690-693
    • /
    • 2002
  • This paper is concerned on method of simultaneous force(stress) and temperature sensing with PVDF film. PVDF film has piezoelectric and pyroelectric properties. Therefore, it senses changes of stress and temperature. But it's output is affected with two properties. Using different medium in a sensing element, this problem is solved. Two structures induce different equations that its solutions are changes of stress and temperature. This method and result is applicable in skin sensor that has complexity of material and structure.

  • PDF

컬러 시각을 이용한 사람 손의 검출 (Human Hand Detection Using Color Vision)

  • 김준엽;도용태
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.28-33
    • /
    • 2012
  • The visual sensing of human hands plays an important part in many man-machine interaction/interface systems. Most existing visionbased hand detection techniques depend on the color cues of human skin. The RGB color image from a vision sensor is often transformed to another color space as a preprocessing of hand detection because the color space transformation is assumed to increase the detection accuracy. However, the actual effect of color space transformation has not been well investigated in literature. This paper discusses a comparative evaluation of the pixel classification performance of hand skin detection in four widely used color spaces; RGB, YIQ, HSV, and normalized rgb. The experimental results indicate that using the normalized red-green color values is the most reliable under different backgrounds, lighting conditions, individuals, and hand postures. The nonlinear classification of pixel colors by the use of a multilayer neural network is also proposed to improve the detection accuracy.

Effect of 8 mW 525 nm LEDs Light Irradiation on the Defect Reduction in the Skin Wound of SD-rat

  • Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권3호
    • /
    • pp.116-119
    • /
    • 2008
  • The purpose of this study is to develop the Photodynamic Therapy Equipment for medical treatment. We developed the equipment which was helpful in palpating wound healing by using 525 nm LEDs. The equipment was assembled with a micro-controller and green color LEDs, and designed to enable us to control light irradiation time, intensity and so on. In this study, the designed device was used to find out how 525 nm LEDs light affected the skin wound of SD-Rat(Sprague-Dawley Rat). We divided the participants into two groups; irradiation group which was irradiated one hour a day for 9 consecutive days, and none irradiation group. The results showed that the study group had lower incidence of inflammation and faster recovery, compared with the control group.

새로운 RGB영역 변환을 이용한 Skin Color Detection에 관한 연구 (A Study on New RGB Space Transformation for Skin Color Detection)

  • 정원석;이형지;정재호
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2000년도 추계학술발표논문집 (하)
    • /
    • pp.915-918
    • /
    • 2000
  • 본 논문에서는 색상정보를 이용한 얼굴 검출 알고리즘에 대해 소개하고자 한다. 여러 개의 얼굴 검출에 적용되는 이 알고리즘은 피부색의 학습 과정과 입력영상에 대한 얼굴 검출 과정으로 크게 두 가지로 나눌 수 있다. 특히 본 연구에서는 피부색이 본 논문에서 제안한 새로운 RGB 영역에서 직선을 이루는 특징을 이용하여 학습 data를 구성한다. 이렇게 구성된 data를 입력영상에 적용함으로써 1차 얼굴 후보영역을 결정한다. 그런 후 1차 후보영역을 세로방향과 가로방향으로 투영시킴으로써 최종 얼굴영역을 찾아낸다. 실험을 통해 이 알고리즘은 기존의 색상정보를 이용한 얼굴 검출 방법에 비해 얼굴개수에 상관없이 높은 검출 성공률을 보여주었다.

  • PDF

Design of Mobile Display Color Control Algorithm Using Red and Blue Color Emphasis with Skin Color Protection

  • Ha Joo-Young;Kim Joo-Hyun;Yang Hoon-Gee;Kang Bong-Soon
    • 한국통신학회논문지
    • /
    • 제31권3C
    • /
    • pp.264-270
    • /
    • 2006
  • In this paper, we propose the modified display color control system using white point line, boundary lines and S-shaped curves to emphasize blue and red tone colors on CIE1931 diagram. The proposed system divides RGB gamut into movable area and non-movable area by using boundary lines. The colors in movable area are moved into right side or left side along quadratic curve to change the bluish (or reddish) color to more bluish (or more reddish), while those in non-movable area are excepted from color control to prevent skin color from changing. The loci of the quadratic curves are very similar to the arc of the white-point line which connects all points that represent the chromaticities of a black body radiator at different temperatures and is also called the black body locus. The RGB gamut extension by movement of chromaticity coordinate can improve color reproducibility. Therefore in the case of application to LCD, the display shows excellent performance because the LCD's color reproducibility is comparatively lower than that of other display systems. The proposed system is also experimentally demonstrated with Xilinx Virtex FPGA XCV2000E- 6BG560 and the TV set.

고밀도 유도 결합 플라즈마 장치의 SiH4/O2/Ar 방전에 대한 공간 평균 시뮬레이터 개발 (Development of High Density Inductively Coupled Plasma Sources for SiH4/O2/Ar Discharge)

  • 배상현;권득철;윤남식
    • 한국진공학회지
    • /
    • 제17권5호
    • /
    • pp.426-434
    • /
    • 2008
  • 고밀도 유도결합 플라즈마 장치의 $SiH_4/O_2/Ar$방전에 대한 공간 평균 시뮬레이터를 제작하였다. 제작된 시뮬레이터는 $SiH_4/O_2/Ar$ 플라즈마 방전에서 발생되는 전자, 양이온, 음이온, 중성종, 그리고 활성종들에 대해 공간 평균한 유체 방정식을 기반으로 하고 있으며, 전자가열 모델은 anomalous skin effect를 고려한 파워 흡수 모델을 적용하여 전자가 흡수하는 고주파 파워량을 결정하였다. 완성된 시뮬레이터에서 RF-파워와 압력 변화에 대한 하전입자, 중성종, 활성종들의 밀도 변화 및 전자 온도 의존성을 계산하였다.

가열과 운동에 의한 생체조직내의 생리적 변화에 따른 광학적 특성의 변화에 관한 연구 (The Effects of Physiological Heating and Exercise on the Optical Properties of Biological Tissue.)

  • 임현수;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.81-88
    • /
    • 1993
  • This paper is the study of the reflectance of light from biological tissue for red and Infrared wavelengths and relates the acquired reflectance data to expected physiological changes within the skin and muscle layers associated with heat and exercise. The instrument was disigned to collect data from the calf muscle in human subjects with probe located at the surface of skin. Rapid data acquisition method allowed monitoring of rapid changes in reflecttance due to a stimulus. This study demonstrates that changes in O2 saturation and blood fractional volume expected within the dermis and muscle layers were asserted by examining the slopes of the plotted index for heat and exercise. The results presented in thls study support the claim that reflectance can separately discriminate between changes of blood volume and oxygenation in muscle and in skin. The data demonstrate the ability to measure consistent changes In tissue optical properties during exercise and heat.

  • PDF

전자파에 대한 지역사회 주민의 지식수준과 관련요인 (Community residents' knowledge level and related factor on electronic wave)

  • 이규수;남철현;김성우;김귀희
    • 보건교육건강증진학회지
    • /
    • 제19권3호
    • /
    • pp.73-85
    • /
    • 2002
  • This study was conducted to examine community residents' knowledge level and related factor on electronic wave in order to provide basic data for development of education and publicity program. 2,000 people, who lived in five big cities and five small and medium cities, were selected ad subjects of this study. The data were collected from May 1, 200 I to August 31, 2001. The results of this study are as follows. According to the average knowledge level of harmful affect of electronic wave on health in general characteristics, female was higher(37.40 ± 5.24 points) than male; ‘forties’ was highest(37.77 ± 5.69 points); ‘married spouse’ was high(36.84 ± 5.59 points); ‘living in small-ta-medium city’ was high(36.84 ± 5.32 points). ‘university graduate’ was highest(37.41 ± 5.32 points) in education level, ‘middle class’ was high(36.61 ± 4.96 points) in economic status, ‘professional technician’ was higher(36.68 ± 6.55 points) than other occupations in occupational type. According to the knowledge level of harmful affect of electronic wave on health in health condition by self-judgment, ‘good health condition’ was highest(36.77 ± 4.99 points). In the case of the knowledge level of those who visited medical institutions for last one year, ‘never visited’ was highest(37.19 ± 5.02 points). In the kind of medical institutions, ‘those who visited general hospital’ was highest(36.58 ± 5.63 points). In the way of knowledge obtainments of electronic wave through education and publicity media, ‘school education’ was highest(37.55 ± 5.19 points). According to the score of awareness level of disease incidence related to electronic wave, allergy and erethism was highest(57.8 points on the basis of 100 points). It appeared in order of leukemia, skin disease or skin cancer, dementia, various cancers, cataract, and brain tumor. The variables which significantly influenced knowledge level of harm of electronic wave were knowledge obtainments of electronic wave, age, economic status, daily TV watching period, sex, period of daily cellular phone use, period of working with computer, and daily VTR watching period. The knowledge of community residents concerning harmful affect of electronic wave on health is needed because people's opportunity of exposing to electronic wave is increasing. Especially, it is the demands of the times to provide information on knowledge of each equipment which generate electronic wave. The government, the product manufacturing companies, related social organizations, and education institutions must make efforts to develop the education program which is needed to make people have right knowledge and attitude.

경락노선상 직류 전위 측정에서의 문제점 (The Problems in the Measurement of DC Potential on Meridian Skin Area)

  • 허익범;이우철;이유정;인창식
    • 대한한의진단학회지
    • /
    • 제9권1호
    • /
    • pp.131-135
    • /
    • 2005
  • Background and purpose: The measurement of direct current (DC) potential on skin area of meridian has recently been adopted to explore the electrophysiological characteristics of meridian system, But there exists two problems to be explained; the entity of the DC potential to be measured and the characteristics of electrode gel interface of measurement system, It is not clear whether the DC potential reflect, at least hypothetically, the entity of meridian, and if there exist any unstable factor in the DC potential measurement system. Methods: In this study, we designed an electronic circuit model of skin and applied known DC potential sources $({\pm}10.75mV,\;0mV)$ to the electrode interface of the skin model. Results: The result showed that the measured DC potential changed according to the time, and the same phenomenon was observed when the electrode gel was replaced with an electric condenser. It is suggested that the measurement of DC potential on electrode gel interface is very difficult and produces unstable values due to the capacity effect of electrode gel. Conclusion: Further studies on the DC potential evaluation in the context of meridian study should consider and bypass this problem.

  • PDF