• 제목/요약/키워드: Electron microscope

검색결과 4,377건 처리시간 0.032초

Bacteria를 이용한 연약한 흙의 고결화 가능성 (Possibility of cementation of soft soil using Bacteria)

  • 김대현;김호철;박경호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.379-391
    • /
    • 2010
  • In order to understand the mechanism of cementation of soft soils treated with bacteria, three types of specimens(untreated, normal bacteria concentration treated, and high bacteria concentration treated) were made. Scanning Electron Microscope(SEM), EDX and X-ray diffraction(XRD) analyses were performed on the soft silt and loose sand specimens. Compared with the untreated specimen, a clearer cementation between particles was observed in the high bacteria concentration treated specimen. Based on the scanning electron microscope(SEM) EDX analyses, more calcium carbonate was observed in the specimen treated with high bacteria concentration than other specimens. On the basis of the preliminary results, it appears that microbial cementation can occur in the soft soil. Further study on the cementation of soils using bacteria is necessary to validate this result.

  • PDF

HU-125C 전자현미경에 있어서 카메라 상수의 변화 및 상의 회전에 대한 조사 (Variation of Camera Constant and Image Rotation in HU-125C Electron Microscope)

  • 최주;예길촌
    • Applied Microscopy
    • /
    • 제4권1호
    • /
    • pp.1-4
    • /
    • 1974
  • Hitachi HU-125C 전자현미경에 있어서 각 렌즈 전류의 연동에 따른 카메라 상수의 변화를 주사하였다. 시료의 높이 변화가 카메라 상수의 변동에 현저한 영향을 끼치고 있음도 알 수 있었다. 전자회절상과 시편상의 회전은 결정시료를 사용하여 측정하였다. 금속박막을 조사연구함에 있어서 전자현미경의 실제석인 조작방안을 적정화하기 위한 몇 가지 문제를 조사하였다. 본 실험진행을 전자현미경 작업을 통하여 크게 도와 준 김수철씨에게 진심으로 감사드립니다.

  • PDF

자동차용 스틸휠 디스크부품의 성형불량 및 파손사례분석 (Analysis of Damaged Instance and Forming Fault for Disc Part in Automotive Steel Wheel)

  • 이성희;김무연;김태규;윤호영;강석우
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.234-238
    • /
    • 2006
  • In this research, an analysis of damaged instance and forming fault for disc part in automotive steel wheel was performed. Rolled steel material, which had been used in the manufacturing of the damaged disc part, was prepared for tensile test, quantitative analysis of chemical component and acquirement of scanning electron microscope images. Although the results of mechanical properties and chemical component ratio for the material satisfied the suggested specification, some material inherent problem was found in the scanning electron microscope images. Finally, in an analysis of chemical component for the damaged disc part used in road condition, mismatching of chemical component ratio between the suggested specification and test result was found.

  • PDF

신경망과 주사전자현미경을 이용한 플라즈마 진단 (Plasma Diagnosis by Using Scanning Electron Microscope and Neural Network)

  • 배중기;김병환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.96-98
    • /
    • 2006
  • A new ex-situ model to diagnose a plasma processing equipment was presented. The model was constructed by combining wavelet, scanning electron microscope, ex-situ measurement of etching profile, and neural network. The diagnosis technique was applied to a tungsten etching process, conducted in a $SF_6$ helicon plasma. The wavelet was used to characterize detailed variations of plasma-etched surface. The diagnosis model was constructed with the vertical wavelet component. For comparison, a conventional model was built by using the estimated profile data. Compared to the conventional model, the wavelet-based model, demonstrated a much improved diagnosis.

  • PDF

의치상 레진의 중합 방법에 따른 크기의 안정성 및 표면 형태에 관한 연구 (DIMENSIONAL STABILITY AND SURFACE MORPHOLOGY OF VARIOUS DENTURE RESINS)

  • 채숙영;방몽숙
    • 대한치과보철학회지
    • /
    • 제30권3호
    • /
    • pp.401-410
    • /
    • 1992
  • The purpose of this study was to investigate the dimensional changes and surface morphology of dentures processed by various polymerization conditions. The measurements were done by taking radiograph and using vernier calipers and each specimen was observed on scanning electron microscope. Results obtained were as follows. 1. The difference of dimensional stability was not recognized between various polymerization conditions(heat-cured resin, pour-type resin, microwave-cured resin, and injection molding resin). 2. There were expansion and shrinkage in the occlusal dimension, shrinkage in the frontal dimension, and expansion in the lateral dimension. 3. Scanning electron microscope pictures of heat-cured resin showed dense and regular surface morphology. 4. Microwave-cured resin surface appeared more regular and smooth than pour-type resin but less dense and more irregular than heat-cured resin. 5. Scanning electron microscope pictures of pour-type resin with the lowest dimensional change showed the most irregular surface morphology.

  • PDF

Sc 첨가에 따른 Al-6Si-2Cu 합금의 미세조직 개량화 (Effect of Sc Addition on the Microstructure Modification of Al-6Si-2Cu Alloy)

  • 안성빈;김정석
    • 열처리공학회지
    • /
    • 제35권3호
    • /
    • pp.150-158
    • /
    • 2022
  • The effects of scandium addition on the Al-6Si-2Cu Alloy were investigated. The Al-6Si-2Cu-Sc alloy was prepared by gravity die casting process. In this study, scandium was added at 0.2 wt%, 0.4 wt%, 0.8 wt%, and 1.0 wt%. The microstructure of Al-6Si-2Cu-Sc alloy was investigated using Optical Microscope, Field Emission Scanning Electron Microscope, Electron Back Scatter Diffraction, and Transmission Electron microscope. The microstructure of Al-6Si-2Cu alloy with scandium added changed from dendrite structure to equiaxed crystal structure in specimens of 0.4 wt% Sc or more, and coarse needle-shape eutectic Si and β-Al5FeSi phases were segmented and refined. The nanosized Al3Sc intermetallic compound was observed to be uniformly distributed in the modified Al matrix.

Stem cell behaviors on periodic arrays of nanopillars analyzed by high-resolution scanning electron microscope images

  • Jihun Kang;Eun-Hye Kang;Young-Shik Yun;Seungmuk Ji;In-Sik Yun;Jong-Souk Yeo
    • Applied Microscopy
    • /
    • 제50권
    • /
    • pp.26.1-26.3
    • /
    • 2020
  • The biocompatible polyurethane acrylate (PUA) nanopillars were fabricated by soft lithography using three different sizes of nanobeads (350, 500, and 1000 nm), and the human adipose-derived stem cells (hASCs) were cultured on the nanopillars. The hASCs and their various behaviors, such as cytoplasmic projections, migration, and morphology, were observed by high resolution images using a scanning electron microscope (SEM). With the accurate analysis by SEM for the controlled sizes of nanopillars, the deflections are observed at pillars fabricated with 350- and 500- nm nanobeads. These high-resolution images could offer crucial information to elucidate the complicated correlations between nanopillars and the cells, such as morphology and cytoplasmic projections.

수종의 치근형 골내매식체와 조직간의 반응에 관한 조직학적 연구 (HISTOLOGIC STUDY OF VARIOUS DENTAL IMPLANT-TISSUE INTERFACE)

  • 이호영;김영수
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.7-23
    • /
    • 1990
  • The success or failure of endosseous dental implants is related to the cellular activity at the implant surface. Success seems to be associated with the enclosure of the implant in a non-inflammed connective tissue or the formation of a direct bone implant interface. The purpose of this study was to examine the tissue reactions to the various implants at the submergible state in dog mandible. The $Br\"{a}nemark$, Core-Vent, Intergral, Bone spiral were selected for evaluation and also the Kimplant, Nephrite were used for the experimental study. After 4 months the animals were sacrificed. The interface zone between bone and implant was investigated using x-rays, light microscope, scanning electron microscope, transmission electron microscope. The following results were obtained from this study. 1. $Br\"{a}nemark$, Core-Vent, Kimplant, Integral showed no mobility and bone growth over the healing screws of the implants. Histologically most of the implant surface were covered by remodelled lamellar bone, and partly by a cellular layer or the thin fibrous tissue layer. 2. The Bone spiral showed no mobility and partially radiolucent line around the implant. The upper part of the implant was surrounded by a thin fibrous connective tissue and the middle, apical part of it were contacted with bone directly. 3. The Nephrite implant showed severe mobility and a radiolucent line around the implant. Histologically it showed mild inflammation and was surrounded by a fibrous connective tissue. 4. Scanning electron microscope showed that there was no amorphous ground substance in the Nephrite implant but the formation of ground substance over the collagen filaments in other implants. 5. Transmission electron microscope showed that collagen filaments were approached irregularly to the surface of all implants and in the $Br\"{a}nemark$, Core-Vent, Kimplant, Integral there was amorphous layer between the implant and the collagen filaments. It seemed to be ground substances.

  • PDF

전자빔 가공기의 지능형 원격 빔 조절 기능의 개발 (Development of Intelligent Remote Beam Control Function in E-Beam Manufacturing System)

  • 임선종;유준
    • 한국공작기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.24-29
    • /
    • 2006
  • The use electron-beam(E-beam) manufacturing system provides a means to alleviate optic exposure equipment's problems. We are developing an E-beam manufacturing system with scanning electron microscope(SEM) function. The E-beam manufacturing system consist of high voltage generator, beam blanker, condenser lenses, object lenses, stigmator and stage. The development of E-beam manufacturing system is used on the method of remaking SEM's structure. The functions of SEM are developed. It is important for the test of E-beam performance. In E-beam manufacturing system and SEM, beam focus is important function. In this paper, we propose intelligent remote control function for beam focus in E-beam manufacturing system. The function extends the user's function and gives convenience.