• 제목/요약/키워드: Electronic cooling

검색결과 461건 처리시간 0.027초

Cooling System Design in Power Electronic

  • Kim Chan-Ki;Rhew Hong-Woo;Kim Yoon-Ho;Holtz J.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.520-523
    • /
    • 2003
  • In this paper, heatsink design for high power converter is presented. There are many ways of designing heatsink, but air cooling is by far the most used and much more practical than any of the other methods. In this paper, the practical methods of cooling which include the method to reduce a noise and a vibration due to a fan and the method to design a gap resistance and a contact resistance due to mounting force between thyristor and heatsink is proposed. Finally, simulation and experimental results are described to verify validity of the proposed method.

  • PDF

LED 조명 방열 환경에서 진동형 히트파이프의 작동 특성 (Operational Characteristics of Pulsating Heat Pipes for the Application to the Heat Dissipation of LED Lighting)

  • 방광현;김형탁;박해균
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.830-836
    • /
    • 2012
  • An efficient cooling system is essential for the electronic packaging such as a high-luminance LED lighting. A special heat transport technology, Pulsating Heat Pipe (PHP), can be applied to the cooling of LED lighting. In this paper, the operational characteristics of the PHP in the imposed thermal boundary conditions of LED lighting were experimentally investigated. The experimental PHP was made of copper tubes of internal diameter of 2.1 mm. The working fluids of ethanol, FC-72, water, acetone and R-123 were chosen for comparison. The results showed that an optimum range of charging ratio exists for high cooling performance; 50% for most of the fluids. Among the five working fluids, water showed the highest heat transfer rate of 260 W. Two distinguished characteristics of pulsating direction were identified. It is also identified that high vapor pressure gradient is one of key parameters for better heat transfer performance.

데이터센터의 공조효율 향상을 위한 공조파티션시스템 성능평가에 관한 연구 (Evaluation of Aisle Partition System's Thermal Performance in Large Data Centers for Superior Cooling Efficiency)

  • 조진균;정차수;김병선
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.205-212
    • /
    • 2010
  • In a typical data center, large numbers of IT sever racks are arranged multiple rows. IT environments, in which extensive electronic hardware is air-cooled, cooling system inefficiencies result when heated exhaust air from equipment prematurely mixes with chilled coolant air before it is used for cooling. Mixing of chilled air before its use with heated exhaust air results in significant cooling inefficiencies in many systems. Over temperatures may not only harm expensive electronic equipment but also interrupt critical and revenue generating services. Cool shield is a cost effective aisle partition system to contain the air in cold aisles and hot aisles of an IT server room. This paper focuses on the use of performance metrics for analyzing aisle partition system in data centers.

계통연계형 태양광 인버터의 냉각장치 위치에 따른 주요발열부 온도특성 해석 (Temperature Characteristics Analysis of Major Heating Region According to Cooling Device Location of Grid-Connected Photovoltaic Inverter)

  • 김민석;김용재
    • 한국전자통신학회논문지
    • /
    • 제9권7호
    • /
    • pp.799-804
    • /
    • 2014
  • 무한정한 발전자원과 무공해성 등의 장점을 가진 태양광 발전 시스템은 직류전력을 생산하기 때문에 계통의 연계송전이 가능한 교류전력으로 변환시켜주기 위해서는 태양광 인버터의 사용이 필요하다. 외부에 옥외형 구조로 노출되어 설치되는 소용량의 태양광 인버터는 태양이 강하게 내리쬐는 낮 시간 및 여름철과 같이 외부 환경의 온도가 상승함에 따라 에너지 손실이 발생하고 효율이 감소하게 된다. 태양광 발전 산업의 범위가 확대됨에 따라 태양광 인버터 또한, 상당한 에너지 손실 문제를 야기하므로 이에 따른 대책이 필요하다. 따라서 본 논문에서는 온도조건에 구애받지 않도록 태양광 인버터 외함에 열전소자를 부착한 냉각장치를 설치하고 냉각효과의 극대화를 위해 두 개의 냉각장치를 사용하여 위치 조절에 따른 냉각효과를 비교분석하고자 한다.

RF 스퍼터링 법에 의한 ZnO 박막의 결정성과 기판의 냉각속도 (The crystalline characteristics of ZnO deposited on various cooling rates by RF sputter)

  • 박성현;이능헌;지승한;전석환;이상훈;추순남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.257-258
    • /
    • 2006
  • ZnO thin films were prepared by RF magnetron sputter deposition on p-Si(100) wafer with various cooling rates of substrate temperature such as the substrates were pre-heated to $400^{\circ}C$ before the deposition and then cooled down naturally or slowly to $300^{\circ}C$, $200^{\circ}C$, $100^{\circ}C$, and R.T., by the temperature controller during the deposition. The crystall me and micro-structural characteristics of the films were investigated by XRD and SEM ZnO films which cooled down naturally or slowly by temperature controller during deposition, especially the film were deposited with cooling down from $400^{\circ}C$ to $200^{\circ}C$ slowly, showed the most outstanding c-axis preferred orientation.

  • PDF

Electronics Cooling Using the Porous Metallic Materials

  • Lucaci, Mariana;Orban, Radu L.;Lungu, Magdalena;Enescu, Elena;Gavriliu, Stefania
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.315-316
    • /
    • 2006
  • The paper presents some results regarding the obtaining of some copper heat pipes with a porous copper internal layer for electronic components cooling. The heat pipes were realized by sintering of spherical copper powders of $90{\div}125\;{\mu}m$ size directly on the internal side of a copper pipe of 18 mm in diameter. The obtained pipes were then brazed in order to obtain a heat pipe of 0.5 m in length. After that, the heat pipe was sealed and filled with a small quantity of distilled water as working fluid. To establish the total heat transport coefficient and the thermal flow transferred at the evaporator, some external devices were realized to allow the heating of the evaporator and the cooling of the condenser. Water heat pipes are explored in the intermediate temperature range of 303 up to 500 K. Test data are reported for copper water heat pipe, which was tested under different orientations. The obtained results show that the water heat pipe has a good thermal transfer performance in the temperatures range between 345 and 463 K.

  • PDF

편조형 윅을 갖는 소형 히트파이프의 냉각특성에 관한 연구 (A Study on Cooling Characteristics of Miniature Heat Pipes with Woven-Wired Wick)

  • 문석환;김광수;최춘기
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.227-234
    • /
    • 2000
  • An experimental study was performed for understanding the limiting power and heat transfer characteristics of an MHP having the diameter of 3 or 4 mm which could be applied to cooling of miniature electronic equipment such as the notebook PC CPU etc. The experimental parameters which are inclination, structure of the wick, the length of the condenser and the total heat pipe were considered. The MHP with a woven-wired wick has the advantages of the improvement in capillary limit, the effective attachment tightly toward wall and the convenience in construction of wick. Cooling performance of the present MHP was compared with that of MHP with grooved, fine fiber and sintered type wick which were applied by existing enterprises. With respect to the inclination of$ -5^{\circ}$ , an MHP having the diameter of 3 or 4 mm shows the limiting power of 6~14 W. Therefore, it is expected that the MHP of the present study has sufficient applicability of cooling of notebook PC of which the amount of heat generated is about 12 W.

  • PDF

액체질소중에 있어서 아크방전 및 방사 전자파의 특성에 관한 연구 (A study on the characteristics of arc discharge and radiated electromagnetic wave in liquid nitrogen)

  • 신동화;박광서;주재현;최병주;김기채;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1669-1671
    • /
    • 1997
  • Liquid nitrogen has many adventages. It is cheaper than other cooling medium. It is easy to obtain high purity. It's utilized with easy. In future, liquid nitrogen is able to be accepted cooling medium for the superconducting and cryogenic applicated equipments. Cryogenic liquid may be atmospheric pressure state because thermoinsulation is ineffective, airtight decreasing by long time using and bubble occured by flowing current. If it is to be atmospheric pressure state, the electrical insulation strength is dropped and processed partial discharge, finally breakdown. Processing of breakdown has anticipated by measuring radiated-electromagnetic wave which is happened in time of breakdown. There is a measurement of radiated electromagnetic wave as a method that proceeding breakdown is anticipated. In this paper, radiated electromagnetic wave was measured in arc discharge by above conditions as a basic experiment.

  • PDF

운전조건 변화에 따른 이산화탄소 열펌프의 냉난방 성능특성 비교 (Cooling and Heating Performances of a CO2 Heat Pump with the Variations of Operating Conditions)

  • 조홍현;백창현;이응찬;강훈;김용찬
    • 대한기계학회논문집B
    • /
    • 제32권6호
    • /
    • pp.454-462
    • /
    • 2008
  • Since operating conditions are significantly different for heating and cooling mode operations in a $CO_2$ heat pump system, it is difficult to optimize the performance of the $CO_2$ cycle. In addition, the performance of a $CO_2$ heat pump is very sensitive to outdoor temperature and gascooler pressure. In this study, the cooling and heating performances of a variable speed $CO_2$ heat pump with a twin-rotary compressor were measured and analyzed with the variations of EEV opening and compressor frequency. As a result, the cooling and heating COPs were 2.3 and 3.0, respectively, when the EEV opening was 22%. When the optimal EEV openings for heating and cooling were 28% and 16%, the cooling and heating COPs increased by 3.3% and 3.9%, respectively, over the COPs at the EEV opening of 22%. Beside, the heating performance was more sensitive to EEV opening than the cooling performance. As the compressor speed decreased by 5 Hz, the cooling COP increased by 2%, while the heating COP decreased by 8%.