DOI QR코드

DOI QR Code

Cooling and Heating Performances of a CO2 Heat Pump with the Variations of Operating Conditions

운전조건 변화에 따른 이산화탄소 열펌프의 냉난방 성능특성 비교

  • 조홍현 (미국국립표준연구원) ;
  • 백창현 (고려대학교 기계공학과 대학원) ;
  • 이응찬 (고려대학교 기계공학과 대학원) ;
  • 강훈 (고려대학교 기계공학과 대학원) ;
  • 김용찬 (고려대학교 기계공학과 대학원)
  • Published : 2008.06.01

Abstract

Since operating conditions are significantly different for heating and cooling mode operations in a $CO_2$ heat pump system, it is difficult to optimize the performance of the $CO_2$ cycle. In addition, the performance of a $CO_2$ heat pump is very sensitive to outdoor temperature and gascooler pressure. In this study, the cooling and heating performances of a variable speed $CO_2$ heat pump with a twin-rotary compressor were measured and analyzed with the variations of EEV opening and compressor frequency. As a result, the cooling and heating COPs were 2.3 and 3.0, respectively, when the EEV opening was 22%. When the optimal EEV openings for heating and cooling were 28% and 16%, the cooling and heating COPs increased by 3.3% and 3.9%, respectively, over the COPs at the EEV opening of 22%. Beside, the heating performance was more sensitive to EEV opening than the cooling performance. As the compressor speed decreased by 5 Hz, the cooling COP increased by 2%, while the heating COP decreased by 8%.

Keywords

References

  1. Neksa, P., Rekstad, H., Zakeri, R., Schiefloe, P., 1998, “$Co_2$-Heat Pump Water Heater: Characteristics, System Design and Experimental Results,” Int. Journal of Refrigeration, Vol. 21, No. 3. pp. 172-179 https://doi.org/10.1016/S0140-7007(98)00017-6
  2. Hrnjak, P., Richeter, M., Song, S., Yin, J., Kim, M., Bullard, C., 2000, “Transcritical $Co_2$ Heat Pump for Residential Application,” 4Th Iir-Gustav Lorentzen Natural Working Fluids Conference At Purdue, pp. 9-16
  3. Sarkar J., Bhattacharyya S., Gopal M., 2004, “Optimization of a Transcritical $Co_2$ Cycle for Simultaneous Cooling and Heating Applications,” Int. Journal of Refrigeration, Vol. 27, No. 8, pp. 830-838 https://doi.org/10.1016/j.ijrefrig.2004.03.006
  4. Sarkar J., Bhattacharyya S., Gopal M., 2006, “Simulation of a Transcritical $Co_2$ Heat Pump Cycle for Simultaneous Cooling and Heating Applications,” Int. Journal of Refrigeration, Vol. 29, No.5, pp. 735-743 https://doi.org/10.1016/j.ijrefrig.2005.12.006
  5. Chen, Y., Gu, J., 2005, "The Optimum High Pressure for $Co_2$ Transcritical Refrigeration Systems with Internal Heat Exchangers," Int. Journal of Refrigeration, Vol. 28, No. 8, pp. 1238-1249 https://doi.org/10.1016/j.ijrefrig.2005.08.009
  6. Stene J., 2005, "Residential $Co_2$ Heat Pump System for Combined Space Heating and Hot Water Heating," Int. Journal of Refrigeration, Vol. 28, No. 8, pp. 1259-1265 https://doi.org/10.1016/j.ijrefrig.2005.07.006
  7. Richter M., Song S., Yin J., Kim M., Bullard C., Hrnjak, P., 2003, “Experimental Results of Transcritical $Co_2$ Heat Pump for Residential Application,” Energy, Vol. 28, pp. 1005-1019 https://doi.org/10.1016/S0360-5442(03)00065-3
  8. Ashrae, 2005, “Engineering Analysis Of Experi mental Data,” Ashrae Guideline 2
  9. Cho, H., Ryu, C., Kim, Y., 2007, “Cooling Performance of a Variable Speed $Co_2$ Cycle with an Electronic Expansion Valve and Internal Heat Exchanger,” Int. Journal of Refrigeration, Vol. 30, No.4, pp. 664-671 https://doi.org/10.1016/j.ijrefrig.2006.10.004
  10. Ashrae, 1983, “Methods of Testing For Seasonal Efficiency of Unitary Air-Conditioner and Heat Pumps,” Ashrae Standard 116
  11. Cho, H., Lee, H., Jang, Y., Kim, H., 2007, “Experimental Study on the Heating Performance of a Variable Speed $Co_2$ Heat Pump with a Variation of Operating Conditions,” Ksme Korean Journal(B), Vol. 31, No.8, pp. 694-701 https://doi.org/10.3795/KSME-B.2007.31.8.694