• Title/Summary/Keyword: Electronic devices

Search Result 4,580, Processing Time 0.037 seconds

Implementation of Automated Vehicle Electrical and Electronic System based-on Cyber-physical System

  • Song, Younghun;Park, Jeehun;Lee, Kyung-Chang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.1
    • /
    • pp.21-28
    • /
    • 2019
  • As the automated vehicle system evolves, electronic devices and control software installed in vehicles are increasing. Therefore, automated vehicle electrical and electronic system (E/E system) design for ensure system integration, software modularization, system reusability, and scalability at the design stage of the automated vehicle is actively studied. This paper introduces a design methodology for automated vehicle E/E systems that employs by using cyber-physical systems (CPS). An automated forklift system was designed to examine the effectiveness of the proposed methodology. This paper showed that the proposed CPS design methodology enables an effective development of automated E/E control systems. Compare to existing design methodologies, it provides higher reusability of individual modules and an easier way to integrate control system elements such as controllers, sensors, and actuators.

Development of Event-based Object Tracking System (이벤트 기반 물체 추적 시스템 개발)

  • Kim, Sang-Jun;Lee, Hyunkyung;Lee, Seung Ah;Kim, Dae-Yeon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.179-181
    • /
    • 2022
  • 동적 비전 센서(Dynamic Vision Sensor)라고도 알려진 이벤트 카메라는 생체에서 영감을 받은 새로운 시각 센서이다. 고정된 속도로 이미지를 생성하는 기존 카메라와 달리 이벤트 기반 카메라의 픽셀은 독립적이고 비동기적으로 작동한다. 기존 프레임 기반 카메라보다 이벤트 기반 카메라가 움직임을 포착하는데 더 적합하며 모션 블러(Motion Blur)가 없고 시간 해상도가 높다는 이점을 통해 고속카메라로 활용할 수 있다. 본 논문은 이벤트 카메라의 높은 시간 해상도와 동적 범위, 낮은 지연시간, 전력 소비량의 이점을 활용하여 움직이는 물체를 모션 블러 없이 포착하는 이벤트 기반 물체 추적 시스템을 제안한다. 실험을 통해 전체 영상을 포착하는 기존 프레임 기반 카메라에 비해 밝기 변화에 따른 동적 변화만을 추적하는 이벤트 기반 카메라는 모션 블러가 없다는 점을 검증하였다.

  • PDF

Control of Multi-Home Devices Using AI Vision and Generative AI (AI 비전과 생성형 AI 를 이용한 멀티 홈 디바이스 제어)

  • Su-Min Hong;Su-Min Kim;Su-Hee Song;Chae-Yeon Ahn
    • Annual Conference of KIPS
    • /
    • 2023.11a
    • /
    • pp.1037-1038
    • /
    • 2023
  • 기술의 발전으로 인해 스마트 가전제품이 늘어나며 스마트 홈 기술이 주목을 받고 있다. 그러나 이러한 기술은 설정과정의 복잡성으로 사용자들이 쉽게 접근하기 어렵다. 특히 디지털 기기 사용에 익숙하지 않은 사용자들을 스마트 홈 기술로부터 소외시키는 결과를 낳고 있다. 본 논문에서는 사용자 친화적인 스마트 홈 시스템을 제안한다. 사용자의 시선 방향을 추적하여 디바이스를 선택하고 간단한 인터페이스의 컨트롤러로 디바이스를 손쉽게 조작할 수 있도록 한다. 또한, 생성형 인공지능과 RAG 를 결합하여 사용자가 가전제품과 자연스럽게 대화하며 정보를 얻을 수 있는 인터페이스를 제공한다.

Deep Learning-based Extraction of Auger and FCA Coefficients in 850 nm GaAs/AlGaAs Laser Diodes

  • Jung-Tack Yang;Hyewon Han;Woo-Young Choi
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.80-85
    • /
    • 2024
  • Numerical values of the Auger coefficient and the free carrier absorption (FCA) coefficient are extracted by applying deep neural networks (DNNs) to the L-I characteristics of 850 nm GaAs/AlGaAs laser diodes. Two elemental DNNs are used to extract each coefficient sequentially. The fidelity of the extracted values is established through meticulous correlation of L-I characteristics bridging the realms of simulations and measurements. The methodology presented in this paper offers a way to accurately extract the Auger and FCA coefficients, which were traditionally treated as fitting parameters. It is anticipated that this approach will be applicable to other types of opto-electronic devices as well.

High Performance Flexible Inorganic Electronic Systems

  • Park, Gwi-Il;Lee, Geon-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.115-116
    • /
    • 2012
  • The demand for flexible electronic systems such as wearable computers, E-paper, and flexible displays has increased due to their advantages of excellent portability, conformal contact with curved surfaces, light weight, and human friendly interfaces over present rigid electronic systems. This seminar introduces three recent progresses that can extend the application of high performance flexible inorganic electronics. The first part of this seminar will introduce a RRAM with a one transistor-one memristor (1T-1M) arrays on flexible substrates. Flexible memory is an essential part of electronics for data processing, storage, and radio frequency (RF) communication and thus a key element to realize such flexible electronic systems. Although several emerging memory technologies, including resistive switching memory, have been proposed, the cell-to-cell interference issue has to be overcome for flexible and high performance nonvolatile memory applications. The cell-to-cell interference between neighbouring memory cells occurs due to leakage current paths through adjacent low resistance state cells and induces not only unnecessary power consumption but also a misreading problem, a fatal obstacle in memory operation. To fabricate a fully functional flexible memory and prevent these unwanted effects, we integrated high performance flexible single crystal silicon transistors with an amorphous titanium oxide (a-TiO2) based memristor to control the logic state of memory. The $8{\times}8$ NOR type 1T-1M RRAM demonstrated the first random access memory operation on flexible substrates by controlling each memory unit cell independently. The second part of the seminar will discuss the flexible GaN LED on LCP substrates for implantable biosensor. Inorganic III-V light emitting diodes (LEDs) have superior characteristics, such as long-term stability, high efficiency, and strong brightness compared to conventional incandescent lamps and OLED. However, due to the brittle property of bulk inorganic semiconductor materials, III-V LED limits its applications in the field of high performance flexible electronics. This seminar introduces the first flexible and implantable GaN LED on plastic substrates that is transferred from bulk GaN on Si substrates. The superb properties of the flexible GaN thin film in terms of its wide band gap and high efficiency enable the dramatic extension of not only consumer electronic applications but also the biosensing scale. The flexible white LEDs are demonstrated for the feasibility of using a white light source for future flexible BLU devices. Finally a water-resist and a biocompatible PTFE-coated flexible LED biosensor can detect PSA at a detection limit of 1 ng/mL. These results show that the nitride-based flexible LED can be used as the future flexible display technology and a type of implantable LED biosensor for a therapy tool. The final part of this seminar will introduce a highly efficient and printable BaTiO3 thin film nanogenerator on plastic substrates. Energy harvesting technologies converting external biomechanical energy sources (such as heart beat, blood flow, muscle stretching and animal movements) into electrical energy is recently a highly demanding issue in the materials science community. Herein, we describe procedure suitable for generating and printing a lead-free microstructured BaTiO3 thin film nanogenerator on plastic substrates to overcome limitations appeared in conventional flexible ferroelectric devices. Flexible BaTiO3 thin film nanogenerator was fabricated and the piezoelectric properties and mechanically stability of ferroelectric devices were characterized. From the results, we demonstrate the highly efficient and stable performance of BaTiO3 thin film nanogenerator.

  • PDF

erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

Development of a Novel Noncontact ECG Electrode by MEMS Fabrication Process

  • Mathias, Dakurah Naangmenkpeong;Park, Jaesoon;Kim, Eungbo;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.3
    • /
    • pp.150-154
    • /
    • 2016
  • Contact electrodes pose threats like inflammation, metal poisoning, and allergic reaction to the user during long term ECG procedure. Therefore, we present a novel noncontact electrocardiographic electrode designed through microelectromechanical systems (MEMS) process. The proposed ECG electrode consists of small inner and large outer circular copper plates separated by thin insulator. The inner plate enables capacitive transduction of bio-potential variations on a subject’s chest into a voltage that can be processed by a signal processing board, whereas the outer plate shields the inner plate from environmental electromagnetic noise. The electrode lead wires are also coaxially designed to prevent cables from coupling to ground or electronic devices. A prototype ECG electrode has an area of about 2.324 cm2, is very flexible and does not require power to operate. The prototype ECG electrode could measure ECG at about 500 um distance from the subject’s chest.

Effect of heat treatment in $HfO_2$ as charge trap with engineered tunnel barrier for nonvolatile memory (비휘발성 메모리 적용을 위한 $SiO_2/Si_3N_4/SiO_2$ 다층 유전막과 $HfO_2$ 전하저장층 구조에서의 열처리 효과)

  • Park, Goon-Ho;Kim, Kwan-Su;Jung, Myung-Ho;Jung, Jong-Wan;Chung, Hong-Bay;Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.24-25
    • /
    • 2008
  • The effect of heat treatment in $HfO_2$ as charge trap with $SiO_2/Si_3N_4/SiO_2$ as tunnel oxide layer in capacitors has been investigated. Rapid thermal annealing (RTA) were carried out at the temperature range of 600 - $900^{\circ}C$. It is found that all devices carried out heat treatment have large threshold voltage shift Especially, device performed heat treatment at $900^{\circ}C$ has been confirmed the largest memory window. Also, Threshold voltage shift of device used conventional $SiO_2$ as tunnel oxide layer was smaller than that with $SiO_2/Si_3N_4/SiO_2$.

  • PDF

Post-annealing Effect of NiO Thin Film Grown by RF Sputtering System on 4H-SiC Substrate (4H-SiC 기판 위에 RF Sputter로 증착된 NiO 박막의 후열처리 효과)

  • Soo-Young Moon;Min-Yeong Kim;Dong-Wook Byun;Geon-Hee Lee;Sang-Mo Koo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.2
    • /
    • pp.170-174
    • /
    • 2023
  • Nickel oxide is a nonstoichiometric transparent conductive oxide with p-type conductivity, a wide-band energy gap of 3.4~4.0 eV, and excellent chemical stability, making it a very important candidate as a material for bipolar devices. P-type conductivity in Transparent Conductive Oxides (TCO) is controlled by the oxygen vacancy concentration. During the TCO film deposition process, additional oxygen diffusing into the NiO structure causes the formation of Ni 3p ions and Ni vacancies. This eventually affects the hole concentration of the p-type oxide thin film. In this work, the surface morphology and the electrical characteristics were confirmed in accordance with the annealing atmosphere of the nickel oxide thin film.

A Study on the Actual Use of Mobile Electronic Notification Service (모바일 전자고지서비스의 사용실태에 대한 조사 연구)

  • Kim, Jong-Bae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.167-180
    • /
    • 2021
  • Due to the development of IT technology and the spread of infectious diseases, online non-face-to-face services are rapidly expanding. In particular, the information delivery process is also changing from the past postal branch-based to an information delivery system using mobile devices. This change is due to the change from the information delivery using the telephone line to the information delivery system using the Internet. Mobile notification service is a service that sends electronic notices to mobile devices held by users to deliver information and is validated for delivery, which has the advantage of reducing the benefits of unnecessary mail production, exposure to personal information, and misdelivery. However, user identification information must be provided to operators that provide mobile electronic notification services. In this paper, the current state of use of the mobile electronic notice service, which has been in effect since 2019, is investigated and analyzed, and the current mobile electronic notice service is to be safely provided and to take appropriate protection measures for personal information. In providing the mobile electronic notification service to users, it is possible to identify the service standards required by the sending agency, and based on this, prepare the technical standards for the mobile electronic notification service that the sending agency must comply with in advance and use it for the mobile electronic notification service.