• Title/Summary/Keyword: Electron Detector

Search Result 264, Processing Time 0.029 seconds

Analysis of Multiple Pesticide Residues in Apples and Pears Using Gas-Liquid Chromatography (Gas-Liquid Chromatography를 이용한 사과 및 배 중의 농약 다성분 잔류분석법)

  • Park, Ju-Hwang;Kim, Taek-Kyum;Oh, Chang-Hwan;Kim, Jeong-Han;Lee, Young-Deuk;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.3
    • /
    • pp.148-157
    • /
    • 2004
  • A rapid analytical method was developed to determine multiple pesticide residues in apples and pears using gas-liquid chromatography (GLC). The samples were extracted with water-miscible solvents and purified by cleanup procedures serially comprising liquid-liquid partition and solid-phase extraction (SPE). Each analyte was separated and determined by a high-resolution GLC equipped with electron-capture detector (ECD) and nitrogen-phosphorous detector (NPD). A total of 196 pesticides, which were previously classified into 5 groups each for ECD and NPD based on their retention behaviors on the capillary column and responses to the detector, were subjected to the recovery experiment. In compliance with the analytical criteria, 70 to 120% of recovery and less than 20% relative standard deviation the proposed method could be successfully applied to analyze 136 and 133 pesticide residues in apples and pears, respectively, which enabled not only rapid screening but quantitation of the residues. Even though less reliability was resulted from unacceptable recovery range, rest of pesticides including 43 and 45 analyzes in apples and pears, could be also detected for their identity. The proposed method fliled to cover 17 and 18 pesticides for apples and pears, which mostly showed high polarity or heat-lability but could be suitable far fast surveilance or monitoring of fruit harvests.

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.

A Study on Neutron Resonance Energy of Tantalum by 46-MeV Electron Linac TOF Method (46-MeV 전자선형가속기의 TOF 방법을 이용한 탄탈의 중성자 공명 에너지 분석에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.245-249
    • /
    • 2013
  • Neutron sources from photonuclear reaction with 46-MeV electron linear accelerator at Research Reactor Institute, Kyoto University used for resonance energy measurement of natural tantalum. BGO($Bi_4Ge_3O_{12}$) scintillation detectors used for measurement of the prompt gamma ray from the natural tantalum sample. The BGO spectrometer was composed geometrically as total energy absorption detector. The electric signal from the spectrometer was analyzed for TOF(Time-of-Flight) spectrum which is used identification of neutron capture resonance energy. In this study, the neutron energy region is from 1 to 200 eV, because of strong X-ray effect produced photonuclear reaction in Ta target, the measurement was performed to below 1 keV energy region. The resonance energy was compared with the evaluated values(ENDF/B-VI, Mughabghab). All of the resonances from 4.28 ~ 200 eV were seen in the present measurement except 144.3 eV resonance.

Measurement of Energy Dependent Differential Neutron Capture Cross-section of Natural Sm by Using a Continuous Neutron Flux below (연속에너지 중성자에 대한 천연 Sm의 중성자 포획단면적 측정)

  • Yoon, Jungran
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.337-341
    • /
    • 2016
  • We measured the neutron capture cross-section of natural Sm(n,${\gamma}$) reaction in the energy regions from 0.003 to 10 eV. The 46-MeV electron linear accelerator of Research Reactor Institute, Kyoto University was used for generating a continuous neutron source. The neutron time-of-flight method was adopted for energy measurement. An assembly of BGO($Bi_4Ge_3O_{12}$) scintillators composed of 12 pieces of BGO crystals measured prompt gamma rays from Sm(n,${\gamma}$) reaction. The BGO assembly was located at a distance of $12.7{\pm}0.02m$ from the neutron source. In order to determine the neutron flux impinging on the Sm, the $^{10}B(n,{\alpha}{\gamma})^7Li$ standard cross-section were used. Natural Sm(n,${\gamma}$) reaction measurement result of the neutron capture cross-section was compared with the results of evaluation of the BROND-2.2 and the previous experimental data of J. C. Chou and V. N. Kononov.

Growth of zinc oxide thin films by oxygen plasma-assisted pulsed laser deposition

  • Pak, Sang-Woo;Suh, Joo-Young;Lee, Dong-Uk;Kim, Eun-Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.208-208
    • /
    • 2010
  • Zinc oxide (ZnO) is a functional material with interesting optical and electrical properties, a wide band gap (more than 3.3 eV), a high transmittance in the visible light region, piezoelectric properties, and a high n-type conductivity. This material has been investigated for use in many applications, such as transparent electrodes, blue light-emitting diodes, and ultra-violet detector. ZnO films grown under low oxygen pressure by thin film deposition methods show low resistivity and large free electron concentration. Therefore, reducing the background carrier concentration in ZnO films is one of the major challenges ahead of realizing high-performance ZnO-based optoelectronic devices. In this study, we deposited ZnO thin films on sapphire substrates by pulsed laser deposition (PLD) with employing an oxygen plasma source to decrease the background free-electron concentration and enhance the crystalline quality. Then, the substrate temperature was varied between 200 'C to 900 'C The vacuum chamber was initially evacuated to a pressure of $10^{-6}$ Torr, and then a pure $O_2$ gas was introduced into the chamber and the pressure during deposition was maintained at $10^{-2}$ Torr. Crystallinity and orientation of ZnO films were investigated by X-ray diffraction (XRD). The film surface was analyzed with atomic force microscope (AFM). And electrical properties were measured at room temperature by Hall measurement.

  • PDF

Transport parameters in a-Se:As films for digital X-ray conversion material (디지털 X-선 변환물질 a-Se:As의 수송변수)

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.51-55
    • /
    • 2006
  • The effects of Asaddition in amorphous selenium(a-Se) films for digital X-ray conversion material have been studied using the moving photocarrier grating(MPG) technique. This method utilizes the moving interference pattern generated by the superposition of the two frequency shifted laser beams for the illumination of the sample. This moving intensity grating induces a short circuit current, j$_{sc}$ in a-Se:As film. The transport parameters of the sample are extracted from the grating-velocity dependent short circuit current induced in the sample along the modulation direction. The electron and hole mobility, and recombination lifetime of a-Se films with arsenic(As) additions have been obtained. We have found an Increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with X-ray sensitivity for a-Se:As device. The fabricated a-Se(0.3% As) device film exhibited the highest X-ray sensitivity out of 5 samples.

  • PDF

X-ray / gamma ray radiation shielding properties of α-Bi2O3 synthesized by low temperature solution combustion method

  • Reddy, B. Chinnappa;Manjunatha, H.C.;Vidya, Y.S.;Sridhar, K.N.;Pasha, U. Mahaboob;Seenappa, L.;Sadashivamurthy, B.;Dhananjaya, N.;Sathish, K.V.;Gupta, P.S. Damodara
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1062-1070
    • /
    • 2022
  • In the present communication, pure and stable α-Bismuth Oxide (Bi2O3) nanoparticles (NPs) were synthesized by low temperature solution combustion method using urea as a fuel and calcined at 500℃. The synthesized sample was characterized by using powder X-ray Diffraction (PXRD), Scanning Electron Microscopy (SEM), Energy dispersive X-ray analysis (EDAX), Transmission Electron Microscopy (TEM), Fourier Transform Infrared Spectroscopy (FTIR) and UV-Visible absorption spectroscopy. The PXRD pattern confirms the formation of mono-clinic, stable and low temperature phase α-Bi2O3. The direct optical energy band gap was estimated by using Wood and Tauc's relation which was found to be 2.81 eV. The characterized sample was studied for X-ray/gamma ray shielding properties in the energy range 0.081-1.332 MeV using NaI (Tl) detector and multi channel analyzer (MCA). The measured shielding parameters agrees well with the theory, whereas, slight deviation up to 20% is observed below 356 keV. This deviation is mainly due to the influence of atomic size of the target medium. Furthermore an accurate theory is necessary to explain the interaction of X-ray/gamma ray with the NPs.The present work opens new window to use this facile, economical, efficient, low temperature method to synthesize nanomaterials for X-ray/gamma ray shielding purpose.

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF

A Study of Current Status on Pesticide Residues in Commercial Dried Agricultural Products (서울시 유통 건조농산물 중의 농약잔류 실태 연구)

  • Kim, Bog-Soon;Park, Seoung-Gyu;Kim, Mi-Sun;Cho, Tae-Hee;Han, Chang-Ho;Jo, Han-Bin;Choi, Byung-Hyun;Kim, Sung-Dan
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.114-121
    • /
    • 2007
  • The purpose of this study was to investigate 253 kinds of pesticide residues in 58 commercial dried agricultural products in Seoul. The determinations of the pesticide residues were performed using multiresidue methods and were carried out by a gas chromatography-nitrogen phosphorus detector (GC-NPD), an electron capture detector ($GC-{\mu}ECD$), a mass spectrometry detector (GC-MSD) and high performance liquid chromatography-ultraviolet detector (HPLC-UV), and a fluorescence detector (HPLC-FLD). The pesticide residue detection rate in the commercial dried agricultural products was 24.1% (14 of 58 samples). Twelve pesticide residues without maximum residue limits (MRLs) were detected. In the vegetable groups, the frequency of pesticide residues was found to be in the increasing order of dried fruiting vegetables > dried leafy vegetables > dried stalk and stem vegetables. The pesticides used on dried red pepper in the dried fruiting vegetables were varied (7 kinds) and numerous (4 of 8 samples). The pesticide types detected in the commercial dried agricultural products were in the order of pyrethroid > organochloride > organophosphorus and insecticide > fungicide > herbicide ${\cdot}$ nematicide. The primary pyrethroid pesticide detected was cypermethrin. According to the producing areas of products, large numbers of pesticide residues were found in the order of Korea, China, North Korea, USA, and Vietnam.

Analysis of Half-life Time and Residual Concentration of Ethalfluralin Herbicide in Soils (토양 중 제초제 Ethalfluralin의 잔류 농도와 반감기 분석)

  • Han, Seong Soo;Rim, Yo Sup;Kim, Il Kwang
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.168-178
    • /
    • 1997
  • The optimum conditions for the residual analysis of the ethalfluralin herbicide on soils were investigated and the residues in soils were determined by gas chromatography with electron capture detector(GC-ECD). The soil samples extracted with methanol and dichloromethane and concentrated. The concentrated phase were redissolved with toluene and analyzed with GC-ECD after separated by cyanosilica gel Sep-Pak cartridge. From the standard addition experiments with 0.1 and 1.0ppm, the average recoveries were 92.8~101.2% and the detection limit was 0.004ppm. The half-life time of ethalfluralin in the soil(A) was 35 days in the laboratory and 7.2 days in the field test whereas it was 45 days and 9.7 days for each in case of soil(B).

  • PDF