• Title/Summary/Keyword: Electronic needle

Search Result 173, Processing Time 0.04 seconds

Electric Field distribution Analysis according to radius of curvature in needle electronode (침전극 곡률반경에 따른 XLPE의 전계분포 해석)

  • An, Byung-Chul;Lee, Hyeok-Jin;Kim, Tak-Yong;Byeon, Du-Gyun;Lee, Jong-Yong;Shin, Jong-Yeol;Lee, Su-Won;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.234-235
    • /
    • 2005
  • 본 논문에서는 전력용 케이블에서 초고압으로 사용되고 있는 가교폴리에틸렌 내부(XLPE)에 침투된 침전극의 곡률반경변화에 따른 XLPE의 전계분포를 경계요소법에 의한 3차원 시뮬레이션 프로그램을 통하여 해석하여, 곡률반경이 작을수록 전계가 집중되는 현상을 확인하였다.

  • PDF

A study on Improvement of Electric charge storage characteristics using $Teflon^{(R)}FEP$ film ($Teflon^{(R)}FEP$ film을 사용한 전하보존특성 향상에 관한 연구)

  • Kim, Seong-Jun;Lee, Hyeon-Seok;Kwon, Jeong-Yeol;Kim, Ji-Kyun;Lee, Heon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.539-540
    • /
    • 2006
  • In this paper, We examine that characteristics of formative electret with polymer film and electric charge storage using grid corona discharge. compound polymer of fluorine resin used for material in electret because of high electric charge accumulation, excellent electrical and physical characteristic. All experiments were carried out with circular samples of $Teflon^(R)FEP$ film, 12.5[${\mu}m$] thick. As experiment variables, we used voltage, electrode thickness, discharge electrode gap, and discharge time. According to this variables, we studied on characteristics of formative electret and electric charge storage. Additionally we make a comparative study of the result between the grid corona discharge and needle electrode discharge.

  • PDF

Hydrophobic Properties on RF-sputtered PTFE Films coated on UV-treated Glass Substrates (UV 처리된 유리기판위에 RF-스퍼터된 PTFE 박막들의 발수 특성)

  • Son, Jin-Woon;Youn, Hyon-O;Bae, Kang;Sohn, Sun-Young;Kim, Hwa-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.6-9
    • /
    • 2010
  • Surface properties of polytetrafluoroethylene(PTFE) films fabricated by rf-magnetron sputtering system with UV surface treatment were investigated to increase water contact angle for their hydrophobic property. We found that the surface morphology and water contact angles of PTFE film modified as a function of the UV treatment times using UV-irradiation were influenced. The water contact angle of PTFE film with optimized UV treatment time for 15 minute showed a high hydrophobicity compared with the film without any surface treatment. We thought that it was due to the energy change of PTFE surface with an adhesion improvement to the glass surface as a smoothing a rough surface with needle-shape and/or the enhancement of an interface property as a removing some defects on the surface like a cleaning effect.

A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin (에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

A Study on the changes of electric change induced by Tanchim (彈鍼) manipulation during acupuncture therapy (자침시(刺鍼時) 탄침(彈鍼)의 수기자극(手技刺戟)이 전위변화(電位變化)에 미치는 영향(影響))

  • Kim, Yong-Deug;Kim, Young-Tae;Park, Sung-Sub;Park, Gwi-Jong;Sohn, In-Cheul;Kim, Kyung-Sik
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.1-19
    • /
    • 2004
  • Objectives : To understanding biological mechanism of acupuncture therapy, we have proposed a hypothesis. First of all, there exists electric property in meridian and meridian point. Second of all, energy flowing in meridian is related with electric property. Third of all, there is electronic interaction between the operator who performs acupuncture therapy and the receiver who is given acupuncture therapy. Forth of all, acupuncture effects may depend on the electric capacity which is transferred between the operator and the receiver via acupuncture needle. Methods : Under the hypothesis, we studied the effects of electric change in $ST_{37}(+)\;and\;ST_{39}(-)$ generated by Tanchim (彈鍼) manipulation which was stimulated at $ST_{36}$ point. And compared with data on the changes of electric change from the hand of the operator during acupuncture stimulation. Electric charge induced via acupuncture needle from the operator may be important factor that causes the changes of electric change in meridian and acupoint in the receiver. Therefore we investigated the changes of electric charge induced by the operator using Maclab 400 by the following methods. The one was in stable electric circle condition and the other was in unstable electric circle condition. Results : In this experiments, the changes of electric change from the stimulation type of Tanchim manipulation performed in our lab condition in acupuncture therapy was induced at least three factor, one was the difference of bio-potentials between the operator and the receiver of acupuncture therapy, another was the depth of acupuncture insertion from the skin of the receiver, the other was an electromyogram of the receiver. Conclusion : The data imply that the first factor should make a capacitance current when the operator touched the acupuncture needle which was inserted in the receiver. Therefore, the results suggest that capacitance currents stimulus in electronic view may be important factor in acupuncture therapy between the operator and the receiver of acupuncture therapy.

  • PDF

Study on Control of Refrigerant Flow Rate and Characteristics of Superheat in Evaporator using Electronic Expansion Valve (전자(電子) 팽창밸브를 이용(利用)한 증발기(蒸發器)의 냉매(冷媒) 流量(유량) 제어(制御) 및 과열도(過熱度) 특성(特性)에 관한 연구(硏究))

  • Choi, S.O.;Kim, J.H.;Yang, H.S.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.380-387
    • /
    • 1994
  • An experimental study was performed to investigate the characteristics of refrigerant flow rate control and superheat in an evaporator with an electronic expansion valve(EEV). The EEV used in this study was devised using a needle valve coupled with a stepping motor controlled by a personal computer. A Pill control equation was used to control the superheat of the evaporator and to set the superheat to $5^{\circ}C$. In order to determine an optimum running condition for the system, Pill parameters were varied for the wide range of values. The running condition of an air conditioning system with a PI control was reasonably stable compared with that of the Pill control. Experimental results for the PI control using parameter values, $K_p=1.5$, $T_i=400(sec)$ and $T_s=6(sec)$ show that the superheat reached its target value. When external disturbances were introduced to the system, the superheat target value was reached within about 3 minutes. When the EEV was applied to the air conditioning system driven by an inverter, room temperature control was excellent.

  • PDF

The Decomposition of EMG signals using Template Matiching Method in the frequency domain (주파수 템플릿 정합법을 사용한 EMG 신호 분해)

  • Park, S.H.;Lee, Y.W.;Go, H.W.;Ye, S.Y.;Eom, S.H.;Nam, K.G.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.55-58
    • /
    • 1997
  • In this paper, we study a signal processing method which extracts each MUAP(motor unit action potential) from EMG(Electromyogram) interference pattern or clinical diagnostic purposes. First of all, differential digital filtering is selected or eliminating the spike components of the MUAP's from the background noise. And, the algorithm identifies the spikes over the certanin threshold by template matching in frequency domain. After missing or false firing actor is cut off at the IPI(inter pulse interval) histogram, we averages the MUAP waveforms from the raw signal using the identified spikes as triggers, and Finally, measures their amplitudes, durations, and numbers of phases. Specially, We introduce algorithm performed by template matching in the frequency domain. A typical 3-s signal recorded from the biceps brachii muscle using a conventional needle electrode during a isometric contraction is used. Finally, the method decomposed five simultaneous active MUAP's from original EMG signal.

  • PDF

A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

1-Dimensional Simulation of the Corona Discharge using Fluid Method (유체법을 이용한 코로나 방전의 1차원 수치해석)

  • 이용신;심재학;고광철;강형부
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.172-176
    • /
    • 1997
  • It is likely that the corona discharge appears due to the motion and the multiplication of electron and ion under the nonuniform electric field. Because the motion and the multiplication of electron and ion are the function of electric field, for the simulation of the corona discharge, we have to calculate the electric field, before the calculation of the motion and the multiplication of electron and ion. In this paper, the electric field is calculated on the assumption that the gap between a hyperboloidal needle and a plane is 1-dimension, and the motion and the multiplication of electron and ion are determined by Flux-Corrected Transport method. For this purpose, we solve the electron and ion continuity equation together with Poisson equation. We calculated the current density and the electron and ion density distributions between electrodes as well as electric field distortion due to the space charge assuming that the discharge channel radius is 100${\mu}{\textrm}{m}$. In this simulation, it is found that the current density has one peak as observed by experiment, and electric field distortion is important to the formation and the stability of the corona discharge.

  • PDF

Synthesis and Characterization of Fiberous AlN by Electrospinning (전기방사에 의한 섬유상 질화알루미늄 합성 및 특성 평가)

  • Chun, Seung-Yeop;Hwang, Jin-Ah;Chu, Jae-Uk;Chun, Myoung-Pyo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.7
    • /
    • pp.441-446
    • /
    • 2017
  • Aluminum nitride fibers were synthesized by carbothermal reduction and nitridation of precursor fibers obtained by electrospinning. The starting materials used to synthesize the AlN fibers were $Al(NO_3)_3{\cdot}9H_2O$ and urea. Polyvinylpyrrolidone with increasing viscidity was used as the carbon source to obtain a composite solution. The mixed solution was drawn into a plastic syringe with a stainless steel needle, which was used as the spinneret and connected to a 20 kV power supply. A high voltage was supplied to the solution to facilitate the formation of a dense net of fibers on the collector. The precursor fibers were dried at $100^{\circ}C$ and then heated to $1,400^{\circ}C$ for 1 h in a microwave furnace under $N_2$ gas flow for the carbothermal reduction and nitridation. X-ray diffraction studies indicated that the synthesized fibers consisted of the AlN phase. Field emission scanning electron microscopy studies indicated that the diameter of the calcined fibers was approximately 100 nm.