• 제목/요약/키워드: Electromagnetic surface current meter

검색결과 7건 처리시간 0.018초

표면영상유속계(SIV)를 이용한 홍수유출량 측정 (Flood Runoff Measurements using Surface Image Velocimetry)

  • 김용석;양성기;류권규;김동수
    • 한국환경과학회지
    • /
    • 제22권5호
    • /
    • pp.581-589
    • /
    • 2013
  • Surface Image Velocimetry(SIV) is an instrument to measure water surface velocity by using image processing techniques. Since SIV is a non-contact type measurement method, it is very effective and useful to measure water surface velocity for steep mountainous streams, such as streams in Jeju island. In the present study, a surface imaging velocimetry system was used to calculate the flow rate for flood event due to a typhoon. At the same time, two types of electromagnetic surface velocimetries (electromagnetic surface current meter and Kalesto) were used to observe flow velocities and compare the accuracies of each instrument. The comparison showed that for velocity distributions root mean square error(RMSE) was 0.33 and R-squared was 0.72. For discharge measurements, root mean square error(RMSE) reached 6.04 and R-squared did 0.92. It means that surface image velocimetry could be used as an alternative method for electromagnetic surface velocimetries in measuring flood discharge.

유량측정 기기별 측정성과에 대한 실험적 비교분석 (Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters)

  • 이재혁;이석호;정성원;김태웅
    • 한국습지학회지
    • /
    • 제12권1호
    • /
    • pp.95-103
    • /
    • 2010
  • 유량자료는 물의 순환과정을 규명하고 효율적인 수자원 개발 및 이수 치수 계획 등에 매우 귀중하게 이용된다. 그러나 이러한 유량자료를 확보하는데 많은 시간과 경비 등이 요구되기 때문에 주요 수위에서 유량자료는 수위-유량관계곡선식(Stage-Discharge Curve)을 개발하여 유량을 산정하고 있다. 따라서 수위-유량관계곡선식의 신뢰도는 유량자료의 품질에 절대적인 영향을 미치는 요인으로 작용된다. 수문학을 전공하고 연구하는 많은 학자들은 고품질의 유량자료를 생산하여 신뢰성 있는 곡선식을 개발하고자 유량측정 방법과 기준, 장비개발 및 개량 등에 관한 연구를 수행하고 있다. 현재 국내에서는 다양한 유량측정기기를 사용하여 유량자료를 생산하고 활용하고 있으나, 측정기기별 정확도 및 실험적 측정성과에 대한 연구자료가 미흡한 실정이다. 본 연구에서는 규격화된 콘크리트 수로에 일정한 유량을 흘려보내는 조건에서 다양한 측정기기를 이용하여 유속을 측정하였다. 그리고 이 측정성과를 이용하여 유량을 산정하고 비교분석하였다. 실험을 위해서 국내에서 일반적으로 사용되고 있는 측정기기로 프라이스 유속계(USGS Type AA Current Meter), 휴대용 유량계(Flow Meter), 초음파식 디지털 유속계(ADC), C2 유속계(C2 Small Current Meter), 플로우 트렉커(Flow Tracker), 마그네틱 유속계(Electromagnetic Current Meter) 등의 장비를 사용하여 유량을 산정하였으며, 각 기기별 산정된 유량을 비교 분석 하였다. 비교검토에 적용하고자 측정한 수심으로는 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m의 왕복측정 6-Case로 진행이 되었으며, 신뢰성과 정확도를 높이기 위해 도섭법으로 수면에서 0.6d 지점의 유량측정방법(1점법)을 적용하였다. USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter는 유속측정기기의 검교정을 받았으므로 다른 실험유량측정치의 비교를 위한 기준값으로 사용하였다. 따라서 국내에서 널리 사용되는 측정기기(USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter, Flow Tracker, Electromagnetic Current meter)별 검토 결과 평균유량 및 평균유속에 있어 프라이스 유속계를 기준으로 마그네틱 유속계 $\pm$ 10 % 이상, 플로우 트렉커 $\pm$ 10 % 미만, 휴대용 유량계, 초음파식 디지털 유속계 및 C2 유속계는 $\pm$ 5 % 미만의 차이가 있음을 확인할 수 있었다.

전자파와 수표면 영상을 이용한 산지하천 홍수유량 및 유속 계측 비교 연구 (Comparison of Flood Discharge and Velocity Measurements in a Mountain Stream Using Electromagnetic Wave and Surface Image)

  • 양성기;김동수;류권규;강명수;정우열;이준호;김용석;유호준
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.739-747
    • /
    • 2012
  • Due to the difficulties for measuring flood discharge in the dangerous field conditions, conventional instruments with relatively low accuracy such as float still have been widely utilized for the field survey. It is also limited to use simple stage-discharge relationship for assessment of the flood discharge, since the stage-discharge relationship during the flood becomes complicated loop shape. In recent years, various non-intrusive velocity measurement techniques such as electromagnetic wave or surface images have been developed, which is quite adequate for the flood discharge measurements. However, these new non-intrusive techniques have little tested in the flood condition, though they promised efficiency and accuracy. Throughout the field observations, we evaluated the validity of these techniques by comparing discharge and velocity measurements acquired concurrently during the flood in a mountain stream. As a result, the flood discharge measurements between electromagnetic wave and surface image processing techniques showed high positive relationship, but velocities did not matched very well particularly for the high current speed more 3 m/s. Therefore, it should be noted here that special cares are required when the velocity measurements by those two different techniques are used, for instance, for the validation of the numerical models. In addition, authors assured that, for the more accurate flood discharge measurements, velocity observation as well as stage height is strongly necessary owing that the unsteady flow occurs during the flood.

현장유출영상을 활용한 표면영상유속계(SIV)의 상관계수 분석 (Analysis on Correlation Coefficient of Surface Image Velocimeter (SIV) Using On-site Runoff Image)

  • 김용석;양성기;김동수;김서준
    • 한국환경과학회지
    • /
    • 제24권4호
    • /
    • pp.403-414
    • /
    • 2015
  • This study is daytime and nighttime runoff image data caused by heavy rain on May 27, 2013 at Oedo Water Treatment Plant of Oedo-Stream, Jeju to compute runoff by applying Surface image velocimeter (SIV) and analyzing correlation according to current. At the same time, current was comparatively analyzed using ADCP observation data and fixed electromagnetic surface current meter (Kalesto) observed at the runoff site. As a result of comparison on resolutions of daytime and nighttime runoff images collected, correlation coefficient corresponding to the range of 0.6~0.7 was 6.8% higher for nighttime runoff image compared to daytime runoff image. On the contrary, correlation coefficient corresponding to the range of 0.9~1.0 was 17% lower. This result implies that nighttime runoff image has lower image quality than daytime runoff image. In the process of computing current using SIV, a rational filtering process for correlation coefficient is needed according to images obtained.

재난감시용 하천 CCTV를 활용한 홍수유출량 산정 (Flood Runoff Calculation using Disaster Monitoring CCTV System)

  • 김용석;양성기;류권규;김동수
    • 한국환경과학회지
    • /
    • 제23권4호
    • /
    • pp.571-584
    • /
    • 2014
  • The present study aims to apply a surface image velocimetry(SIV) system to video images captured with CCTV and estimate the flood discharge. The CCTV was installed at the Hancheon Bridge of the Han Cheon in Jeju Island for disaster surveillance, and seven flood events occurred in 2012 were used. During the image analyses, input parameters, interrogation areas and searching areas were determined with proper calibration procedures. To check for accuracy and applicability of SIV, the velocities and flood discharges estimated by SIV were compared with the measured ones by an electromagnetic surface velocimeter, Kalisto. The comparison results showed fairly good agreements. The RMSE(Root Mean Square Error) values between two instruments showed a range of 4.13 and 14.2, and the determination coefficients reached 0.75 through 0.85. It means that the SIV could be used as a good alternative method for other traditional velocity measuring instruments in measuring flood discharges.

LSPIV를 이용한 표면유속 측정기법의 검증 및 적용 (Verification and Application of Surface-Velocity Measurement Method Using LSPIV)

  • 김영근;노영신;윤병만
    • 한국수자원학회논문집
    • /
    • 제37권2호
    • /
    • pp.155-161
    • /
    • 2004
  • 본 연구에서는 LSPIV기법의 효율성과 적용성을 검증하기 위해 유속검정용 전동기계를 이용한 검증실험을 통하여 LSPIV기법을 검증하였다. 검증을 실시한 후에 LSPIV기법을 실제하천에 적용하였다 대상하천으로는 경안천의 지류인 능원천과 곤지암천을 선택하였으며, 3차원 유속계 및 기존의 표면유속 측정에 사용해 왔던 전자파 표면유속계의 측정결과와 비교하였다. 본 연구를 통해 나타난 결과를 살펴보면 검증실험에 사용된 전동차의 결과값과 비교했을 때 LSPIV기법의 측정값은 5%이내의 오차로 잘 일치하는 경향을 나타냈으며, 실제하천에 적용하여 기존의 측정장치와 비교하였을 때에도 최대 8% 이내의 오차로 잘 일치하였다.

레이다 센서 기반 실시간 유량 측정 및 홍수 예측 시스템 연구 (Research on Real-time Flow Rate Measurement and Flood Forecast System Based on Radar Sensors)

  • 이영우;석혁준;정기헌;나국진;이승규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.288-290
    • /
    • 2022
  • 최근 정부는 SOC디지털화 계획의 하나로 스마트 물관리 및 홍수 예방을 위해 배수시설 자동·원격제어체계를 국가하천 57%에 도입(1,800억원)하고 실시간 모니터링체계(300억원)를 구축하며, 댐 11개소에 빅데이터를 기반으로 한 스마트 댐 안전관리 체계(150억원)를 마련할 계획입니다. 이러한 스마트 물관리 및 홍수 예방을 위해서는 하천의 실시간 유속 측정을 통해 중간단면법을 적용하여 유량을 정확히 계산할 수 있는 시스템의 연구가 필요합니다. 이러한 시스템의 구현과 정확도를 높이기 위해서 가장 중요한 것은 실시간 유속 측정의 정확도를 확보하는 것입니다. 현재 실시간 유속 측정을 위해 미국, 유럽 등의 전자파 표면 유속 측정용 레이다 센서를 도입하여 시스템에 적용하고 있으나 고가의 가격, 유속 측정 범위의 한계 및 기술 지원 미흡 등의 문제로 인해 시스템의 개선 요구가 지속되고 있는 상황입니다. 따라서 실시간 유속 측정을 위한 전자파 표면 유속 측정용 레이다 센서를 자체 개발하여 개선된 유량 측정 및 홍수 예측 시스템을 제시하고자 합니다.

  • PDF