Study on the Positioning Method using BLE for Location based AIoT Service (위치 기반 지능형 사물인터넷 서비스를 위한 BLE 측위 방법에 관한 연구)

  • Ho-Deok Jang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2024
  • Smart City, a key application area of the AIoT (Artificial Intelligence of Things), provides various services in safety, security, and healthcare sectors through location tracking and location-based services. an IPS (Indoor Positioning System) is required to implement location-based services, and wireless communication technologies such as WiFi, UWB (Ultra-wideband), and BLE (Bluetooth Low Energy) are being applied. BLE, which enables data transmission and reception with low power consumption, can be applied to various IoT devices such as sensors and beacons at a low cost, making it one of the most suitable wireless communication technologies for indoor positioning. BLE utilizes the RSSI (Received Signal Strength Indicator) to estimate the distance, but due to the influence of multipath fading, which causes variations in signal strength, it results in an error of several meters. In this paper, we conducted research on a path loss model that can be applied to BLE IPS for proximity services, and confirmed that optimizing the free space propagation loss coefficient can reduce the distance error between the Tx and Rx devices.

Study on the EMC Engineering for Fixed Installations (복합설비를 위한 EMC 엔지니어링 연구)

  • Young-Heung Kang
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.798-803
    • /
    • 2023
  • In the industrial internet of things (IIoT) industry, including smart factories, there are many cases where electronic devices are complexly combined and installed due to the recent development of intelligent information technology. Electromagnetic waves generated from such complex facilities affect other devices and services, which can lead to safety issues. The problem such as electromagnetic interference (EMI) and electromagnetic compatibility (EMC) generated when controlling complex facilities is an essential element that must be solved, and the engineering basis for EMI and EMC must be established to foster the industry of complex facilities. Therefore, in this study, EMC & EMI engineering demonstration cases for solar power fixed facilities using the national standard guideline have been analyzed. The results show that the electromagnetic risk indices in the solar power facilities have been degraded up to control level, and a national EMC engineering system has been proposed for complex facilities.

Herbal Medicine for Sarcopenia: A Systematic Review of Randomized Controlled Trials (근감소증에 대한 한약 치료 : 체계적 문헌 고찰)

  • Se-eun Chun;Soo-hyung Lee;Yong-jeen Shin;Sun-ho Shin
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.6
    • /
    • pp.1118-1138
    • /
    • 2023
  • Objectives: Sarcopenia is an age-associated skeletal muscle disorder that can profoundly impact the health of elderly people. However, the efficacy of herbal medicine in sarcopenia is uncertain. This review aims to investigate evidence of the effect of herbal medicine on sarcopenia. Methods: We systematically searched 12 electronic databases for relevant randomized controlled trials (RCTs). Only trials that met the inclusion criteria were selected, and the characteristics of the included studies were extracted and synthesized in a narrative manner. The quality of the included studies was assessed using Cochrane's Risk of Bias (RoB) 2.0 tool. Results: 7 RCTs involving 672 participants with sarcopenia met the inclusion criteria. The intervention combining herbal medicine and conventional treatment (i.e., exercise, nutritional support) had a significant therapeutic effect compared with the conventional treatment, showing improvement in muscle strength (i.e., grip strength), muscle mass (i.e., appendicular skeletal muscle mass index), and physical function (i.e., gait speed, short physical performance battery, and timed up and go test). However, the methodological quality of the included RCTs was relatively low due to their high RoB, making it difficult to evaluate the efficacy of herbal medicine in sarcopenia. In terms of safety, several adverse events were reported. Conclusion: This review suggests that herbal medicine has a positive effect on muscle strength, muscle mass, and physical performance in elderly patients with sarcopenia, but there is a clear need for further research in this area.

Effect of belimumab in patients with systemic lupus erythematosus treated with low dose or no corticosteroids

  • Yeo-Jin Lee;Soo Min Ahn;Seokchan Hong;Ji-Seon Oh;Chang-Keun Lee;Bin Yoo;Yong-Gil Kim
    • The Korean journal of internal medicine
    • /
    • v.39 no.2
    • /
    • pp.338-346
    • /
    • 2024
  • Background/Aims: Systemic lupus erythematosus (SLE) responder index (SRI)-4 response has been achieved with belimumab treatment in patients with moderate disease activity in cornerstone clinical trials and following studies. However, most studies involved patients treated with a mean prednisolone-equivalent dose of approximately 10 mg/d and focused on the steroid-sparing effect of belimumab. We aimed to identify the effect of belimumab in patients with mild-to-moderate SLE who were treated with low-dose or no corticosteroids. Methods: We retrospectively reviewed the electronic medical records of patients treated with belimumab for at least 6 months between May 2021 and June 2022. The primary endpoint was SRI-4 response at 6 months. Results: Thirty-one patients were included (13 low dose- and 18 steroid non-users). The mean age was 39.2 ± 11.4 years, and 90.3% of patients were female. The baseline Safety of Estrogens in Lupus Erythematosus National Assessment-Systemic Lupus Erythematosus Disease Activity Index (SELENA-SLEDAI) score was 6.0 (4.0-9.0). The primary endpoint was achieved in 32.3% (10/31) of patients. Significant improvements in anemia, C4 levels, and SELENA-SLEDAI score were observed during treatment. Univariate analysis showed that the baseline SELENA-SLEDAI and arthritis were significantly associated with SRI-4 response at 6 months, and only the SELENA-SLEDAI remained significant (p = 0.014) in multivariate analysis. Conclusions: This cohort study is the first to report the efficacy of belimumab after minimizing the effect of corticosteroids. Belimumab showed efficacy in improving the SELENA-SLEDAI score, anemia, and low C4 in patients who did not receive corticosteroids or received only low doses.

Initial experience with Scepter Mini dual lumen balloon for embolization of cerebrovascular diseases

  • Muhammad U Manzoor;Ibrahim A. Almulhim;Abdullah A. Alrashed;Shorog Althubait;Abdulrahman Y. Alturki;Sultan M. Al-Qahtani
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.2
    • /
    • pp.175-181
    • /
    • 2023
  • Objective: Endovascular treatment of cerebrovascular diseases is often challenging due to small caliber, tortuous distal vessels. Several devices and techniques have evolved to overcome these challenges. Recently, a low profile dual lumen microballoon catheter, specifically designed for distal navigation is employed for neurovascular procedures. Due to its recent advent, scarce data is available on clinical utility and safety of Scepter Mini. The aim of this case series is to report our initial experience with Scepter Mini in the management of various cerebrovascular diseases. Methods: All interventional neurovascular cases performed using Scepter Mini between January 2020 till April 2021 were included. Data regarding patient demographics, procedural details and complications was retrospectively collected from patient's electronic medical record and procedure reports. Results: Total twelve embolization procedures were performed in eleven patients, including six brain arteriovenous malformation, two dural arteriovenous fistula, one vein of Galen malformation and three hyper-vascular glomus tumor embolizations. All procedures were successfully performed with adequate penetration of the embolic agent. Complete embolization was performed in six procedures, while intended partial embolization was performed in the rest of procedures. Scepter Mini was solely used in ten procedures, however in the other two embolization procedures it was used as an additional conjunct tool to complete the intended embolization. No balloon related complication was observed in any procedure. Conclusions: Scepter Mini dual lumen microballoon catheter is safe and feasible for delivery of liquid embolic agents for cerebrovascular embolization procedures.

A Study on the Diffusion Factor of e-finance (e-Finance의 확산요인에 관한 연구)

  • Kim, Min-Ho;Song, Chae-Hun;Song, Sun-Yok;Cha, Sun-Kwon
    • International Commerce and Information Review
    • /
    • v.4 no.2
    • /
    • pp.253-277
    • /
    • 2002
  • Nowaday, the advanced technology in information and communication has been leading the dramatic change of transaction paradigm expansion from physical basis to electronic one. As we know, financial services support most of financial exchange between two business parties. So the expansion of electronic transaction paradigm affects to every financial institutions which provide financial services. Thus, financial institutions have accepted e-Finance systems and providing internet financial services to live in the competition. The purpose of this study is to contribute the qualitative enhancement of its customer service, rapid diffusion and accurate strategy establishment for e-Finance industry in the user side. Through the literature review and factor and reliability analysis, this study selects six diffusion factors such as efficiency of perceived e-Finance, reliability and safety of e-Finance in perceived e-Finance itself's characteristic; confidence, technical factors and the customer service quality of e-Finance system in perception on e-Finance System; inclination to innovation in the personal characteristic. According to result of hypothesis verification by using logistics regression analysis, technical factors and the customer service quality of e-Finance system in perception on e-Finance System and inclination to innovation in the personal characteristic gave statistically positive effect to the diffusion decision at the significant level 0.05 and 0.01. However efficiency of perceived e-Finance, reliability and safety of e-Finance in perceived e-Finance itself's characteristic didn't affect to diffusion decision and confidence of e-Finance system in perception on e-Finance System didn't have any statistical significancy. This study can be used as a basic material for the forward empirical study of diffusion factors in the user side and be able to apply to company and government policy making or embodiment, determination for customer service quality degree of financial institutions. But this study has some limitations like didn't touch satisfaction factors and its effect, only deal domestic customers and didn't use multi-regression analysis.

  • PDF

A study on the developmental plan of Alarm Monitoring Service (기계경비의 발전적 대응방안에 관한 연구)

  • Chung, Tae-Hwang;So, Seung-Young
    • Korean Security Journal
    • /
    • no.22
    • /
    • pp.145-168
    • /
    • 2010
  • Since Alarm Monitoring Service was introduced in Korea in 1981, the market has been increasing and is expected to increase continually. Some factors such as the increase of social security need and the change of safety consciousness, increase of persons who live alone could be affected positively on Alarm Monitoring Service industry. As Alarm Monitoring Service come into wide use, the understanding of electronic security service is spread and consumer's demand is difficult, so consideration about new developmental plan is need to respond to the change actively. Electronic security system is consist of various kinds of element, so every element could do their role equally. Alarm Monitoring Service should satisfy consumer's various needs because it is not necessary commodity, also electronic security device could be easily operated and it's appearance has to have a good design. To solve the false alarm problem, detection sensor's improvement should be considered preferentially and development of new type of sensor that operate dissimilarly to replace former sensor is needed. On the other hand, to settle the matter that occurred by response time, security company could explain the limit on Alarm Monitoring System to consumer honestly and ask for an understanding. If consumer could be joined into security activity by security agent's explanation, better security service would be provided with mutual confidence. To save response time the consideration on the introduction of GIS(Global Information System) is needed rather than GPS(Global Positioning System). Although training program for security agents is important, several benefits for security agents should be considered together. The development of new business model is required for preparation against market stagnation and the development of new commodity to secure consumer for housing service rather than commercial facility service. for the purpose of those, new commodity related to home-network system and video surveillance system could be considered, also new added service with network between security company and consumer for a basis is to be considered.

  • PDF

The Development of On-Line Statistics Program for Radiation Oncology (방사선종양학과 On-line 통계처리프로그램의 개발)

  • Kim Yoon-Jong;Lee Dong-Hoon;Ji Young-Hoon;Lee Dong-Han;Jo Chul-Ku;Kim Mi-Sook;Ru Sung-Rul;Hong Seung-Hong
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.369-380
    • /
    • 2001
  • Purpose : By developing on-line statistics program to record the information of radiation oncology to share the information with internet. It is possible to supply basic reference data for administrative plans to improve radiation oncology. Materials and methods : The information of radiation oncology statistics had been collected by paper forms about 52 hospitals in the past. Now, we can input the data by internet web browsers. The statistics program used windows NT 4.0 operation system, Internal Information Server 4.0 (IIS4.0) as a web server and the Microsoft Access MDB. We used Structured Query Language (SQL), Visual Basic, VBScript and JAVAScript to display the statistics according to years and hospitals. Results : This program shows present conditions about man power, research, therapy machines, technics, brachytherapy, clinic statistics, radiation safety management, institution, quality assurance and radioisotopes in radiation oncology department. The database consists of 38 inputs and 6 outputs windows. Statistical output windows can be increased continuously according to user's need. Conclusion : We have developed statistics program to process all of the data in department of radiation oncology for reference information. Users easily could input the data by internet web browsers and share the information.

  • PDF

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

Standardization of Identification-number for Processed Food in Food-traceability-system (가공식품에 대한 이력추적관리번호 부여체계의 표준화 방안)

  • Choi, Joon-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.194-201
    • /
    • 2012
  • Facing a number of global food-related accidents, the concept and system for food traceability have been designed and introduced in many countries to manage the food-safety risks. To connect and harmonize the various food traceability-information in food traceability system according to the food supply chain, the coding system of identification-number for food-traceability has to be standardized. The GTIN (Global Trade Item Number) barcode system which has been globally standardized and implemented, is reviewed with the mandatory food-labeling regulation in expiration date of processed foods. The integration of GTIN-13 bar-code system for food-traceability is a crucial factor to expand its function in the food-related industrial areas. In this literature, the standard coding system of identification-number for food-traceability is proposed with 20 digit coding number which is combined with GTIN-13 bar-code (13 digit), expiration date (6 digit), and additional classification code (1 digit). This proposed standard coding system for identification-number has a several advantages in application for prohibiting the sale of hazard goods, food-recall, and inquiring food traceability-information. And also, this proposed coding system could enhance the food traceability system by communicating and harmonizing the information with the national network such as UNI-PASS and electronic Tax-invoice system. For the global application, the identification-number for food-traceability needs to be cooperated with the upcoming global standards such as GTIN-128 bar-code and GS1 DataBar.