• Title/Summary/Keyword: Electronic needle

Search Result 173, Processing Time 0.038 seconds

Reliability of Joint Between Solder Bump and Ag-Pd Thick Film Conductor and Interfacial Reaction (솔더범프와 Ag-Pd 후막도체의 접합 신뢰성 및 계면반응)

  • Kim Gyeong Seop;Lee Jong Nam;Yang Taek Jin
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.151-155
    • /
    • 2003
  • The requirements for harsh environment electronic controllers in automotive applications have been steadily becoming more and more stringent. Electronic substrate technologists have been responding to this challenge effectively in an effort to meet the performance, reliability and cost requirements. An effect of the plasma cleaning at the alumina substrate and the IMC layer between $Sn-37wt\%Pb$ solder and Ag-Pd thick film conductor after reflow soldering has been studied. Organic residual carbon layer was removed by the substrate plasma cleaning. So the interfacial adhesive strength was enhanced. As a result of AFM measurement, Ag-Pd conductor pad roughness were increased from 304nm to 330nm. $Cu_6Sn_5$ formed during initial ref]ow process at the interface between TiWN/Cu UBM and solder grew by the succeeding reflow process so the grains had a large diameter and dense interval. A cellular-shaped $Ag_3Sn$ was observed at the interface between Ag-Pd conductor pad and solder. The diameters of the $Ag_3Sn$ grains ranged from about $0.1\~0.6{\mu}m$. And a needle-shaped $Ag_3Sn$ was also observed at the inside of the solder.

  • PDF

A Study on the on Line Monitoring Techniques of the Partial Discharge for Transformer (변압기 부분방전 상시 감시기법에 관한 연구)

  • 권동진;박재준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.1032-1040
    • /
    • 2001
  • In order to apply the partial discharge measuring technique utilizing electrical pulse to the transformer at sites, this paper describes the measuring technique obtaining only the signals due to internal partial discharge in the transformer, but the noises due to external corona which has been a major problem so far. At first, partial discharge and corona noise were simultaneously generated in the model transformer by using needle-plane electrodes and rod-sphere electrodes out of it in a high voltage laboratory, respectively. It was verified that only the partial discharge signals in the transformer could be measured by removing the noise signals from the superposed signals of partial discharges and noises on the grounding wire of the model transformer. By application to a 345kV transformer in service, it was also confirmed that the partial discharge could be on-line monitored by removing the noise signals measured by the inductance sensor on the grounding wire of a 154kV lightning arrester from the superposed signals of internal partial discharge and external corona noise measured by bushing tap coupler of the transformer.

  • PDF

Analysis of Predischarge Processes of $SF_6$ Gas Stressed by lmpulse Voltages under Nonuniform Electric Field (불평등전계중에서 임펄스전압에 대한 $SF_6$ 기체의 전구방전과정의 분석)

  • 이복희;이경옥;이창준;백승권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.1
    • /
    • pp.85-93
    • /
    • 2000
  • In this paper, the predischarge propagation processes of SF\ulcorner gas stressed by impulse voltages under nonuniform electric field perturbed by a needle protrusion are described. The statistical and formative time-lags and the time interval between leader pulses were investigated on the basis of the predischarge current measured in the gas pressure range of 0.1~0.5 MPa. The predischarge current is closely related to the waveform, amplitude and polarity of applied votages, the gas pressure and the gap geometry. Both the positive and negative predischarge processes in nonuniform electric field develop in a regime of stepwise leader propagation leading to electrical breakdown. The mean of the time interval between leader pulses gives about a factor of 10 higher for the negative than for the positive leader current puls-es. According as the gas pressure increases, the statistical time-lag was almost unchangeable, but the formative time-lag was gradually decreased.

  • PDF

A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor (포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구)

  • Ma, Ji-Hoon;Kang, Won-Jong;Lim, Yun-Sok;Choi, Jae-Ok;Chang, Yong-Moo;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF

Discharge characteristics of FFL as the variation of cell structure (셀 구조 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.600-603
    • /
    • 2000
  • Recently, Display devices have become important in the information-oriented society and flat display devices are greatly demanded. Liquid crystal display(LCD) represents one of the most promising devices for large size desk-top monitors, notebook PC and car navigation system. However LCD cannot give forth light itself and must have backlight system. The most popular backlighting system is composed of a lighting-guide plate and CCFL as a lighting source. The number of CCFL must increase up if the area of display is increased. So a new backlighting source with high luminance is needed for large LCDs. In this paper, we proposed a surface discharge FFL with the new electrode structure like the needle shaped electrode as the variation of cell structure to high luminance and low power consumption. In comparison with different electrode structure it has low discharge voltage and current and good optical characteristics. So it has better discharge characteristics than different surface discharge FFL and can be fungible for a backlight as a lighting source in LCDs.

  • PDF

The Aging Measurement of Water Tree Using AgNO$_3$Solution (AgNO$_3$을 이용한 수트리의 실시간 열화계측)

  • Kim, Duck-Keun;Ooh, Soo-Hong;Lee, Jin;Lee, Eun-Hak;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.409-412
    • /
    • 1997
  • The phenomenon of water tree degradation of underground distribution power cables is taking place in polymeric insulation materials under the existence of water and application of electric stress, but water tree is not easy to observe, o water tree features in power cables are shown after cutting and dying with methyleneblue. In previous method, it is impossible to acquire continuous treeing data, and when the insulation material has been cut, the micro crack(water tree) has been damaged. In this paper, to overcome these deflects, the etching method is made use of making needle electrode about 170[${\mu}{\textrm}{m}$] diameter, and AgNO$_3$(silver nitrate) solution is used as liquid electrode to accelerate the growth of water trees. As a result of this study, water tree is observed in real-time with microscope. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuous. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF

PD classification by using ANFIS method (ANFIS 분류기법을 이용한 부분방전원의 분류)

  • Park, Seong-Hee;Yoon, Jae-Hun;Kim, Byong-Chul;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.467-467
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7^*5^*7mm^3$. Distance between needle and plane is 2 mm. Voltages applied to acceleration test are ranged 12 to 15 kV. And distribution characteristic of degraded stage is studied too. By PD detecting and data processing, discharge data was acquired from PD detecting system (Biddle instrument). The system presents statistical distribution of phase resolved. Moreover, the processing time of electrical tree is recorded to know the speed of degradation according to voltage. Finally, it's used PD classification by ANFIS method.

  • PDF

Comparing and Analysis for Classification of PD Source Generated by Electrical Tree (전기트리시 발생하는 부분방전원 분류기법 비교 분석)

  • Yoon, Jae-Hun;Kim, Byong-Chul;Kang, Seong-Hwa;Cheong, Su-Hyeon;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.464-465
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7*5*7\;mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Investigation of Geometrical Properties on Deposition Rate in Cesium Iodine Film (증착속도에 따른 CSI layer의 기하학적 특성 연구)

  • Lee, Kyu-Hong;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Yul;Cho, Sung-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.415-417
    • /
    • 2003
  • CsI 형광체는 X선에 대한 분해능 및 변환효율이 우수한 물질이다. 최근 대면적 평판형 X선 영상검출기의 변환층으로 이용하기 위해 CsI 형광체의 대면적 제조에 대한 연구가 활발히 진행되고 있다. 본 논문은 진공 열증착법을 이용하여 증착속도(3, 3.8, $4.5\;{\mu}m/min$)에 따라 $20\;{\mu}m$ 두께의 CsI 필름을 제조하였고, XRD 및 SEM 분석을 통해 CsI 필름의 기하학적 구조를 조사하였다. 증착된 CsI 필름은 증착속도에 관계없이 복잡한 다결정 구조를 가지며, $3\;{\mu}m/min$의 증착속도에서 약 $1\;{\mu}m$ 크기로 needle-like 한 columnar structure를 가졌다. As results, about 3um/min evaporation rate formed as good geometry characteristics CsI layer.

  • PDF

A Study on the Acoustic Detection of Partial Discharges in Insulation Oil (유중 부분방전의 음향검출에 관한 연구)

  • Kil, Gyung-Suk;Kim, Sung-Wook;Park, Dae-Won;Kim, Sun-Jae;Song, Jae-Man
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.