• Title/Summary/Keyword: Electron Dose Rate

Search Result 130, Processing Time 0.027 seconds

A study on radiation degradation of LDPE by using ESR (ESR을 이용한 저밀도 폴리에틸렌의 방사선 열화에 관한 연구)

  • Kim, Ki-Yup;Kim, Jin-Ah;Lee, Chung;Kim, Pyeong-Jong;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.473-476
    • /
    • 2004
  • This study has investigated radiation degradation of low density polyethylene(LDPE). Samples were irradiated using a $Co^{60}\;\gamma-ray$ and ray up to 800 kGy at a dose rate of 5 kGy/hr in the presence of air atmosphere at room temperature. After irradiation, free radical measurement of LDPE has established by electron spin resonance(ESR). Then, each sample was stored for 2 weeks. ESR measurement showed that free radical concentration(FRC) was increased with radiation dose and changed from alkyl, allyl radical to peroxy radical with time.

  • PDF

Oxidation of Carbon Monoxide by Pseudomonas carboxydohydrogena (Pseudomonas carboxydohydrogena에 의한 일산화탄소의 산화)

  • ;Hegeman, George
    • Korean Journal of Microbiology
    • /
    • v.21 no.1
    • /
    • pp.27-35
    • /
    • 1983
  • The stoichiometry between the consumption of CO and $O_2$ and the production of $CO_2(2CO+O_2{\rightarrow}2CO_2)$) showed that Pseudomonas carboxydohydrogena grows as a typical aerobic CO oxidizer with CO. The optimal concentration of CO for growth was found to be 30% in gas mixture with air. The initial buffer concentration of the culture medium did not affect the growth of this bacterium. P. carboxydohydrogena is an obligate aerobe and dose not use nitrate as a terminal electron acceptor. The CO dehydrogenase is an inducible and soluble enzyme. The reaction rate and stability were maximal at pH7.5, and the Arrhenius plot revealed an activation energy of 37.7kJ/mol (9.0 Kcal/mol). The crude enzyme used methylene blue, thionin, and toluylene blue as electron acceptors for the oxidation of CO to $Co_2$ under anaerobic conditions. It was found that water must be the source of the second oxygen atom for CO oxidation.

  • PDF

Variation of Effective SSD According to Electron Energies and Irradiated Field Sizes (전자선 에너지 및 조사야에 따른 유효선원 피부 간 거리 변화)

  • Yang, Chil-Yong;Yum, Ha-Yong;Jung, Tae-Sik
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.157-163
    • /
    • 1987
  • It is known that fixed source to skin distance (SSD) cannot be used when the treatment field is sloped or larger than the size of second collimator in electron beam irradiation and inverse square law using effective ssd should be adopted. Effective SSDs were measured in different field sizes in each 6, 9, 12, 15 and 18MeV electron energy by suing NELAC 1018D linear accelerator of Kosin Medical Center. We found important parmeters of effective SSD. 1. Minimum effective SSD was 58.8cm in small field size of $6\pm6cm$ and maximum effective SSD was 94.9cm in large field size of $25\pm25cm$, with 6MeV energy. It's difference was 36.1cm. The dose rate at measuring point was quite different even with a small difference of SSD in small field $(6\times6cm)$ and low energy (6 MeV). 2. Effective SSD increased with field size in same electron energy. 3. Effective SSDs gradually increased with the electron energies and reached maximum at 12 or 15 MeV electron energy and decreased again at 18MeV electron energy in each identical field size. And so the effective SSD should be measured in each energy and field size for practical radiotherapy.

  • PDF

Electron Microscopic Study on the Parafollicular Cells of the Thyroid Gland of the Head and Neck-Irradiated Rats (방사선이 흰쥐 갑상샘 소포곁세포에 미치는 영향에 대한 미세구조적 연구)

  • Kim, Young-Sik;Yang, Nam-Gil;Ahn, E-Tay;Ko, Jeong-Sik;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.22 no.2
    • /
    • pp.1-14
    • /
    • 1992
  • This experiment was performed to study the morphological responses of the parafollicular cells of rat following X-ray irradiation. Male rats were divided into normal and experimental groups. The head and neck region of the rat, under sodium thiopental anesthesia, was exposed to 3,000 rads or 6,000 rads of radiation in a single dose, respectively. The source was a Mitsubishi Linear Accelerator ML-4MV. The target to skin distance was 80 cm, and the dose rate was 200 rads/min. The rate of experimental groups were sacrificed on the 6th hour, 2nd and 6th day after X-ray irradiation. Pieces of the tissue taken from the thyroid gland were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde (0.1M Millonig's phosphate buffer, pH 7.3), and in 1% osmium tetroxide (0.1M Millonig's phosphate buffer, pH 7.3), and embedded in araldite mixture. The ultrathin sections stained with uranyl acetate and lead citrate were observed with JEM 100 CX-II electron microscope. The results were as follow; 1. Two types of the parafollicular cells, according to their electron densities, were found, i. e., light cells and dark cells. 2. Three types of the parafollicular cells, according to their sizes of secretory granules were found, i.e., small granule cells ($85nm{\pm}20.1;64{\sim}102nm$), medium granule cells ($120nm{\pm}26.5;77{\sim}179nm$), and large granule cells ($165nm{\pm}25.7;128{\sim}189nm$). 3. The differential ultrastructural changes of the cells according to their cell types, i.e., dark and light cell, or small, medium and large granule cells, were hardly observed in the time and dose range covered by this study. 4. The morphological changes of the parafollicular cells were not pronounced after exposure to 3,000 rads of X-ray. 5. Swollen cisternae of the granular endoplasmic reticulum and partial cytolysis were observed after exposure to 6,000 rads of X-ray. 6. Above results suggest that the parafollicular cells showed the alterations of mitochondrial and granular endoplasmic reticular swelling, and partial cytolysis, but only in doses of 6,000 rads.

  • PDF

Evaluation of Radiological Effects on the Aptamers to Remove Ionic Radionuclides in the Liquid Radioactive Waste

  • Minhye Lee;Gilyong Cha;Dongki Kim;Miyong Yun;Daehyuk Jang;Sunyoung Lee;Song Hyun Kim;Hyuncheol Kim;Soonyoung Kim
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2023
  • Background: Aptamers are currently being used in various fields including medical treatments due to their characteristics of selectively binding to specific molecules. Due to their special characteristics, the aptamers are expected to be used to remove radionuclides from a large amount of liquid radioactive waste generated during the decommissioning of nuclear power plants. The radiological effects on the aptamers should be evaluated to ensure their integrity for the application of a radionuclide removal technique. Materials and Methods: In this study, Monte Carlo N-Particle transport code version 6 (MCNP6) and Monte Carlo damage simulation (MCDS) codes were employed to evaluate the radiological effects on the aptamers. MCNP6 was used to evaluate the secondary electron spectrum and the absorbed dose in a medium. MCDS was used to calculate the DNA damage by using the secondary electron spectrum and the absorbed dose. Binding experiments were conducted to indirectly verify the results derived by MCNP6 and MCDS calculations. Results and Discussion: Damage yields of about 5.00×10-4 were calculated for 100 bp aptamer due to the radiation dose of 1 Gy. In experiments with radioactive materials, the results that the removal rate of the radioactive 60Co by the aptamer is the same with the non-radioactive 59Co prove the accuracy of the previous DNA damage calculation. Conclusion: The evaluation results suggest that only very small fraction of significant number of the aptamers will be damaged by the radioactive materials in the liquid radioactive waste.

Clinical outcomes and prognostic factors in patients with mycosis fungoides who underwent radiation therapy in a single institution

  • Jang, Bum-Sup;Kim, Eunji;Kim, Il Han;Kang, Hyun-Cheol;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.36 no.2
    • /
    • pp.153-162
    • /
    • 2018
  • Purpose: We aimed to evaluate clinical outcomes including progression-free survival (PFS), overall survival (OS), partial response, and complete response in patients who underwent radiation therapy (RT) for mycosis fungoides (MF). Also, we sought to find prognostic factors for clinical outcomes. Materials and Methods: Total 19 patients confirmed with MF between 1999-2015 were retrospectively reviewed. Clinical and treatment characteristics, clinical outcomes, and and toxicities were analyzed. Results: Eleven patients were treated with total skin electron beam radiotherapy (TSEBT) and 8 patients with involved field radiation therapy (IFRT) with median dose of 30 Gy, respectively. The median time interval from diagnosis to RT was 2.6 months (range, 0.4 to 87.3 months). The overall response rate was 100%; 11 patients (57.9%) had a complete response and 8 patients (42.1%) a partial response. The presence of positive lymph node at the time of consultation of RT was associated with lower OS (p = 0.043). In multivariate analysis, PFS was significantly lower for patients with increased previous therapies experienced following RT (p = 0.019) and for patients showing PR during RT (p = 0.044). There were no reported grade 3 or more skin toxicities related with RT. Conclusion: Both IFRT and TSEBT are effective treatment for MF patients. Patients with short disease course before RT or complete response during RT are expected to have longer PFS. Positive lymph node status at the initiation of RT was associated woth poor OS, suggesting other treatment modalities such as low-dose RT for patients with low life-expectancy.

Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process (원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법)

  • Son, Bong-Ho;Lim, Bong-Su;Oa, Seong-Wook;Lee, Byung-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

Electron Dose Measurement with Polycarbonate Film Dosimeter

  • Yoo, Young-Soo
    • Nuclear Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.9-17
    • /
    • 1976
  • Dosimetrical properties of polycarbonate film for high-level dosimetry of electrons have been examined. Polycartonate film of 0.1mm in thickness was chosen for this purpose. It can cover the dose range of 1.0-130 Mrad and the measurable range can be extended up to 200 Mrad by using calibration curve. The measurement error was within 3.5%. The radiation induced optical density at 330nm shows rapid initial fading of 7-l3n for one day after irradiation at room temperature and subsequent fading rate is very small, about 0.6% per day. The fading depends on the absorbed dose, storage temperature, and wavelengths. The effects of storage time and temperature during and after irradiation of this film are presented. For practical dosimetry, it is necessary to stabilize the induced optical density by storing the irradiated film for a day or by heat treatment at 10$0^{\circ}C$ for an hour.

  • PDF

Monte carlo estimation of activation products induced in concrete shielding around electron linac used in an X-ray container inspection system (X-ray 컨테이너 화물검색시스템의 전자선형가속기 주변 콘크리트 차폐벽 내 방사화생성물에 대한 몬테카를로법 평가)

  • Cho, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1035-1039
    • /
    • 2010
  • Activation products generated by photoneutrons in concrete shielding wall around electron linac were estimated for a high energy X-ray container cargo inspection system. Monte carlo code, MCNPX2.5.0 was used for reference system of 9MeV fixed type dual-direction container cargo inspection system installed at major harbors in Korea. Activation products inventory generated by photoneutron (n,$\gamma$) reaction are estimated, and then radiation dose rate is calculated from the results.

Distribution of X-ray Strength in Exposure Field Caused by Heel Effect (양극의 경사각 효과에 따른 조사야 X-선 강도 분포)

  • Jang, Keun-Jo;Kim, Nam-Hun;Lee, Jun-Haeng;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • When negative electron in x-ray tube is accelerated in to a high speed and then the currency of the electron is blocked by the target, x-ray happens by the conversion of the energy. The real area where the fast accelerated electron collides to a target area is called actual focal spot. When the string focused size is observed at the central ray side, where the direction x-ray comes out, the size seems to be reduced. This focus is called effective focal spot. According to radiation angle of x-rays tube, the degree of the negative pole side presents higher value than inclination, the amount of exposed radiation that patient receives differs by the angle of positive pole, which means effective focal spot is the variable. This paper presents the correlation between size of effective focal spot and amount of exposed radiation to the patient by it, and effective research for homogenized dose dispersion by the size of effective focal spot. In conclusion, following the focal size, effective range which was -8cm ~ 0 cm on average, was found and average dose rate was 0.019 R/min. Through this range, for patients with small radiation exposure, image with good density and resolution in aspect of diagnosing will be able to be obtained.