• Title/Summary/Keyword: Electron-Beam

Search Result 2,213, Processing Time 0.042 seconds

Study of Coherent High-Power Electromagnetic Wave Generation Based on Cherenkov Radiation Using Plasma Wakefield Accelerator with Relativistic Electron Beam in Vacuum (진공 내 상대론적인 영역의 전자빔을 이용한 플라즈마 항적장 가속기 기반 체렌코프 방사를 통한 결맞는 고출력 전자파 발생 기술 연구)

  • Min, Sun-Hong;Kwon, Ohjoon;Sattorov, Matlabjon;Baek, In-Keun;Kim, Seontae;Hong, Dongpyo;Jang, Jungmin;Bhattacharya, Ranajoy;Cho, Ilsung;Kim, Byungsu;Park, Chawon;Jung, Wongyun;Park, Seunghyuk;Park, Gun-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.407-410
    • /
    • 2018
  • As the operating frequency of an electromagnetic wave increases, the maximum output and wavelength of the wave decreases, so that the size of the circuit cannot be reduced. As a result, the fabrication of a circuit with high power (of the order of or greater than kW range) and terahertz wave frequency band is limited, due to the problem of circuit size, to the order of ${\mu}m$ to mm. In order to overcome these limitations, we propose a source design technique for 0.1 THz~0.3 GW level with cylindrical shape (diameter ~2.4 cm). Modeling and computational simulations were performed to optimize the design of the high-power electromagnetic sources based on Cherenkov radiation generation technology using the principle of plasma wakefield acceleration with ponderomotive force and artificial dielectrics. An effective design guideline has been proposed to facilitate the fabrication of high-power terahertz wave vacuum devices of large diameter that are less restricted in circuit size through objective verification.

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Effects of Postoperative Radiation Therapy for Prevention of Keloids and Hypertrophic Scars (켈로이드와 비후성 반혼에서 재발을 방지하기 위한 수술후 방사선치료의 효과)

  • Kang, Ki-Mun;Choi, Ihl-Bohng;Kim, In-Ah;Jang, Jee-Young;Shinn, Kyung-Sub
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.269-276
    • /
    • 1997
  • Purpose : To evaluate the effects of surgical excision followed by radiation therapy for Prevention of keloids and hypertrophic scars. Materials and Methods : From October 1987 to April 1995, radiation therapy was applied to 167 sites in 106 patients with surgical excision in an attempt to prevention of recurrence against keloids and hypertrophic scars. The main etiology of the keloids and hypertrophic scars were surgery in $49.2\%,\;trauma\;in\;25.0\%,\;ear-piercing\;in\;5.4\%,\;and\;burn\;in\;5.4\%$, The Patients' ages ranged from 3 to 70 years with a median of 32 years. Radiation therapy used ranged from 6 to 8MeV electron beam. Radiation therapy was delivered within 24 hours of surgical excision. Several dose schedules were used, varing from 400cGy in 1 daily fraction to 1900cGy in 4 daily fractions. The average total dose was 1059cGy, and the average dose per fraction was 433cGy. All patients were followed up from 24 to 114 months with a median follow up of 49 months. Results : The overall recurrence rate was $12.6\%$ (21/167) The overall 1-year and 2-year recurrence rates were $10.2\%\;and\;11.4\%$, respectively Among 21 recurrent sites, seventeen sites $(81\%)$ were confirmed within 12 months after surgical excision. Period to recurrence ranged from 1 month to 47 months with a median recurrence time of 9.6 months, The history of previous therapy was only a significant factor in recurrence. Twenty-four patients had history of previous therapy recurrence rates was significantly higher in this group than those without history of Previous therapy $(22.6\%\;vs.\;11.0\%,\;p=0.04)$. There was no serious complication related to radiation therapy. Conclusion : This study suggests that surgical excision followed by radiation therapy is an effective method of preventing keloids and hypertrophic scars.

  • PDF

핵융합로용 플라즈마 대향부품 개발을 위해 제작된 텅스텐/FM강 HIP 접합 목업의 수명 평가 해석

  • Lee, Dong-Won;Sin, Gyu-In;Kim, Seok-Gwon;Jin, Hyeong-Gon;Lee, Eo-Hwak;Yun, Jae-Seong;Mun, Se-Yeon;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.452-452
    • /
    • 2014
  • 블랑켓 일차벽이나 디버터와 같은 핵융합로 플라즈마 대향부품은 플라즈마로부터 입사되는 중성자 및 입자들을 차폐하여 구조물을 보호하고, 발생열을 에너지로 변환하기 위해 냉각재를 활용한 열제거 기능을 담당한다. 특히, 고속중성자와 입사 열부하 및 여러 입자들로부터 블랑켓 및 내부 구조물을 보호하기 위해 차폐체와 구조물로 구성된다. 세계적으로 차폐체로서는 텅스텐 혹은 텅스텐 합금, 구조물용 재료로는 저방사화 Ferritic Martensitic (FM) 강이 유력한 후보재료로 개발, 연구 중에 있다. 국내에서는 국제핵융합로(ITER) 사업을 통해 고온등방가압(HIP, Hot Isostatic Pressing)을 이용한 이종금속간 접합기술과 한국형 저방사화 고온구조재료인 ARAA (Advanced Reduced Activation Alloy)가 개발되고 있으며, 이를 활용한 설계, 접합법 개발, 제작목업의 건전성 평가 등이 수행되고 있다. 한국원자력연구원에서는 핵융합 기초사업의 일환으로 전북대와 공동으로 수행 중인 건전성 평가체계 개발을 위해, 기 개발된 접합법을 활용한 $45mm(H){\times}45mm(W){\times}2mm(T)$의 W/FM강 목업을 제작한 바 있으며, 이를 국내 구축된 고열부하 시험 장비인 KoHLT-EB (Electron Beam)를 활용한 고열부하 인가 건전성 평가시험을 준비 중에 있다. 이종금속간 접합 특성은 기계적 평가를 위한 파괴시험을 통해 검증, 이를 활용한 목업이 제작되었으며, 제작된 목업에 대한 초음파를 이용한 접합면의 비파괴 검사를 통해 결함이 없음을 확인하였다. 최종적으로 실제 사용되는 핵융합 운전조건과 유사 혹은 가혹한 조건에서 고열부하를 인가하여, 그 건전성을 평가가 이루어질 것이다. 고열부하 시험을 위해서는 냉각조건, 인가 열부하, 수명평가를 통한 반복 고열부하 인가 횟수 등이 사전에 결정되어야 한다. 이를 위해 상업용 열수력, 구조해석 코드인 ANSYS-CFX와 -mechanical을 이용한 시험조건 모의 및 수명 평가가 수행되었다. 구축 장비의 냉각계통을 고려하여 냉각수의 온도 및 속도는 $25^{\circ}C$, 0.15 kg/sec로, 열부하는 0.5 및 $1.0MW/m^2$에 대해 모의를 수행하였다. 정상상태 시 텅스텐의 최대 온도는 각 열부하 조건에 따라 $285.3^{\circ}C$$546.8^{\circ}C$였으며, 이에 도달하는 시간을 구하기 위해 천이해석을 수행하였고, 이를 통해 30초에 최대온도 95 %이상의 정상상태 온도에 도달함을 확인하였다. 또한, 목업의 초기 온도에 도달하는 냉각시간도 동일한 천이해석을 통해 30초로 가능함을 확인하였고, 최종 시험 조건을 30초 가열, 30초 냉각으로 결정하였다. 결정된 반복 열부하 인가 조건에서 이종금속 접합체가 받는 다른 열팽창 정도에 따른 응력을 계산하여 목업의 수명을 도출하였고, 이를 시험해야 할 반복 횟수로 결정하였다. 각 열부하 조건에 따른 온도조건을 ANSYS-mechanical 코드를 활용하여 열팽창과 이에 따른 접합면의 응력분포로 계산하였다. 0.5 및 $1.0MW/m^2$에 대해, 목업이 받는 최대 응력은 334.3 MPa와 588.0 MPa 였으며, 이 때 텅스텐과 FM강이 받는 strain을 도출하여 물성치로 알려진 cycle to failure 값을 도출하였다. 열부하에서 예상되는 수명은 0.5 및 $1.0MW/m^2$에 대해, 100,000 사이클 이상과 2,655 사이클로 계산되었으며, 시간적 제약을 고려 최종 평가는 $1.0MW/m^2$에 대해, 3,000사이클 정도의 실험을 통해 그 수명까지 접합건전성이 유지되는 지 실험을 통해 평가할 예정이다.

  • PDF

Trend in Research and Application of Hard Carbon-based Thin Films (탄소계 경질 박막의 연구 및 산업 적용 동향)

  • Lee, Gyeong-Hwang;Park, Jong-Won;Yang, Ji-Hun;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.111-112
    • /
    • 2009
  • Diamond-like carbon (DLC) is a convenient term to indicate the compositions of the various forms of amorphous carbon (a-C), tetrahedral amorphous carbon (ta-C), hydrogenated amorphous carbon and tetrahedral amorphous carbon (a-C:H and ta-C:H). The a-C film with disordered graphitic ordering, such as soot, chars, glassy carbon, and evaporated a-C, is shown in the lower left hand corner. If the fraction of sp3 bonding reaches a high degree, such an a-C is denoted as tetrahedral amorphous carbon (ta-C), in order to distinguish it from sp2 a-C [2]. Two hydrocarbon polymers, that is, polyethylene (CH2)n and polyacetylene (CH)n, define the limits of the triangle in the right hand corner beyond which interconnecting C-C networks do not form, and only strait-chain molecules are formed. The DLC films, i.e. a-C, ta-C, a-C:H and ta-C:H, have some extreme properties similar to diamond, such as hardness, elastic modulus and chemical inertness. These films are great advantages for many applications. One of the most important applications of the carbon-based films is the coating for magnetic hard disk recording. The second successful application is wear protective and antireflective films for IR windows. The third application is wear protection of bearings and sliding friction parts. The fourth is precision gages for the automotive industry. Recently, exciting ongoing study [1] tries to deposit a carbon-based protective film on engine parts (e.g. engine cylinders and pistons) taking into account not only low friction and wear, but also self lubricating properties. Reduction of the oil consumption is expected. Currently, for an additional application field, the carbon-based films are extensively studied as excellent candidates for biocompatible films on biomedical implants. The carbon-based films consist of carbon, hydrogen and nitrogen, which are biologically harmless as well as the main elements of human body. Some in vitro and limited in vivo studies on the biological effects of carbon-based films have been studied [$2{\sim}5$].The carbon-based films have great potentials in many fields. However, a few technological issues for carbon-based film are still needed to be studied to improve the applicability. Aisenberg and Chabot [3] firstly prepared an amorphous carbon film on substrates remained at room temperature using a beam of carbon ions produced using argon plasma. Spencer et al. [4] had subsequently developed this field. Many deposition techniques for DLC films have been developed to increase the fraction of sp3 bonding in the films. The a-C films have been prepared by a variety of deposition methods such as ion plating, DC or RF sputtering, RF or DC plasma enhanced chemical vapor deposition (PECVD), electron cyclotron resonance chemical vapor deposition (ECR-CVD), ion implantation, ablation, pulsed laser deposition and cathodic arc deposition, from a variety of carbon target or gaseous sources materials [5]. Sputtering is the most common deposition method for a-C film. Deposited films by these plasma methods, such as plasma enhanced chemical vapor deposition (PECVD) [6], are ranged into the interior of the triangle. Application fields of DLC films investigated from papers. Many papers purposed to apply for tribology due to the carbon-based films of low friction and wear resistance. Figure 1 shows the percentage of DLC research interest for application field. The biggest portion is tribology field. It is occupied 57%. Second, biomedical field hold 14%. Nowadays, biomedical field is took notice in many countries and significantly increased the research papers. DLC films actually applied to many industries in 2005 as shown figure 2. The most applied fields are mold and machinery industries. It took over 50%. The automobile industry is more and more increase application parts. In the near future, automobile industry is expected a big market for DLC coating. Figure 1 Research interests of carbon-based filmsFigure 2 Demand ratio of DLC coating for industry in 2005. In this presentation, I will introduce a trend of carbon-based coating research and applications.

  • PDF

New Approaches for Overcoming Current Issues of Plasma Sputtering Process During Organic-electronics Device Fabrication: Plasma Damage Free and Room Temperature Process for High Quality Metal Oxide Thin Film

  • Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.100-101
    • /
    • 2012
  • The plasma damage free and room temperature processedthin film deposition technology is essential for realization of various next generation organic microelectronic devices such as flexible AMOLED display, flexible OLED lighting, and organic photovoltaic cells because characteristics of fragile organic materials in the plasma process and low glass transition temperatures (Tg) of polymer substrate. In case of directly deposition of metal oxide thin films (including transparent conductive oxide (TCO) and amorphous oxide semiconductor (AOS)) on the organic layers, plasma damages against to the organic materials is fatal. This damage is believed to be originated mainly from high energy energetic particles during the sputtering process such as negative oxygen ions, reflected neutrals by reflection of plasma background gas at the target surface, sputtered atoms, bulk plasma ions, and secondary electrons. To solve this problem, we developed the NBAS (Neutral Beam Assisted Sputtering) process as a plasma damage free and room temperature processed sputtering technology. As a result, electro-optical properties of NBAS processed ITO thin film showed resistivity of $4.0{\times}10^{-4}{\Omega}{\cdot}m$ and high transmittance (>90% at 550 nm) with nano- crystalline structure at room temperature process. Furthermore, in the experiment result of directly deposition of TCO top anode on the inverted structure OLED cell, it is verified that NBAS TCO deposition process does not damages to the underlying organic layers. In case of deposition of transparent conductive oxide (TCO) thin film on the plastic polymer substrate, the room temperature processed sputtering coating of high quality TCO thin film is required. During the sputtering process with higher density plasma, the energetic particles contribute self supplying of activation & crystallization energy without any additional heating and post-annealing and forminga high quality TCO thin film. However, negative oxygen ions which generated from sputteringtarget surface by electron attachment are accelerated to high energy by induced cathode self-bias. Thus the high energy negative oxygen ions can lead to critical physical bombardment damages to forming oxide thin film and this effect does not recover in room temperature process without post thermal annealing. To salve the inherent limitation of plasma sputtering, we have been developed the Magnetic Field Shielded Sputtering (MFSS) process as the high quality oxide thin film deposition process at room temperature. The MFSS process is effectively eliminate or suppress the negative oxygen ions bombardment damage by the plasma limiter which composed permanent magnet array. As a result, electro-optical properties of MFSS processed ITO thin film (resistivity $3.9{\times}10^{-4}{\Omega}{\cdot}cm$, transmittance 95% at 550 nm) have approachedthose of a high temperature DC magnetron sputtering (DMS) ITO thin film were. Also, AOS (a-IGZO) TFTs fabricated by MFSS process without higher temperature post annealing showed very comparable electrical performance with those by DMS process with $400^{\circ}C$ post annealing. They are important to note that the bombardment of a negative oxygen ion which is accelerated by dc self-bias during rf sputtering could degrade the electrical performance of ITO electrodes and a-IGZO TFTs. Finally, we found that reduction of damage from the high energy negative oxygen ions bombardment drives improvement of crystalline structure in the ITO thin film and suppression of the sub-gab states in a-IGZO semiconductor thin film. For realization of organic flexible electronic devices based on plastic substrates, gas barrier coatings are required to prevent the permeation of water and oxygen because organic materials are highly susceptible to water and oxygen. In particular, high efficiency flexible AMOLEDs needs an extremely low water vapor transition rate (WVTR) of $1{\times}10^{-6}gm^{-2}day^{-1}$. The key factor in high quality inorganic gas barrier formation for achieving the very low WVTR required (under ${\sim}10^{-6}gm^{-2}day^{-1}$) is the suppression of nano-sized defect sites and gas diffusion pathways among the grain boundaries. For formation of high quality single inorganic gas barrier layer, we developed high density nano-structured Al2O3 single gas barrier layer usinga NBAS process. The NBAS process can continuously change crystalline structures from an amorphous phase to a nano- crystalline phase with various grain sizes in a single inorganic thin film. As a result, the water vapor transmission rates (WVTR) of the NBAS processed $Al_2O_3$ gas barrier film have improved order of magnitude compared with that of conventional $Al_2O_3$ layers made by the RF magnetron sputteringprocess under the same sputtering conditions; the WVTR of the NBAS processed $Al_2O_3$ gas barrier film was about $5{\times}10^{-6}g/m^2/day$ by just single layer.

  • PDF

Effect of Irradiation and Packaging Methods on the Oxidation of Cholesterol in Raw and Cooked Chicken Leg Meat (방사선 조사 및 포장방법이 생계육 및 조리계육의 콜레스테롤 산화에 미치는 영향)

  • Lee, J.I.;Shin, T.S.;Jin, S.K.;Kim, I.S.;Kim, Y.H.;Joo, S.T.;Park, G.B.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.825-834
    • /
    • 2003
  • Chicken thigh from a retail market were used as experimental samples. Some chicken samples of raw state were packaged with PVDC at an aerobic and vacuum condition. The other samples were cooked until core temperature arrived at 70$^{\circ}C$ and then packaged immediately in the same way of raw samples. After samples were irradiated by electron beam at 6 kGy, they were stored in a refrigerator. Identification and quantity of cholesterol oxides were made at 0 and 7 days of storage, respectively. During the early stage of storage, 7$\beta$-hydroxycholesterol, $\alpha$,$\beta$-epoxide, cholestanetriol and 7-ketocholesterol were produced from the raw meat samples, and the production of these chemicals were significantly higher(P〈0.05) from the samples with aerobic packaging than those with vacuum packaging. With storage time, 7$\alpha$-hydroxycholesterol, 6-ketocholesterol and some other chemicals, which were not found during the early stage of storage, were found. Also, the formation of these chemicals were significantly increased(P〈0.05) with storage time. Cholesterol and lipid oxidation products of cooked meat after irradiation and irradiated meat after cooking were significantly increased(P〈0.05) with storage time for all treatments, and vacuum packaging results in showed significantly lower value(P〈0.05) than aerobic packaging. Summarizing the aforementioned results, it was found that the formation of cholesterol and lipid oxides and lipid oxidation was more easily affected by packaging condition than irradiation.

Conservative Surgery and Primary Radiotherapy for Early Bresst Cancer: Yonsei Cancer Center Experience (조기 유방암에서 보존적 수술후 방사선치료: 연세암센터 경험)

  • Suh Chang Ok;Lee Hy De;Lee Kyung Sik;Jung Woo Hee;Oh Ki Keun;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.337-347
    • /
    • 1994
  • Breast conserving surgery and irradiation is now accepted as preferable treatment method for the patients with stage I and II breast cancer. Our institution activated team approach for breast conservation in 1991 and treated one hundred and fourty patients during the next three years. Purpose : To present our early experience with eligibility criteria, treatment techniques, and the morbidities of primary radiotherapy. Materials and Methods: Sixty four patients with early stage breast cancer who received breast conserving treatment between January 1991 and December 1992 were evaluated. All patients received partial mastectomy(wide excision to quadrantectomy) and axillary node dissection followed by radiotherapy. Total dose of 4500-5040 cGy in 5-5 1/2 weeks was given to entire involved breast and boost dose of 1000-2000 cGy in 1-2 weeks was given to the primary tumor site. Linac 4 MV X-ray was used for breast irradiation and electron beam was used for boost. Thirty five Patients received chemotherapy before or after radiotherapy. Patients characteristics, treatment techniques, and treatment related morbidities were analyzed. Results : Age distribution was ranged from 23 to 59 year old with median age of 40. Twenty-seven patients had T1 lesions and 34 patients had T2 lesions. In three patients, pathologic diagnosis was ductal carcinoma in situ. Thirty-seven Patients were N0 and 27 patients were Nl. There were three recurrences, one in the breast and two distant metastases during follow-up period(6-30 months, median 14 months). Only one breast recurrence occured at undetected separate lesion with microcalcifications on initial mammogram. There was no serious side reaction which interrupted treatment courses or severe late complication. Only one symptomatic radiation pneumonitis and one asymptomatic radiation pneumonitis were noted. Conclusions: Conservative surgery and primary radiotherapy for early breast cancer is Proven to be safe and comfortable treatment method without any major complication. Long-term follow up is needed to evaluate our treatment results in terms of loco-regional control rate, survival rate, and cosmetic effect.

  • PDF

Effect of Irradiation, Packaging and Storage on the Oxidation of Cholesterol and Lipid in Pork Longissimus Meat (돈육 등심의 콜레스테롤 및 지질 산화에 전자선 조사, 포장 및 저장기간이 미치는 영향)

  • 신택순;이정일
    • Food Science of Animal Resources
    • /
    • v.22 no.2
    • /
    • pp.137-144
    • /
    • 2002
  • Pork loins that retailed in market were used as experimental samples. Some pork samples in raw state were packaged with PVDC in either aerobic or vacuum condition. The other pork samples were cooked until core temperature reached at 70$\^{C}$ and then packaged immediately in the same way with the raw samples. After these samples were irradiated by electron beam 6 kGy, the samples were stored in a refrigerator (2∼4$\^{C}$). Identification and quantification of cholesterol oxides were performed at 0 and 7 days. The results were following. During the early stage of storage, cholesterol oxides were not produced from the raw meat samples, but with the passage of storage time,7 $\alpha$-hydroxycholesterol, 7$\beta$-hydroxycholesterol, 7-ketocholesterol, 20 $\alpha$-hydroxycholesterol, $\beta$-epoxide and $\alpha$-epoxide, which were not produced during the early stage of storage, were produced. The production of cholesterol and lipid oxidation products were significantly higher (P<0.05) in the meats with aerobic packaging than those with vacuum packaging, Cooked meat after irradiation showed 7 $\alpha$-hydroxycholesterol, 7 $\beta$-hydroxycholesterol, $\alpha$-epoxide and cholestanetriol on the 7th day of storage, although those chemicals were not produced during the early stage of storage. Production of cholesterol oxides was significantly increased (P<0.05) with the passage of storage time for all treatments, and showed significantly lower value (P<0.05) with the vacuum packaging than these for aerobic packaging. Species of cholesterol oxides from irradiated meat after cooking were similar to those from cooked meat after irradiation. Collectively, it was found that the production of cholesterol oxides was more easily affected by packaging condition than irradiation.