• 제목/요약/키워드: Electron

검색결과 21,715건 처리시간 0.043초

전자현미경의 전자원 (Electron sources for electron microsocpes)

  • 조복래
    • 진공이야기
    • /
    • 제2권2호
    • /
    • pp.24-28
    • /
    • 2015
  • The brightness of an electron source, along with the aberrations of an objective lens, determines the image resolution and beam current on samples, which are two important parameters for evaluating the performance of an electron microscope. Here we introduce thermal electron source, Schottky emitter and cold field electron emitter. Thermal electron source is the cheapest and stable electron source but it has the lowest brightness. Schottky emitter is 10000 times brighter than tungsten thermal electron source, but requires ultrahigh vacuum operating condition. Cold field electron emitter is 10 times brighter than Schottky emitters, but it is rather unstable and its operation requires most stringent vacuum condition, hindering its widespread use.

고주파 유도결합 플라즈마의 전자에너지 분포함수 특성에 관한 연구 (A Study on the characteristics of Electron Energy Distribution function of the Radio-Frequency Inductively Coupled Plasma)

  • 황동원;하장호;전용우;최상태;이광식;박원주;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.131-133
    • /
    • 1998
  • Electron temperature, electron density and electron energy distribution function were measured in Radio-Frequency Inductively Coupled Plasma(RFICP) using a probe method. Measurements were conducted in argon discharge for pressure from 10 mTorr to 40 mTorr and input rF power from 100W to 600W and flow rate from 3 sccm to 12 sccm. Spatial distribution of electron temperature, electron density and electron energy distribution function were measured for discharge with same aspect ratio (R/L=2). Electron temperature was found to depend on pressure, but only weakly on power. Electron density and electron energy distribution function strongly depended on both pressure and power. Electron density and electron energy distribution function increased with increasing flow rate. Radial distribution of the electron density and electron energy distribution function were peaked in the plasma center. Normal distribution of the electron density, electron energy distribution function were peaked in the center between quartz plate and substrate. These results were compared to a simple model of ICP, finally, we found out the generation mechanism of Radio-Frequency Inductively Coupled Plasma.

  • PDF

몬테칼로 방법을 사용한 HgCdTe에서의 전자 전송 특성에 관한 연구 (A study on the electron transport properties in HgCdTe using monte carlo method)

  • 유상동;곽계달
    • 전자공학회논문지D
    • /
    • 제35D권2호
    • /
    • pp.40-51
    • /
    • 1998
  • Electron transport properties are investigated by Monte Carlo simulation in n-HgCdTe. The material is easily degenerated at low temperature or being slightly doped, and is characterized by small band gap and large nonparabolic factor. The degeneracy is incorporated in the Monte Carlo simulation by taking into account the electron-electron scattering and the pauli exclusion principle. In the conventional method, however, the electron-electron scattering rate was developed under the assumption of parabolic conduction band. A new formulation of the electron-electron scattering rate is develop considering the band nonparabolicity and overlap integral. The electron-electron scattering effects on the electron distribution,impact ionization coefficienty, electron temperature, drift velocity and electron energy are presented.

  • PDF

주사전자현미경용 전자검출기의 설계 및 제작 (Design and Manufacture of an Electron Detector for Scanning Electron Microscope)

  • 전종업;김지원
    • 한국정밀공학회지
    • /
    • 제25권4호
    • /
    • pp.53-60
    • /
    • 2008
  • Electron detectors used in scanning electron microscope accept electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. Electron detector is one of the key components dominating the performance of scanning electron microscope so that the development of electron detectors having high performance is indispensable to acquire high quality images using scanning electron microscope. In this paper, we designed and manufactured an electron detector and conducted a couple of image capture experiments using it. In particular, scintillator which generates light photons when it is struck by high-energy electrons was manufactured and experimental studies on the optimization of manufacturing condition was carried out. From experiments to evaluate the performance of our detector, it was verified that the performance of our detector is equivalent to or better than that of the conventional one.

주사 전자 현미경에서 전자빔 프르브 생성 (Creation of Electron Beam Probe in Scanning Electron Microscopy)

  • 임선종;이찬홍
    • 한국공작기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.52-57
    • /
    • 2008
  • Most of the electrons emitted from the filament, are captured by the anode. The portion of the electron current that leaves the gun through the hole in the anode is called the beam current. Electron beam probe is called the focused beam on the specimen. Because of the lenes and aperture, the probe current becomes smaller than the beam current. It generate various signals(backscattered electron, secondary electron) in an interaction with the specimen atoms. Backscattered electron provide an useful signal for composition and local specimen surface inclination. Secondary electron is used far the formation of surface imagination. The steady electron beam probe is very important for the imagination formation and the brightness. In this paper, we show the results of developed elements that create electron beam probe and the measured beam probe in various acceleration voltages by Faraday cup. These data are used to analysis and improve the performance of the system in the development.

Effect of bounce resonance heating on Electron Energy Distribution Function in a small Inductively Coupled Plasma

  • 정진욱;서상훈;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.208-208
    • /
    • 1999
  • It is found that with increasing power, the measured electron energy distribution by Langmuir probe evolves into a Druyvesteyn-like electron energy distribution in the low-pressure regime of 1mTorr in a small inductively coupled plasma. Electron bounce resonance is introduced to explain the transition of the electron energy distribution against the rf power, The energy diffusion coefficients which determine the shape of the electron energy distribution in elastic range are calculated with and without electron bounce resonance. This electron energy distribution transition is well explained by the electron bounce resonance.

  • PDF

Characteristics of Electron Beam Extraction in Large Area Electron Beam Generator

  • Woo, Sung-Hun;Lee, Hong-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.10-14
    • /
    • 2004
  • A large area electron beam generator has been developed for industrial applications, for example, waste water cleaning, flue gas treatment, and food pasteurization. The operational principle is based on the emission of secondary electrons from the cathode when ions in the plasma contact the cathode, which are accelerated toward the exit window by the gradient of the electric potential. Conventional electron beam generators require an electron beam scanning mechanism because a small area thermal electron emitter is used. The electron beam of the large area electron beam generator does not need to be scanned over target material because the beam area is considerable. We have fabricated a large area electron beam generator with peak energy of 200keV, and a beam diameter of 200mm. The electron beam current has been investigated as a function of accelerating voltage and distance from the extracting window while its radial distribution in front of the extracting window has been also measured.

The Effects of Electron Beam Exposure Time on Transmission Electron Microscopy Imaging of Negatively Stained Biological Samples

  • Kim, Kyumin;Chung, Jeong Min;Lee, Sangmin;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • 제45권3호
    • /
    • pp.150-154
    • /
    • 2015
  • Negative staining electron microscopy facilitates the visualization of small bio-materials such as proteins; thus, many electron microscopists have used this conventional method to visualize the morphologies and structures of biological materials. To achieve sufficient contrast of the materials, a number of imaging parameters must be considered. Here, we examined the effects of one of the fundamental imaging parameters, electron beam exposure time, on electron densities generated using transmission electron microscopy. A single site of a negatively stained biological sample was illuminated with the electron beam for different times (1, 2, or 4 seconds) and sets of micrographs were collected. Computational image processing demonstrated that longer exposure times provide better electron densities at the molecular level. This report describes technical procedures for testing parameters that allow enhanced evaluations of the densities of electron microscopy images.

Electron Donor와 Electron Acceptor의 농도가 사염화탄소의 생물분해에 미치는 영향 (Effects of Electron Donor and Electron Acceptor on Biodegradation of $CCl_4$)

  • 배우근
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 1991년도 춘계학술대회 학술대회 프로그램
    • /
    • pp.8-12
    • /
    • 1991
  • 탈질 박테리아를 이용한 사염화탄소의 분해 실험에서 electron donor의 공급이 중단되면 사염화탄소의 제거율이 낮아지고, 반면 electron acceptor의 주입이 중단되면 제거율이 높아졌다. 사염화탄소의 제거시 클로로폼이 생산되어 사염화탄소가 환원되고 있음을 보여 주었다. 이 결과는 사염화탄소가 일종의 electron acceptor로 작용하면서 전자를 얻기 위해 세포 내의 다른 electron acceptor와 경쟁한다는 가설을 뒷받침한다. 호기성 박테리아에 의해서도 실험조건하에서 상당량(25∼30%)의 사염화탄소가 제거되었다. Electron acceptor의 공급중단에는 영향을 받지 않았다. 그러나 사염화탄소의 제거와 함께 클로로폼이 형성되므로써 사염화탄소의 환원분해가 호기성 상태에서도 진행될 수 있음을 보여 주었다.

  • PDF

$SF_6$ 가스의 전자에너지 분포함수에 관한 연구 (A study on the electron energy diffusion function of the sulphur hexaflouride)

  • 김상남;유회영;서상현;박동화;하성철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.134-139
    • /
    • 1996
  • The electron energy distributions function were analysed in sulphur hexaflouride at E/N : 500~800(Td) for a case of non-equilibrium ion in the mean electron energy. This paper describes the electron transport characteristics in SF$_{6}$ gas calculated for range of E/N values from 150~800(Td) by the Monte Carlo simulation and Boltzmann equation method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters. The results gained that the value of an electron swarm parameter such as the electron drift velocity, the electron ionization or attachment coefficients, longitudinal and transverse diffusion coefficients agree with the experimental and theoretical for a range of E/N. The properties of electron avalanches in an electron energy non-equilibrium region.n.

  • PDF