• Title/Summary/Keyword: Electron Detector

Search Result 266, Processing Time 0.037 seconds

Electrochemical Properties of Self-Assembled Viologen Monolayer Using QCM (QCM을 이용한 자기조립화된 Viologen 단분자막의 전기화학적 특성 연구)

  • Ock, Jin-Young;Park, Sang-Hyun;Kim, Byoung-Sang;Shin, Hoon-Kyu;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1520-1522
    • /
    • 2003
  • Molecular self-assembled of surfactant viologen are of recent interest because they can from functional electrodes as well as micellar assemblies, which can be Profitably utilized for display devices, photoelectrochemical studies and electrocatalysis as electron acceptor or electron mediator. Fromherz et al studied the self-assembly of thiol and disulfide derivatives of viologens bearing long n-alkyl chains on Au electrode surface. The electrochemical behavior of self-assembled viologen monolayer has been investigated with QCM, which has been known as nano-gram order mass detector. The self-assembly process of viologen was monitored using resonant frequency (${\Delta}$F) and resonant resistance (R). The redox process of viologen was observed with resonant frequency (${\Delta}$F).

  • PDF

Gas Chromatographic Analysis of TDI, MDI and HDI Using 2-Chlorobenzyl Alcohol and 2,4-Dichlorobenzyl Alcohol Derivatives (2-클로로벤질 알코올 및 2,4-디클로로벤질 알코올 유도체를 이용한 TDI, MDI 및 HDI의 가스크로마토그래피 분석)

  • Yun, Ju-Song;Park, Jun-Ho;Lee, Kang-Myoung;Choi, Hong-Soon;Cho, Young-Bong;Koh, Sang-Baek;Cha, Bong-Suk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.222-232
    • /
    • 2006
  • Objectives: The objective of this study was to propose the total isocyanate analytical method which involves derivation of 2,4-toluene diisocyanate(2,4-TDI), 2,6-toluene diisocyanate(2,6-TDI), 4,4'-methylenediphenyl diisocyanate(4,4'-MDI) and 1,6-hexamethylene diisocyanate(1,6-HDI) using 2-chlorobenzyl alcohol(2-CBA) or 2,4-dichlorobenzyl alcohol(2,4-DCBA), and analyzing of hydrolysate of the synthesized urethane with the gas chromatography(GC)/flame ionization detector(FID), GC/pulsed discharge ionization detector-electron capture detector(PD-ECD) and GC/mass selective detector(MSD). Methods: Urethanes were synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI to 2-CBA or 2,4-DCBA. Urethanes was verified by TLC, HPLC/UVD and GC/MSD. For field application, the most suitable condition that 2-CBA coated in glass fiber filter removed completely and urethanes were not removed was searched. 2-CBA generated from hydrolysis of urethanes according to hydrolysis conditions. Diisocyanates were collected on field air and analyzed. Results: Urethanes which were white and solid phase synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI, 1,6-HDI and 2-CBA or 2,4-DCBA. And urethanes were verified by TLC, HPLC/UVD and GC/MSD. The most suitable conditions to remove 2-CBA coated in glass fiber filter were $87^{\circ}C$ and 20 mmHg and urethanes were not removed under same condition. Hydrolysis yields of urethanes were 99 % to 111 %. 2-CBA, the hydrolysate of urethanes was analyzed by GC/FID, GC/PD-ECD and GC/MSD. Conclusions: Simultaneous analysis of 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI deriving with 2-CBA and 2,4-DCBA, along with a total isocyanate analysis, was feasible with GC/FID, GC/PD-ECD and GC/MSD. This result will be a guide of further study on total isocyanate analysis.

Characteristics of Detectors for Measurements of Photon Depth Doses in Build-Up Region (선량보강(Build-up) 영역에서의 광자선 깊이선량률 측정을 위한 검출기의 특성 비교)

  • Kang Sei-Kwon;Park Suk Won;Oh Do Hoon;Park Hee Chul;Kim Su Ssan;Bae Hoonsik;Cho Byung Chul
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.77-81
    • /
    • 2005
  • To determine the appropriate method out of various available methods to measure build-up doses, the measurements and comparisons of depth doses of build-up region including the surface dose were executed using the Attix parallel-plate ionization chamber, the Markus chamber, a cylindrical ionization chamber, and a diode detector. Based on the measurements using the Attix chamber, discrepancies of the Markus chamber were within $2\%$ for the open field and increased up to $3.9\%$ in the case of photon beam containing the contaminant electrons. The measurements of an cylindrical ionization chamber and a diode detector accord with those of the Attix chamber within $1.5\%\;and\;1.0\%$ and after those detectors were completely immersed in the water phantom. The results suggest that the parallel-plate chamber is the best choice to measure depth doses in the build-up region containing the surface, however, using cylindrical ionization chamber or diode detector would be a reasonable choice if no special care is necessary for the exact surface dose.

  • PDF

Monitoring and risk assessment of pesticide in school foodservice products in seoul, Korea (서울지역 학교급식 식재료의 잔류농약 위해성 평가)

  • Seo, Young-Ho;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.69-74
    • /
    • 2014
  • We tested for residual pesticide levels in school foodservice agricultural products in Seoul, Korea from 2010 to 2012. A total of 316 samples of 23 different types of agricultural products were analyzed via gas chromatography-nitrogen phosphate detector (GC-NPD), an electron capture detector (GC-${\mu}ECD$), a mass spectrometry detector (GC-MSD), and a high performance liquid chromatography-ultraviolet detector (HPLC-UV). We used multi-analysis methods to analyze 185 different pesticide types. Among the selected agricultural products, residual pesticides were detected in 26 samples (8.2%), of which 6 samples (1.9%) exceeded the Korea Maximum Residue limits (MRLs). We detected pesticide residue in more than 65% of the Chwinamul, while 6 among 9 analyzed samples contained pesticide residue, and 1 sample exceeded the Korea MRLs. Among the 185 kinds of pesticides that we have tested, 18 were detected, while 7 of them were detected more than twice. Data obtained were then used for estimating the potential health risks associated with the exposures to these pesticides. The most critical commodity is carbofuran in the perilla leaves, which has contributed 3.8% to the hazard index (HI). These results showed that the detected pesticides could not be considered as a serious public health problem. Nevertheless, constant supervision is recommended.

Evaluation of Residual Pesticides in Fresh Ginseng Collected in Seoul

  • Kim, Tae-Rang;Park, Ki-Hwan;Jang, Mi-Ra;Choi, Young-Hee;Kim, Eun-Hee;Choi, Chae-Man;Park, Sung-Kyu;Yu, In-Sil;Hwang, In-Sook;Han, Ki-Young;Kim, Moo-Sang;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • This study was performed to analyze 48 kinds of pesticide residues using gas chromatography (GC)/nitrogen phosphorous detector, GC/micro electron capture detector, GC/mass selective detector, and high performance liquid chromatograph/diode array detector in 186 fresh ginseng samples collected in the Seoul area from 2010 to 2011. Fresh ginseng dietary intakes were estimated using the data from the 2009 Korea National Health and Nutrition examination survey. Residual pesticides were detected in 79 samples (42.5%) with eight different fungicides. Only 20 samples (10.8%) exceeded the maximum residue limits (MRLs) for pesticides registered by the Korea Food & Drug Administration. Among them, tolclofos-methyl residues (10.2%) exceeded the MRL for fresh ginseng in 18 ginseng seedlings and one of the two-year old fresh ginseng plants, and the residual level in just one ginseng seedling violated the MRL for pyrimethanil. The results showed that residual pesticides levels in marketable fresh ginseng around Seoul were relatively safe. The percent acceptable daily intake (%ADI) was calculated using pesticide residues in fresh ginseng and dietary intakes of fresh ginseng. The risk caused by pesticide residues in fresh ginseng was very low.

Molecular Level Detection of Heavy Metal Ions Using Atomic Force Microscope (원자간인력현미경을 이용한 분자수준의 중금속 이온 검출)

  • Kim, Younghun;Kang, Sung Koo;Choi, Inhee;Lee, Jeongjin;Yi, Jongheop
    • Clean Technology
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • A metal ion detector with a submicron size electrode was fabricated by field-induced AFM oxidation. The square frame of the mesa pattern was functionalized by APTES for the metal ion detection, and the remaining portion was used as an electrode by the self-assembly of MPTMS for Au metal deposition. The conductance changed with the quantity of adsorbed copper ions, due to electron tunneling between the mobile and surface electrodes. The smaller electrode has a lower limit of detection due to the enhancement in electron tunneling through metal ions that are adsorbed between the conductive-tip (mobile) and the surface (fixed) electrode. This two-electrode system immobilized with different functional groups was successfully used in the selective adsorption and detection of target materials.

  • PDF

Influence of Ne-Xe Gas Mixture Ratio on the Extreme Ultraviolet (EUV) Emission Measurement from the Coaxially Focused Plasma

  • Lee, Sung-Hee;Hong, Young-June;Choi, Duk-In;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.220-220
    • /
    • 2011
  • The Ne-Xe plasmas in dense plasma-focus device with coaxial electrodes were generated for extreme ultraviolet (EUV) lithography. The influence of gas mixture ratio, Ne-Xe (1, 10, 15, 20, 25, 30, 50%) mixture gas, on EUV emission measurement, EUV intensity and electron temperature in the coaxially focused plasma were investigated. An input voltage of 4.5 kV was applied to the capacitor bank of 1.53mF and the diode chamber was filled with Ne-Xe mixture gas at a prescribed pressure. The inner surface of the cylindrical cathode was lined by an acetal insulator. The anode was made of tin metal. The EUV emission signal of the wavelength in the range of 6~16 nm has been detected by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission line was also detected by the composite-grating spectrometer of the working wavelength range of 200~1100 nm (HR 4000CG). The electron temperature is obtained by the optical emission spectroscopy (OES) and measured by the Boltzmann plot with the assumption of local thermodynamic equilibrium (LTE).

  • PDF

Measurement of EUV Emission and its Plasma Parameters Generated from the Coaxial Plasma Focus of Mather and Hypocycloidal Pinched Electrodes

  • Lee, Sung-Hee;Lee, Kyung-Ae;Hong, Young-June;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.332-332
    • /
    • 2011
  • The extreme ultraviolet (EUV) radiation, whose wavelength is from 120 nm down to 10 nm, and the energy from 10 eV up to 124 eV, is widely utilized such as in photoelectron spectroscopy, solar imaging, especially in lithography and soft x-ray microscopy. In this study, we have investigated the plasma diagnostics as well as the debris characteristics between the two types of dense plasma focusing devices with coaxial electrodes of Mather and hypocycloidal pinch (HCP), respectively. The EUV emission intensity, electron temperature and plasma density have been investigated in these cylindrical focused plasma along with the debris characteristics. An input voltage of 5 kV has been applied to the capacitor bank of 1.53 uF and the diode chamber has been filled with Ar gas at pressure ranged from 1 mTorr and 180 mTorr. The inner surface of the cathode was covered by polyacetal insulator. The central anode electrode has been made of tin. The wavelength of the EUV emission has been measured to be in the range of 6~16 nm by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission has also been measured by the spectrometer with the wavelength range of 200~1,100 nm. The electron temperature and plasma density have been measured by the Boltzmann plot and Stark broadening methods, respectively, under the assumption of local thermodynamic equilibrium (LTE).

  • PDF

The Effects of Metal Plate loaded on TLD chip in 6 MV Photon and 6 MeV Electron Beams (6 MV 광자선과 6 MeV 전자선 하에서 TLD 기판 위에 얹힌 금속 박막의 효과)

  • Kim, Sookil;Byungnim Min
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • There is necessity for making a smaller and more sensitive detector in small field sizes. This report assesses the suitability of metal-loaded thermoluminescent dosimeters for this purpose. Measurements were performed in the 6 MV photon and 6 MeV electron beams of a medical linear accelerator with LiF thermoluminescence dosimeters (TLD-100) embedded in solid water phantom. TLD-100 chips(surface area 3.2 $\times$ 3.2 $\textrm{mm}^2$) loaded with a metal plate(Tin or gold respectively) were used to enhance dose readings to TLD-100. Surface dose was measured for field size 10 $\times$ 10 $\textrm{cm}^2$ and 100 em SSD. Measurements have been made of the enhanced signal intensity and good linearity for absorbed dose with each metal. Using a 1 mm each metal on TLD-l00 in the beam increased the surface dose to 14% and 56% respectively for 6MV photon. In the case of 6 MeV electron, gold plate enhanced the TL response to 13%, but there is no difference for tin plate. The specific dose response of TLD-100 with thin metal plate increases with electron concentration of metal film, this is most likely due to increased electron scattered from the additional material with electron density higher than TLD-100. This emphasizes the role of TL dosimeters with metal as amplified dosimeters for therapeutic high energy x-ray beams. Due to the enhanced dose reading of TLD-100 with metal plate, it could be possible to develop smaller TL dosimeter with high sensitivity.

  • PDF

Integrated Radiometric Signal Modeling for High Resolution Earth Observation Satellite Camera (고해상도 지구관측위성 카메라의 복사신호량에 대한 통합적 모델링)

  • Jang, Hong-Sul;Jung, Dae-Jun;Youk, Young-Chun;Lee, Seung-Hoon
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.82-87
    • /
    • 2008
  • In this study, the radiometric signal modeling is performed for the high resolution earth observation system in visible spectral range from space. The medeling includes solar radiation as a source of the radiometric energy, atmosphere and surface albedo of earth, and the spaceborne camera characteristics for the integrated modeling. The final output of the radiometric modeling is the number of electron produced by the detector of electro-optical camera.

  • PDF