• Title/Summary/Keyword: Electron accelerator

Search Result 253, Processing Time 0.033 seconds

Simulation of Energy Resolution of Time of Flight System for Measuring Positron-annihilation induced Auger Electrons (양전자 소멸 Auger 전자 에너지 측정을 위한 Time of Flight의 분해도 향상에 관한 이론적 연구)

  • Kim, J.H.;Yang, T.K.;Lee, C.Y.;Lee, B.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.311-316
    • /
    • 2008
  • Since the presence of the chemical impurities and defect at surfaces and interfaces greatly influence the properties of various semiconductor devices, an unambiguous chemical characterization of the metal and semiconductor surfaces become more important in the view of the miniaturization of the devices toward nano scale. Among the various conventional surface characterization tools, Electron-induced Auger Electron Spectroscopy (EAES), X-ray Photoelectron Spectroscopy (XPS) and Secondary Electron Ion Mass Spectroscopy (SIMS) are being used for the identification of the surface chemical impurities. Recently, a novel surface characterizaion technique, Positron-annihilation induced Auger Electron Spectroscopy (PAES) is introduced to provide a unique method for the analysis of the elemental composition of the top-most atomic layer. In PAES, monoenergetic positron of a few eV are implanted to the surface under study and these positrons become thermalized near the surface. A fraction of the thermalized positron trapped at the surface state annihilate with the neighboring core-level electrons, creating core-hole excitations, which initiate the Auger process with the emission of Auger electrons almost simultaneously with the emission of annihilating gamma-rays. The energy of electrons is generally determined by employing ExB energy selector, which shows a poor resolution of $6{\sim}10eV$. In this paper, time-of-flight system is employed to measure the electrons energy with an enhanced energy resolution. The experimental result is compared with simulation results in the case of both linear (with retarding tube) and reflected TOF systems.

Radiotherapy Technique of High Energy Electron (고에너지 전자선의 방사선 치료 기술)

  • SUH M.W.;PARK J.I.;CHOI H.S.;KIM W.Y.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 1985
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefore, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed does, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under $3\%$ errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under $5\%$ errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatters; i.e., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Studies on Dose Distribution and Treatment Technique of High Energy Electron (고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究))

  • Lee, D.H.;Chu, S.S.
    • Journal of Radiation Protection and Research
    • /
    • v.3 no.1
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Performance Test of 4Cl Beamline for Protein Solution Scattering at the PLS (용액상의 단백질 구조 분석을 위한 PLS 4Cl빔라인의 성능 테스트)

  • Yu Chung-Jong;Kim Jehan;Kim Kwang-Woo;Kim Ghyung-Hwa;Lee Heung-Soo;Ree Moonhor;Kim Kyung-Jin
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.138-142
    • /
    • 2005
  • We tested performance of the 4C1 beamline for analyzing structures of proteins in solution using small angle X-ray scattering (SAXS) at the Pohang Light Source(PLS). Structurally well-known proteins such as lysozyme and $Bcl-XL(\vartriangle TM/\vartriangle loop)$ were used for the study. Low resolution solution structures of lysozyme and $Bcl-XL(\vartriangle TM/\vartriangle loop)$ were obtained at a resolution of at least i.2 nm, and the structures were basically same as those calculated from the crystal structures of the proteins. We also used $Bcl-XL(\vartriangle TM/\vartriangle loop)$ with a long flexible loop attached [$Bcl-XL(\vartriangleTM))$] and obtained significantly different data from $Bcl-XL(\vartriangle TM/\vartriangle loop)$, although the electron density map of the loop is known to be invisible from the crystal structure of $Bcl-XL(\vartriangleTM))$. We confirm that SAXS experiment is a powerful tool for the structural study of proteins in solution and the 4Cl beamline at the PLS is well-equipped and suitable for the protein solution SAXS experiment.

Theoreticel Analysis and Design of the Low-Energy Large-Aperture Electron Beam Generator (저에너지 대면적 전자빔 발생장치의 이론적 해석 및 설계에 관한 연구)

  • 우성훈;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.40-47
    • /
    • 1999
  • We have established a pulsed low-energy large-aIXTture electron beam(LELAEB) generation system with an energy of 2OO[keV], current of 1[A], pulse repetition rate of 200[Hz], and several tens of ${\mu}s$ pulse width. The system is characterized by a cold cathode that is simpler than the hot cathode. Electron beam does not need to be scanned over target objects because of large beam aIXTture of $300[\textrm{cm}^2]$. Electron source is secondary electrons that are generated when the ions from the glow discharge collide on the cathode surface. In this paper, We report about the design and manufacture of LELAEB generation system based on the theoretical analysis in order to study lXlssibility of increasing the efficiency of IELAEB accelerator. We also report on the possibility of large aperture beam current generation and the current density uniformity based on the experiIrental results.esults.

  • PDF

Status and Prospect of Free Electron Lasers (자유전자레이저의 개발현황과 전망)

  • Lee, Byung-Cheol;Jeong, Young-Ug;Park, Seong-Hee;Hahn, Sang-June
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.435-450
    • /
    • 2006
  • Free electron lasers (FELs) are promising sources of coherent radiation that can provide users with radiations having a wide-range frequency-tunability and good spectral characteristics for basic science and industrial applications. Especially in Terahertz or X-ray ranges of spectrum, FELs can generate much stronger radiations than conventional light sources. In this paper, we introduce the working principles and key technologies of FELs, the status and the prospects of FEL developments.

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

MO Theoretical Studies on Organic Accelerators of Vulcanization (유기 가황촉진제에 관한 분자 궤도론적 연구)

  • Ikchoon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.359-366
    • /
    • 1971
  • The extended Huckel calculations on five organic accelerators of vulcanization have been carried out. Various MO quantities e.g., electron populations and AO coefficients, are used to explain accelerator reactivity of the compounds. Results of these analyses lead us to support free radical mechanism of acceleration in vulcanization.

  • PDF

A Practical Method to Correct the Saturation Effect in XMCD Spectra

  • Kim, J.Y.
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.85-87
    • /
    • 2008
  • I report a simple method to correct the saturation effect in absorption spectra measured in total electron yield (TEY) mode. It does not require additional measurements of the X-ray penetration depth. In order to check the reliability of the method, X-ray magnetic circular dichroism (XMCD) spectra for polycrystalline Fe were measured at two different incident angles, and then processed with the method. The two resultant XMCD spectra were identical, and their sum rule analysis produced the ratios of orbital magnetic moment to spin magnetic moment, which were very close to the well-known value.

Mesurement of Collectively Accelerated Argon Ion Energy (집단 가속된 아르곤 이온의 에너지 측정)

  • 박인호;최은하
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.4
    • /
    • pp.425-430
    • /
    • 1995
  • 본 연구에서는 Marx Generator와 펄스 형성라인을 결합시켜 만든 VEBA(Versatile Electron Beam Accelerator)장치를 사용하여 아르곤 이온의 에너지를 식각 추적 방법을 써서 측정하였다. 이 장치에서 240kV, 30kA, 60ns의 전자빔이 발생되었다. 이 전자빔이 이극관을 통과하면서 이 때 주입된 아르곤 기체가 이온화되어 아르곤 이온이 얻어진다. 이렇게 형성된 이온은 가상적 음극에 의해 진공 전파관 속으로 가속되고 이를 전자빔과 분리한 후 알루미늄 박막으로 만든 식각 추적판을 때리도록 장치하였다. 이때 아르곤 이온이 뚫고 들어간 알루미늄 박막의 수로부터 이온의 에너지를 구하였다. 이렇게 얻어진 실험값은 이론값과 잘 일치하였다.

  • PDF