266 nm 파장을 갖는 Nd : YAG 레이저를 이용한 펄스레이저증착법(PLD)에 의해 모재인 $Al_2O_3$ 입자표면에 코팅된 $TiO_2$ 나노 입자를 제조하였다. 펄스레이저 에너지는 100 mJ/pulse로 고정하였으며, 레이저가 $TiO_2$ 타겟에 조사되는 동안 아르곤 가스를 챔버 내로 공급하였다. 이때, 압력은 $1{\times}10^{-2}Pa$에서 100 Pa로 변화시겼다. 증착된 나노 입자의 형태와 특성에 대한 증착 압력의 효과는 투과전자현미경과 에너지 분산형 X선 분광기를 이용하여 조사하였다. 모재 표면($Al_2O_3$)에 흡착된 나노 입자는 거의 구형이며 10~30 nm의 크기를 갖는다. 증착된 나노 입자의 형태는 기체 압력에 큰 영향을 받지 않는다. 그러나, 증착된 나노입자의 크기와 결정성은 기체 분압이 증가함에 따라서 증가한다. 이 방법에 의해서, 증착된 나노입자의 크기와 결정성은 기체 압력에 의해서 쉽게 조정할 수 있다.
Ion irradiation is a very promising tool to modify the chemical structure and physical properities of polymers. This study was aimed to evaluate the cellular adhesion to ion beam-irradiated surface of biodegradable poly-l-lactide(PLLA) membrane. The PLLA membrane samples were irradiated by using 35 KeV $Ar^+$ to fluence of $5{\times}10^{13}$, $5{\times}10^{14}$ and $5{\times}10^{15}\;ion/cm^2$. Water contact angles to control and each dose of ion beam-irradiated PLLA membranes were measured. Cultured fetal rat calvarial osteoblasts were seeded onto control and each dose of ion beam-irradiated PLLA membranes and cultured. After 24 hours, each PLLA membranes onto which osteoblasts attached were examined by scanning electron microscopy(SEM). Osteoblasts were removed from each PLLA membrane and then, the vitality and the number of cells were calibrated. Alkaline phosphatase of detached cells from each PLLA membranes were measured. Ion beam-irradiated PLLA membranes showed no significantly morphological change from control PLLA membranes. In the measurement of water contact angle to each membrane, the dose range of ion beam employed in this study reduced significantly contact angles. Among them, $5{\times}10^{14}\;ion/cm^2$ showed the least contact angle. The vitalities of osteoblastes detached from each membranes were confirmed by flow cytometer and well attached cells with their own morphology onto each membranes were observed by SEM. A very strong improvement of the cell adhesion and proliferation was observed for ion beam-irradiated surfaces of PLLA membranes. $5{\times}10^{15}\;ion/cm^2$ exhibited the most strong effect also in cellular adherence. ALPase activities also tended to increase in ion beam-irradiated membranes but statistical differences were not found. These results suggested that ion beam irradiation is an effective tool to improve the adhesion and spreading behaviour of the cells onto the biodegradable PLLA membranes for the promotion of membrane-tissue integration.
Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).
고분자전해질 연료전지 (PEMFC)의 공기극을 양극산화 알루미늄 (AAO) 템플레이트를 이용하여 제조하고 촉매층의 구조적 특성을 주사현미경 (SEM) 측정과 BET (Brunauer-Emmett-Teller) 분석을 통해 알아보았다. SEM 측정을 통해 일정한 크기와 모양의 Pt nanowire 가 규칙적으로 형성된 것을 확인할 수 있었다. BET 분석을 통해 AAO 템플레이트로 인하여 20-100 nm 크기의 기공 분포가 증가한 것을 확인하였다. 단위전지 성능평가와 임피던스 측정을 통하여 막-전극접합체 (MEA)의 전기화학적 특성을 분석하였다. 그 결과, AAO 템플레이트를 이용하여 제조한 MEA는 촉매층의 구조 개선으로 인하여 물질 전달 저항을 감소시킬 수 있었으며, 25%의 단위전지 성능이 향상되었다.
티타늄 나프테네이트를 출발 원료로 사용하고 스핀코팅-열분해법을 이용하여 소다-라임-실리카 슬라이드 유리기판 위에 $TiO_2$ 박막을 제조하였다. 도포된 박막은 $500^{\circ}C$로 10분간 공기분위기에서 전열처리를 행하였고, 최종 열처리는 500, 550과 $600^{\circ}C$로 30분간 공기분위기에서 각각 행하였다. X-선 회절분석법을 이용하여 박막의 결정화도를 조사하였고, 전계 방출 주사형 전자 현미경과 원자간력 현미경을 이용하여 $TiO_2$ 박막의 표면미세구조와 표면 거칠기를 조사하였다. 550 과 $600^{\circ}C$로 최종 열처리한 박막의 X-선 회절분석 결과, 아나타제 상만이 존재하였다. 500과 $550^{\circ}C$로 열처리한 박막의 표면은 균질하였으나, 열처리온도가 $600^{\circ}C$로 증가함에 따라서, 박막의 표면에는 바늘모양의 상이 3차원적으로 성장하였다. 모든 박막에 있어서 가시영역에서의 투과율은 500nm에서 90% 이상의 높은 값을 나타냈다. 박막의 광촉매특성을 조사하기 위하여 stearic acid가 코팅된 박막에 365nm 파장의 UV를 2.4mW/$\textrm{cm}^2$의 강도로 조사하여 C-H모드에 대한 IR 흡수단의 변화를 관찰하였다.
$^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.
비균일계 촉매의 일반적인 형태는 촉매로서 활성이 있는 금속 혹은 금속 화합물을 표면적이 넓은 다공성 물질인 지지체에 분산 담지시켜서 금속의 표면적을 높이고 이로부터 금속의 분산이 높아지면서 촉매로서의 활성도 높아져 일반적인 반응에 응용되고 있다. 그러나 본 연구에서는 금속염을 이용한 액상 촉매의 제조 및 응용에 초점을 맞추었다. 일반적인 금속염들은 높은 온도에서도 용융되지 않지만 이 금속염 화합물에 다른 금속염 화합물을 함께 섞어 혼합시키면 이 혼합물이 보통의 비균일 촉매 반응온도인 $200^{\circ}C$에서 $400^{\circ}C$의 범위에서 액상으로 존재할 수 있게 된다. 고온에서 액상형태가 되는 용융된 금속염 혼합물(molten salt)을 지지체의 세공 내에 담지시켜 담지된 액상 촉매로서의 가능성을 알아보고 이들의 촉매 제조와 표면 연구에 초점을 맞추었다. 이들 금속염 혼합물은 종류가 매우 다양하여 여러 종류의 금속에 대하여 혼합염을 선택하여 응용할 수 있다. 본 연구에서는 일반적인 촉매로 많이 이용되고 있는 구리를 선정하고 이의 염화물인 염화구리(CuCl)와 함께 혼합되어 용융될 수 있는 금속염 혼합물을 만들기 위해 칼륨 염화물을 선택하여 CuCl-KCl 혼합염을 촉매 제조에 이용하였다. 이 금속염 혼합물을 지지체에 첨가시킨 양은 담지 시킬 알루미나 세공 부피의 약 25%로 하여 용융된 금속염의 표면적이 넓어지도록 하였고 제조 후의 표면은 SEM와 EDS를 이용하여 분석하였다. 금속염 혼합물은 염산 수용액을 이용하여 함침법으로 담지 시켰으며 제조한 직후와 제조한 후 금속염 혼합물을 용융점 이상으로 3 h 동안 열처리 한 후의 표면을 비교하였다. 실험 결과 표면에서의 CuCl-KCl의 조성은 일정하지 않았지만 이 열처리가 표면에서 금속염 혼합물의 형성을 촉진시키고 있음을 알 수 있었다.
Tribenzylamine(TBA), tetrabenzylethylenediamine(TBEDA), pentabenzyldiethylenetriamine(PBDETA)을 중성운반체로 이용한 막전극은 각각 pH 1~pH 9, pH 2~pH 12, pH 4~pH 12 범위에서 수소이온에 선택적이고 선형적인 감응을 나타내었다. TBA, TBEDA, PBDETA로 만든 막전극은 비공유전자쌍 수의 증가와 수소이온 선택성 사이에는 무관 하였고 각각에 대한 기울기는 43.8mV/pH, 46.9mV/pH, 43.6mV/pH를 나타냈다. 각 전극에 대하여 알칼리금속이온($Li^+$, $Na^+$, $K^+$) 및 알칼리토금속이온($Ba^{2+}$, $Ca^{2+}$, $Mg^{2+}$), 전이금속이온($Mn^{2+}$, $Co^{2+}$, $Ni^{2+}$, $Cu^{2+}$, $Zn^{2+}$)에 대한 방해이온을 측정하였다. 선택계수는 분리용액법을 이용하여 측정하였고 TBEDA를 이용한 막이 가장 좋은 결과를 나타내었다.
Chloropicrin은 국내에서는 사용되지 않으며, 잔류허용기준이 불검출로 설정된 농약이다. 그러나 중국에서는 훈증제, 살균제, 살선충제 및 저장 곡물의 살충제로 사용되고 있으며, 잔류허용기준이 설정되어 있다. 따라서 본 연구에서는 중국 등에서 수입하는 식품 중 국내에서 사용하지 않는 농약에 대한 안전성을 확보하기 위하여 해당 농약을 신속하고 빠르게 검출할 수 있는 시험법을 개발하고자 하였다. Chloropicrin은 분자량이 작고 휘발성이 큰 화합물이므로 헤드스페이스 추출법을 활용하여 검체 추출액을 직접 GC에 주입하는 시험법을 개발하였으며, 확립된 시험법을 검증한 결과 회수율이 77.7~79.3%로 조사되어 코덱스 국제가이드라인(CAC/GL 40)에 적합함을 확인하였다. 정량한계 또한 0.05 mg/kg 이하로 매우 우수한 감도를 가지고 있음을 확인하였으며, GC-MS를 이용한 재확인과정을 추가로 확립하여 본 시험법의 신뢰도를 높였다. 확립된 시험법은 식품에 잔류할 수 있는 농약의 기준 준수여부에 대한 적합성을 판단하기 위한 공정시험법으로 활용되고 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.