• 제목/요약/키워드: Electronic Medical Device

검색결과 211건 처리시간 0.048초

DACUM 법을 활용한 유비쿼터스 의료전자기기 전문가의 직무분석 (Job Analysis of Ubiquitous Medical Electronic Device Export by the Method of DACUM)

  • 조동헌;구경완
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1192-1197
    • /
    • 2013
  • In this paper Ubiquitous Medical Electronic Device Export was defined, and it's job analysis. The authors have been defined the job and classified duties and tasks of Ubiquitous Medical Electronic Device Export. To fine what is the most efficient task for Ubiquitous Medical Electronic Device Export, we have been investigated the levels of importance, difficulty, frequency and entry in each task. A DACUM committee is composed of total 12 members, which are one facilitator, 10 panel members, one coordinator & recorder to analyze the job of Ubiquitous Medical Electronic Device Export. Following is the result of this study. First, The process began with the identification of a job title and definition of Ubiquitous Medical Electronic Device Export. Second, a job model of Ubiquitous Medical Electronic Device Export is constructed based on the results of DACUM job analysis. 5 duties and 33 tasks are analyzed. Third, occupational specification was drawn up in consultation with SME council. Fourth, duty specification was drawn up in consultation. 33 tasks that are essential in entry level of occupation are identified. Fifth, task specification was drawn up in consultation. Detail task component which include skill, materials, knowledge, equipment, achievement level and tool was specified in task specification.

전자의료기기용 소프트웨어의 신뢰성 평가 방법 (Reliability Evaluation Method of Software for Electronic Medical Devices)

  • 박순옥;양해술
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.758-767
    • /
    • 2007
  • 오늘날 의료기기는 내장된 소프트웨어에 의해 제어되는 전자 의료기기의 형태로 급격하게 발전하고 있다. 따라서 전자 의료기기의 품질은 내장된 의료용 소프트웨어의 품질에 의해 크게 좌우될 수밖에 없다. 특히, 의료기기가 인간의 생명과 밀접하게 연관되어 있다는 점을 고려할 때, 프로그램 가능한 전자 의료기기의 품질 측면에서도 신뢰성 측면을 특히 고려한 평가 방법이 연구되어야 할 것으로 생각된다. 본 논문에서는 소프트웨어 제품평가에 관련된 국제표준인 ISO/IEC 9126과 ISO/IEC 12119를 기반으로 하여 국내의 프로그램 가능한 전자 의료기기의 특성을 고려하여 신뢰성에 대한 평가를 위한 방법을 구축하고 아울러 신뢰성 평가 방법인 FMEA 기법을 적용할 수 있는 체계를 구축하였다.

  • PDF

한국 의료기기 산업의 역사와 국제 경쟁력 고찰 (A Study on the History of the Korean Medical Device Industry and its Global Competitiveness)

  • 염호준;정현우;박상수
    • 문화기술의 융합
    • /
    • 제8권5호
    • /
    • pp.1-7
    • /
    • 2022
  • 한국의 의료기기 산업은 1995년부터 시작된 G7 의료공학기술개발사업으로 본격적인 성장과 발전의 기틀을 마련하였으며 2020년 한국 의료기기 생산실적은 2001년에 비하여 8.52배, 수출 실적은 13.94배 성장하였다. 의료기기 국산화 개발 초기에 초음파 의료기기 등 전자 의료기기의 개발이 활발하였던 것과 비교하여 2020년에는 체외진단시약과 치과용 임플랜트의 생산 및 수출 실적이 상위권을 차지하고 있다. 그러나 한국 의료기기 시장에서 수입 의료기기가 차지하는 비중은 60-70%에서 큰 변화가 없는데 이는 한국의 의료기기 산업이 중저가 의료기기를 생산 수출하고, 기술집약적이고 자본집약적인 고가 의료기기는 주로 수입에 의존하고 있기 때문이다. 본 논문에서는 한국과 세계시장의 주요 의료기기 회사들의 생산 품목을 비교하여 한국 의료기기 산업의 세계 시장 진출에 대한 전략을 제시하고자 한다.

현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 - (Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 -)

  • 김선칠
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가 (Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System)

  • 김영표;천민우;박용필
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

A Comparison between Portal Dosimetry and Mobius3D Results for Patient-Specific Quality Assurance in Radiotherapy

  • Kim, Sung Yeop;Park, Jaehyeon;Park, Jae Won;Yea, Ji Woon;Oh, Se An
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.107-115
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the clinical quality assurance results of portal dosimetry using an electronic portal imaging device, a method that is extensively used for patient-specific quality assurance, and the newly released Mobius3D for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: This retrospective study includes data from 122 patients who underwent IMRT and VMAT on the Novalis Tx and VitalBeam linear accelerators between April and June 2020. We used a paired t-test to compare portal dosimetry using an electronic portal imaging device and the average gamma passing rates of MobiusFX using log files regenerated after patient treatment. Results: The average gamma passing rates of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm) were 99.43%±1.02% and 99.32%±1.87% in VitalBeam and 97.53%±3.34% and 96.45%±13.94% in Novalis Tx, respectively. Comparison of the gamma passing rate results of portal dosimetry (3%/3 mm) and MobiusFX (5%/3 mm as per the manufacturer's manual) does not show any statistically significant difference. Conclusions: Log file-based patient-specific quality assurance, including independent dose calculation, can be appropriately used in clinical practice as a second-check dosimetry, and it is considered comparable with primary quality assurance such as portal dosimetry.

생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리 (Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device)

  • 이한욱;이주원;정원근;김성후;이건기
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

이식형 전자의료기 연구동향과 기술개발의 과제 (Research Trends and Challenges in Technology Development of Medical Electronic Implant Devices)

  • 조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.415-430
    • /
    • 2008
  • The technologies in medical electronic implant(MEI) devices are developing rapidly, and already, there are various kinds of the MEI devices in the current medical equipments market. Recently, the global market scale of MEI devices have been increased about 13% year by year, and the import amount of MEI devices in Korea is increasing rapidly. In the near future, the demands of MEI devices will be magnificently increasing by the continuous development of the biomedical electronics devices which coupled with neural, brain and other organs will bring us to tremendous effects, such as providing new therapeutic solutions to patients, extension and saving human life, and an important clue of medical development. However, the investment of the research and the activity of developments in this field are still very weak in the Korea. Consequently, this paper introduces about the research trends of MEI devices, and technological problems those must be solved, and then concludes with the suggestions in order to be the leading country in this field.

유기박막의 파괴전압과 전기특성 (Breakdown Voltage and Electrical Characteristics of Organic Thin Film)

  • 송진원;강용철;김형곤;이우선;정헌상;장희동;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1497-1499
    • /
    • 2000
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 30 [mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto y-type silicon wafer as y-type film. In processing of a device manufacture. we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/arachidic acid/Al. the number of accumulated layers are 9$\sim$21. Also. we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF