• Title/Summary/Keyword: Electron Probe

Search Result 731, Processing Time 0.03 seconds

Inhibition of Biological Perchlorate Reduction by Nitrate and Oxygen (질산염과 산소에 의한 생물학적 퍼클로레이트 환원의 저해)

  • Choi, Hyeok-Sun
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.29-34
    • /
    • 2009
  • In this study, a chloride ion probe as a direct measurement for perchlorate reduction was used to determine whether biological perchlorate reduction was inhibited by other electron acceptors ($O_2$ and ${NO_3}^-$) and to investigate competition of electron acceptors for using electron donors. Profiles of chloride production (= perchlorate reduction) in flasks containing perchlorate reducing populations were monitored by a chloride ion probe. Biological reduction of 2 mM perchlorate was inhibited by 2 mM nitrate that chloride production rate was decreased by 30% compared to perchlorate used as the only electron acceptor and chloride production rate was decreased by 70% when acetate was limited. Reduction of 2mM perchlorate was completely inhibited by oxygen at 7~8 mg/L, regardless of acetate excess / limitation.

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Immunocytochemistry, In situ hybridization and electron microscopy for early diagnosis of Aujeszky's in living pigs (오제스키병의 생체 조기진단을 위한 면역세포화학, In situ hybridization 및 전자현미경적 연구)

  • Moon, Oun-kyong;Kim, Soon-bok;Sur, Jung-hyang;Song, Geun-suk;Nho, Whan-gook
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.845-858
    • /
    • 1996
  • The purpose of this study was to establish early diagnostic methods for the detection of Aujeszky's disease viral antigens and nucleic acid in nasal cells, and buffy coats from experimentally infected living pigs by a combination of immunocytochemistry, in situ hybridization with digoxigenin(DIG)-labled probe and electron microscopy. Forty days old piglets were inoculated intranasally with $10^{7.0}TCID_{50}$ of Aujeszky's disease virus (ADV, NYJ-1-87 strain). The viral antigens and nucleic acid of ADV were detected in nasal cells, and buffy coat for 20 days after inoculation by immunocytochemistry, in situ hybridization with DIG-labeled probe and electron microscopical method. The results were compared with conventional methods such as a porcine Aujeszky's disease serodiagnostic(PAD) kit, neutralization test(NT) and virus isolation. 1. The viral antigens, nucleic acids and capsids of ADV were detected in nasal cells, buffy coats from 3 days to 20 days after inoculation by immunocytochemistry, in situ hybridization with DIG-labeled probe and electron microscopy, respectively. 2. When viral antigens were detected by the immunocytochemical technique, a diffuse brown deposit was observed in the nucleus and cytoplasm of nasal cells, buffy coats and PK-15 cells under a microscope. 3. DIG-labeled DNA probe was prepared by amplification of conserved sequence of recombinant ADV-gp50 clone with polymerase chain reacction. When ADV-DNA was detected by ISH with DIG-labeled probe, purplish blue pigmentation were observed in the nuclei and cytoplasms of ADV-infected cells under a microscope. Positive signals were observed in nasal cells and in the buffy coat and PK-15 cells at the first day after inoculation. 4. Where ADV-capsids were detected by transmission electron microscopical method, aggregation of capsids was observed in the nuclei and cytoplasms of nasal cells, buffy coats and PK-15 cells. The results suggested that these methods were considered as the highly sensitive and reliable tools for rapid and confirmative diagnosis of Aujeszky's disease in living pigs.

  • PDF

Gas Flow Rate Dependency of Etching Result: Use of VI Probe for Process Monitoring (가스 유량 변화에 따른 식각 공정 결과: VI Probe 활용 가능성 제안)

  • Song, Wan Soo;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.27-31
    • /
    • 2021
  • VI probe, which is one of various in-situ plasma monitoring sensor, is frequently used for in-situ process monitoring in mass production environment. In this paper, we correlated the plasma etch results with VI probe data with the small amount of gas flow rate changes to propose usefulness of the VI probe in real-time process monitoring. Several different sized contact holes were employed for the etch experiment, and the etched profiles were measured by scanning electron microscope (SEM). Although the shape of etched hole did not show satisfactory relationship with VI probe data, the chamber status changed along the incremental/decremental modification of the amount of gas flow was successfully observed in terms of impedance monitoring.

Applications of the Scanning Electron Microscope (주사형(走査型) 전자현미경(電子顯微鏡)의 응용분야(應用分野))

  • Kim, Yong-Nak
    • Applied Microscopy
    • /
    • v.2 no.1
    • /
    • pp.39-46
    • /
    • 1972
  • There are many kinds of microscopes suitable for general studies; optical microscopes(OM), conventional transmission electron microscopes (TEM), and scanning electron microscopes(SEM). The optical microscopes and the conventional transmission electron microscopes are very familiar. The images of these microscopes are directly formed on an image plane with one or more image forming lenses. On the other hand, the image of the scanning electron microscope is formed on a fluorescent screen of a cathode ray tube using a scanning system similar to television technique. In this paper, the features and some applications of the scanning electron microscope will be discussed briefly. The recently available scanning electron microscope, combining a resolution of about $200{\AA}$ with great depth of field, is favorable when compared to the replica technique. It avoids the problem of specimen damage and the introduction of artifacts. In addition, it permits the examination of many samples that can not be replicated, and provides a broader range of information. The scanning electron microscope has found application in diverse fields of study including biology, chemistry, materials science, semiconductor technology, and many others. In scanning electron microscopy, the secondary electron method. the backscattererd electron method, and the electromotive force method are most widely used, and the transmitted electron method will become more useful. Change-over of magnification can be easily done by controlling the scanning width of the electron probe. It is possible. to continuously vary the magnification over the range from 100 times to 1.00,000 times without readjustment of focusing. Conclusion: With the development of a scanning. electron microscope, it is now possible to observe almost all-information produced through interactions between substances and electrons in the form of image. When the probe is properly focused on the specimen, changing magnification of specimen orientation does not require any change in focus. This is quite different from the conventional transmission electron microscope. It is worthwhile to note that the typical probe currents of $10^{-10}$ to $10^{-12}\;{\AA}$ are for below the $10^{-5}$ to $10^{-7}\;{\AA}$ of a conventional. transmission microscope. This reduces specimen contamination and specimen damage due to heatings. Outstanding features of the scanning electron microscope include the 'stereoscopic observation of a bulky or fiber specimen in high resolution' and 'observation of potential distribution and electromotive force in semiconductor devices'.

  • PDF

Electrical Properties of a Single ZnO Nanowire in a four-probe Configuration (단일 ZnO 나노선 4단자 소자의 전기적 특성)

  • Kim, Kang-hyun;Kang, Hae-yong;Yim, Chan-young;Jeon, Dae-young;Kim, Hye-young;Kim, Gyu-Tae;Lee, Jong-Soo;Kang, Woun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1087-1091
    • /
    • 2005
  • Four-probe device of single ZnO nanowire was fabricated by electron beam lithography. Electrical characterizations in a two-probe and a four-probe configuration with a back-gate were carried out to clarify the relative contribution of the contact and the intrinsic part in a ZnO nanowire. I-V characteristic in four-probe measurement showed an ohmic behavior with a high conductivity, 100 S/cm, which was better than those of two-probe measurement by 10 times. At the same values of the current between two-probe and four-probe, the net voltage applied inside the nanowire were extracted with calculated voltages at the contact. Four-probe current-gate voltage characteristics showed bigger tendencies than those of two-probe measurement at low temperatures, indicating the reduced gate dependence in two-Probe measurements by the existence of the contact resistance.

Experimental Research of an ECR Heating with R-wave in a Helicon Plasma Source

  • Ku, Dong-Jin;An, C.Y.;Park, Min;Kim, S.H.;Wang, S.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.274-274
    • /
    • 2012
  • We have researched on controlling an electron temperature and a plasma collision frequency to study the effect of collisions on helicon plasmas. So, we have designed and constructed an electron cyclotron resonance (ECR) heating system in the helicon device as an auxiliary heating source. Since then, we have tried to optimize experimental designs such as a magnetic field configuration for ECR heating and 2.45GHz microwave launching system for its power transfer to the plasma effectively, and have characterized plasma parameters using a Langmuir probe. For improving an efficiency of the ECR heating with R-wave in the helicon plasma, we would understand an effect of R-wave propagation with ECR heating in the helicon plasma, because the efficiency of ECR heating with R-wave depends on some factors such as electron temperature, electron density, and magnetic field gradient. Firstly, we calculate the effect of R-wave propagation into the ECR zone in the plasma with those factors. We modify the magnetic field configuration and this system for the effective ECR heating in the plasma. Finally, after optimizing this system, the plasma parameters such as electron temperature and electron density are characterized by a RF compensated Langmuir probe.

  • PDF

Plasma Diagnosis of Ne:Xe, Ne:Ar Mixed Gases by Single Langmuir Probe in Inductively Coupled Plasma Light Source System (ICP 광원 시스템의 Ne:Xe, Ne:Ar 혼합가스의 단일탐침법을 이용한 플라즈마 진단)

  • Choi, Yong-Sung;Lee, Woo-Ki;Moon, Jong-Dae;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mechanism is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by Langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

Single-Particle Characterization of Municipal Solid Waste (MSW) Ash Particles Using Low- Z Particle Electron Probe X-ray Microanalysis (단일입자분석(Low-Z Particle Electron Probe X-ray Microanalysis)을 이용한 도시 소각재 입자의 특성분석)

  • Hwang Hee Jin;Kim Hye Kyeong;Ro Chul-Un
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.367-375
    • /
    • 2005
  • Low-Z particle Electron Probe X-ray Microanalysis was applied to characterize MSW fly- and bottom -ash particle samples originated from two municipal incinerators (denoted as A and B) in Korea. According to their chemical composition, many distinctive particle types were identified. In A fly ash, the major chemical species are carbon-rich, aluminosilicates and many particles are composed of as a mixture of $ CaCO_3$ and other chemical species such as $CaSO_4$ or $CaCl_2$. For B fly ash, Fe, iron oxide, NaCl and NaCl-containing particles are the most abundant. In bottom ash, A and B were composed of similar chemical species such as carbon-rich, Fe, iron oxide, $CaCO_3$, and aluminosilicates. It was demonstrated that the single-particle characterization using this low-Z particle EPMA technique provided detailed information on various types of chemical species in the MSW ash samples. In addition, the technique has advantage over conventional analytical techniques in the point that both crystalline and glass-like ash particles can be analyzed at the same time.

Single Particle Characterization of Aerosol Particles Collected at Jeju Island, Korea, During 'ACE-Asia' Intensive Observation Period, Using Low-Z Particle Electron Probe X-ray Microanalysis (Low-Z Particle Electron Probe X-ray Microanalysis법을 이용한 2001년 ACE-Asia 집중 측정 기간 중 제주도 고산에서의 입자상 물질의 특성분석)

  • An Yong Hoon;Kim HyeKyeong;Ro Chul-Un
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.811-821
    • /
    • 2004
  • Low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA) was applied to characterize aerosol particles collected at Gosan in Jeju island during an IOP (intensive observation period) for an international ACE-Asia project in April, 2001. Various types of atmospheric particles such as organics, carbon-rich, aluminosilicates, silicon oxide, sodium nitrate, sodium chloride, and ammonium sulfate were observed. The reacted sea salt particles such as sodium nitrate were the most abundantly encountered, but original sea salt particles were rarely observed. Since the Low-Z particle EPMA can provide quantitative information on the chemical composition of aerosol particles, many different particle types on the basis of their chemical compositions were observed and identified. In this study, it is demonstrated that the Low-Z particle EPMA can provide detailed information on the chemical compositions for the aerosol particles collected for six consecutive days in April, 2001, at Gosan super-site.