• 제목/요약/키워드: Electronic Governor

검색결과 16건 처리시간 0.023초

전자식 가버너를 이용한 디젤 자동차의 헌팅억제 제어에 관한 연구 (A Study on Suppressed Hunting of Diesel Engine Truck Using Electronic Governor)

  • 홍순일;김남식
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.68-73
    • /
    • 1998
  • The propulsion diesel engine have been widely applied with a mechanical governor to control the truck speed for a long time. But it was recently very difficult for mechanical governor to control the speed of long stock and diesel engine of truck because of hunting by dead time between fuel injection and power output. This study is aimed to configure the modeling for performance simulation regarding to diesel truck operation which could be suppressed for hunting. The modeling have been made on the base of dynamic characteristic such as electronic governor, injection of fuel system and operating states of diesel engine truck. Real model system have been introduced for deciding reacting parameters and for the comparison of resulting performance in simulation. In results of simulation, we obtained items which diesel truck drives for suppressed hunting.

  • PDF

대용량 발전소 재열재생 증기터빈 제어알고리즘에 관한 고찰 (A Study on Turbine Control Algorithms for Large Steam Turbine in a Power Plant)

  • 최인규;정창기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1665-1666
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Therefore after the steam turbine reaches its rated speed and the generator gets into parallel operation with power grid, the electrical power can be increased by turbine controller or governor. The first governor was invented by James Watts for the steam engine to be maintained at a constant speed. The first governor by him was mechanical type with fly balls. The electrical type governor was created due to the progress of electronic devices such as operational amplifiers or integrated circuits. and Today digital electronic type of governor is being widely used in most prime movers.

  • PDF

조속기 시험 시스템의 자동화 (Automation of Governor Performance Test System)

  • 이일영;김지웅;강만곤
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.155-161
    • /
    • 2005
  • Governors control the revolution speed of heat engines such as diesel engines, steam turbines and gas turbines. Precise and prompt tests for the control performances of governors are essential both in governors' manufacturing processes and in governors' maintenance processes. In the conventional governor test systems controlled by analog type electronic controllers, the incorporation of heat engine's dynamics to the test system have been considered very difficult to realize. This study suggests a new governor test system controlled by a digital controller using a personal computer. The application of the digital controller to the test system instead of the analog type electronic controller have brought about the following advancements; (1) heat engine's dynamics could be implemented easily in the test system, (2) automatic test data acquisition both in steady state and in transient state enables us to save test time and to enhance the reliability of the tests.

  • PDF

전자유압식 Governor의 개발 :화력발전소증기 turbine에 있어서의 해외논초 (Development on Governor of electronic oil pressure type for stt:am turbine of thermal power plant)

  • 대한전기학회
    • 전기의세계
    • /
    • 제17권2호
    • /
    • pp.35-37
    • /
    • 1968
  • 증기 Turbine plant의 제어방식은 점점 더 복잡하게 고도화하고 있으며 원심 또는 유압조속기등 Lever와 유압기구의 조합으로 구성된 기계유압식 Governor 대신에 전자유압식 Governor(Electro-Hydraulic Governor, EHG 일반적으로 광의의 의미로는 전자유압식제어장치 Electro-Hydraulic Control System이라함)의 개발에 주력하고 있으며 본보고서는 이에 대한 시험결과를 기술한 것이다. 본보고서는 산업용(자가발전용) 증기 Turbine의 전자유압식 Governor에 관한 것으로서 기계유압식에서의 복잡한 Lever 기구, Relay 장치등 기계부분의 전자유압화와 고압제어유의 채용및 이에 따르는 각부분의 Module화, Solid State화 및 소형 Unit화에 의하여 취급및 보수가 용이한 고성능의 제어장치를 개발하게 되었다. 특히 미국의 GE사에서 이에 대한 개발이 앞서 있으며 현재 100MW까지 약 30대가 실용화되고 있다고 한다. (이글은 일본화력발전지 1968년 1월 제136호에서 발췌한 글이다.)

  • PDF

200MW급 가스터빈 조속기 응답특성에 대한 연구 (A Study on the Response Characteristics of 200MW Gas Turbine Governor System)

  • 한영복;남강현;김성호
    • 한국전자통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.625-632
    • /
    • 2022
  • 국내 전력계통에 부하추종운전 중인 가스터빈 발전기들은 정격 주파수 유지에 큰 역할을 하고 있지만 종종 주파수 제어가 불량한 경우도 발생한다. 이에 가스터빈 속도제어 장치인 조속기의 제어 특성을 살펴보고 고장 유형을 분석한 후 사안 별로 대책을 제시하였다. 그리고, 가스터빈은 연료제어의 빠르기에 따라 주파수 회복에는 도움을 되지만 연소실 온도가 급격하게 변동하고 연소진동이 발생하는 등 안정운전을 저해하는 요소로 작용하기도 한다는 것을 조속기 응동시험을 통해 확인하였다. 따라서, 안정적인 전력품질을 유지하기 위해서는 철저한 설비관리를 수행하고 비례 적분 미분 제어방식에 4차산업의 핵심분야인 기계학습 알고리즘이 융합된 조속기 제어방식의 연구 필요성이 대두되었다.

국내 계통 최대부하변동에 대한 BESS 및 조속기 특성 비교 분석 (Comparative Analysis of BESS and Governor Responses for Maximum Load Variations in Korea Power System)

  • 강한구;전영환
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.194-198
    • /
    • 2018
  • The government established the 8th national energy plan that electricity energy from renewables in 2030 will be 20%. The frequency stability problem is one of the key issues to overcome for accomplishing the energy plan. Frequency quality deteriorates due to short term variations of renewables output. Battery energy storage system(BESS) is considered as a good alternative to improve the frequency quality due to its quick response. In this paper, we examined the effectiveness of BESS against the conventional governor properties.

Introduction of Generator Unit Controller and Its Tuning for Automatic Generation Control in Korean Energy Management System (K-EMS)

  • Park, Min-Su;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Automatic generation control (AGC) is an important function for load frequency control, which is being implemented in Energy Management System (EMS). A key feature of AGC is to back up governors to enhance the performance of frequency control. The governor regulates system frequency in several to ten seconds, while the droop control concept results in steady-state control error. AGC is a supplementary tool for compensation of the steady-state error caused by the droop setting of the governors. As the AGC target is delivered to each generator as an open loop control target, the generator output is not guaranteed to follow the AGC target. In this paper, we introduce generating unit controller (GUC) control block, which has the purpose of enabling the generator output to track the AGC target while maintaining the governor performance. We also address the tuning methods of GUC for better performance of AGC in the Korea Energy Management System (K-EMS).

Augmented Reality based Low Power Consuming Smartphone Control Scheme

  • Chung, Jong-Moon;Ha, Taeyoung;Jo, Sung-Woong;Kyong, Taehyun;Park, So-Yun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권10호
    • /
    • pp.5168-5181
    • /
    • 2017
  • The popularity of augmented reality (AR) applications and games are in high demand. Currently, the best common platform to implement AR services is on a smartphone, as online games, navigators, personal assistants, travel guides are among the most popular applications of smartphones. However, the power consumption of an AR application is extremely high, and therefore, highly adaptable and dynamic low power control schemes must be used. Dynamic voltage and frequency scaling (DVFS) schemes are widely used in smartphones to minimize the energy consumption by controlling the device's operational frequency and voltage. DVFS schemes can sometimes lead to longer response times, which can result in a significant problem for AR applications. In this paper, an AR response time monitor is used to observe the time interval between the AR image input and device's reaction time, in order to enable improved operational frequency and AR application process priority control. Based on the proposed response time monitor and the characteristics of the Linux kernel's completely fair scheduler (CFS) (which is the default scheduler of Android based smartphones), a response time step control (RSC) scheme is proposed which adaptively adjusts the CPU frequency and interactive application's priority. The experimental results show that RSC can reduce the energy consumption up to 10.41% compared to the ondemand governor while reliably satisfying the response time performance limit of interactive applications on a smartphone.

속응자원의 국내 및 북미 ISO/RTO 주파수조정예비력 서비스 제공에 따른 보상규칙 비교 분석 (Comparison of Compensation Rules for Fast Responding Resources Providing Frequency Regulation Service in Domestic and North American ISO/RTO Power Electricity Market)

  • 박대현;박용기;박종배;김발호;노재형
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.617-625
    • /
    • 2018
  • Since FERC order 755 was published, each frequency regulation market rules of the North American ISO/RTO have been revised in many parts. In 2016, the domestic CBP market has also changed its market rules to allow ESS to participate in the frequency regulation reserve services(Governor Free and Automatic Generation Control). This paper compares and analyzes the changed North American ISP/RTO market and domestic CBP market rules. In particular, we compare PJM and CAISO frequency regulation market pricing mechanism and settlement rules with the settlement rules of the domestic CBP market and compare the factors of each market used to compensate the participating resources in terms of resource dependency and accuracy.

135MVA 수력 발전기의 전력 시스템 안정화 장치 적용 효과 분석 (An Analysis of Power System Stability(PSS) Effect with 135MVA Hydro Generator)

  • 옥연호;이은웅;변일환;오석영
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1100-1104
    • /
    • 2009
  • As national power consumption every year increases, the power plant which is in the process of planning tries to establish high-capacity generator. The power system tends to become a large size. With the progress of electronic components, the control systems of the generator have been digitalized and rapid-response control system is possible. However, the minute frequency vibration of grid occurred with the effect of rapid-response control system. To solve these problem, PPS(Power System Stability) has been introduced since 2004, and it has being installed and applied to the thermal and nuclear power plant which are high-capacity, over 800MVA. However the minute frequency vibration is gradually changed to the bigger frequency vibration by fast-action control system, and this regional frequency fluctuation might be diffused wide area. Therefore, it is applied to the hydro generator which is small with fast-action governor system, and it is necessary to control the minute frequency vibration to prevent to diffuse. In this paper, the effect will be proved by establishing PSS on the Hydro-Generator which has both digital excitation and governor system for the first time in Korea.