• Title/Summary/Keyword: Electronic monitoring

Search Result 1,275, Processing Time 0.035 seconds

An Implementation of a Monitoring and Diagnostic System for GIS (GIS의 예측 감시.진단 시스템 구현에 대한 연구)

  • Kim, Youn-Seo;Lee, Hyuck-Jin;Yang, Oh
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.271-273
    • /
    • 2002
  • In this paper, we describe the implementation of a monitoring and diagnostic system for GIS. This system monitors operation status of GIS and transmits data from GIS to host. With this system, an operator can monitor an operating condition and judge the aging of each device, and prevent the failure or breakdown in advance.

  • PDF

On-Line Condition Monitoring and Diagnostics of Distribution Equipment (배전반 설비의 온라인 모니터링 및 진단)

  • Yun, Ju-Ho;Im, Wan-Su;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Analysis of Volatile Compounds using Electronic Nose and its Application in Food Industry (전자코를 이용한 휘발성분의 분석과 식품에의 이용)

  • Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1048-1064
    • /
    • 2005
  • Detection of specific compounds influencing food flavor quality is not easy. Electronic nose, comprised of electronic chemical sensors with partial specificity and appropriate pattern recognition system, is capable of recognizing simple and complex volatiles. It provides fast analysis with simple and straightforward results and is best suited for quality control and process monitoring of flavor in food industry. This review examines application of electronic nose in food analysis with brief explanation of its principle. Characteristics of different sensors and sensor drift. and solutions to related problems are reviewed. Applications of electronic nose in food industry include monitoring of fermentation process and lipid oxidation, prediction of shelf life, identification of irradiated volatile compounds, discrimination of food material origin, and quality control of food and processing by principal component analysis and neural network analysis. Electronic nose could be useful for quality control in food industry when correlating analytical instrumental data with sensory evaluation results.

Implementation of Wireless PGN Analyzer for ISOBUS network

  • Tumenjargal, Enkhbaatar;Badarch, Luubaatar;Lee, Kangsan;Ham, Woonchul;Doopalam, Enkhzul;Togooch, Amartuvshin
    • Smart Media Journal
    • /
    • v.4 no.2
    • /
    • pp.46-54
    • /
    • 2015
  • Communication between ECUs (Electronic Control Units) in agricultural machineries tends to use IS011783 widely, that is PGN (Parameter Group Number) based communication protocol lays on CAN protocol by altering its identifier part. Messages in line are transferred and received between ECUs according to ISO11783 standard. This paper discusses about design of wireless monitoring system. We used an ARM Cortex-M3 microcontroller embedded development board and marvel8686 wireless module. The wireless ISOBUS monitoring system, attached to communication line, reads messages, interpret them, and display them on the screen in easily comprehendible form. It can be used to generate messages and monitor the traffic on physical bus systems. The monitoring system connected to ECUs, monitor and simulate real traffic of communication and functionality of the ECUs. In order to support our work, we have implemented the monitoring tool. The development consists of two parts: GUI of the application and firmware level programming. Hence the monitoring system is attached to the communication line and equipped by Wi-Fi module; farmer/dispatcher in a farm monitors all messages in communication line on personal computer and smart device.

The implementation of the PC-based monitoring device for railway temperature environmental (PC기반의 철도 온도환경에 적합한 모니터링 장치 구현)

  • Bea, Goe-Sung;Son, Ki-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.819-825
    • /
    • 2014
  • The diurnal range of temperature in korea is increasing. We know that the environment has deteriorated through report about railway damage and economic loss caused by climate. In these conditions, Monitoring device for railway must operate to support the operations and maintenance. Therefore, In this paper, COM-based monitoring device implemented using Industrial-Extended electronic components and made, We tested compliance about temperature environment of actual railway. We verified through testing about cold and dry heat of monitoring device. Used components in this product will be able to utilize the development of the railway industry of electronics.

On-line PD Monitoring Using UHF Technique (UHF 가술을 이용한 온라인 PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.115-118
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers. is designed, which has been installed inside the oil tank of a transformer by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Derivation of Real-time Monitoring System for Power Supply System in Metro Substation (도시철도 변전소 전력설비 실시간 모니터링 방안 도출)

  • Jung, Ho-Sung;Park, Young;Oeu, Soo-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.4
    • /
    • pp.333-337
    • /
    • 2010
  • This paper introduces an overall system design of a real-time monitoring system that monitors condition of urban railway AC/DC transformers, disconnecting switches, circuit breakers, regulators, and GIS (gas insulated switchgear). For effective diagnosis of urban railway facilities we developed optimized sensors and application technology. The proposed system is combined with wireless technology, implementing remote real-time monitoring of urban railway facilities. The derived real-time monitoring system for power facilities in urban railway substations will be applied not only to diagnose low voltage DC (direct current) railways but also to diagnose design of small power facilities of skyscrapers and apartments.

Node Monitoring Algorithm with Piecewise Linear Function Approximation for Efficient LDPC Decoding (Node Monitoring 알고리듬과 NP 방법을 사용한 효율적인 LDPC 복호방법)

  • Suh, Hee-Jong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.1
    • /
    • pp.20-26
    • /
    • 2011
  • In this paper, we propose an efficient algorithm for reducing the complexity of LDPC code decoding by using node monitoring (NM) and Piecewise Linear Function Approximation (NP). This NM algorithm is based on a new node-threshold method, and the message passing algorithm. Piecewise linear function approximation is used to reduce the complexity for more. This algorithm was simulated in order to verify its efficiency. Simulation results show that the complexity of our NM algorithm is reduced to about 20%, compared with thoes of well-known method.

A REAL-TIME REMOTE SENSING AND DATA ACQUISITION SYSTEM FOR A NUCLEAR POWER PLANT

  • Kim, Ki-Ho;Hieu, Bui Van;Beak, Seung-Hyun;Choi, Seung-Hwan;Son, Tae-Ha;Kim, Jung-Kuk;Han, Seung-Chul;Jeong, Tai-Kyeong
    • Nuclear Engineering and Technology
    • /
    • v.43 no.2
    • /
    • pp.99-104
    • /
    • 2011
  • A Structure Health Monitoring (SHM) system needs a real-time remote data acquisition system to monitor the status of a structure from anywhere via Internet access. In this paper, we present a data acquisition system that monitors up to 40 Fiber Bragg Grating Sensors remotely in real-time. Using a TCP/IP protocol, users can access information gathered by the sensors from anywhere. An experiment in laboratory conditions has been done to prove the feasibility of our proposed system, which is built in special-purpose monitoring system.

Low-Cost Remote Power-Quality-Failure Monitoring System using Android APP and MCU (안드로이드 앱과 MCU를 이용한 저가형 원격 전원품질이상 감시 시스템)

  • Lim, Ho-Kyoun;Kim, Seo-Hwi;Lee, Seung-Hyeon;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.144-155
    • /
    • 2013
  • This paper presents a low-cost remote power-quality-failure monitoring system (RPMS) using Android App and TI MCU (micro-controller unit), which is appliable to a micro-grid. The designed RPMS testbed consists of smart nodes, a server, and Android APPs. Especially, the C2000-series MCU-based RPMS smart node that is low-cost compared to existing monitoring systems has both a signal processing function for power signal processing and a data transmission function for power-quality monitoring data transmission. The signal processing function implements both a wavelet-based power failure detection algorithm including sag, swell, and interruption, and a FFT-based power failure detection algorithm including harmonics such that reliable and real-time power quality monitoring is guaranteed. The data transmission function implements a low-complexity RPMS transmission protocol and defines a simple data format (msg_Diag) for power monitoring message transmission. We may watch the monitoring data in real time both at a server and Android phone Apps connected to the WiFi network (or WAN). We use RS-232 (or Bluetooth) as the wired (or wireless) communication media between a server and nodes. We program the RPMS power-quality-failure monitoring algorithm using C language in the CCS (Code Composer Studio) 3.3 environment.