Stress analysis of the KSTAR vacuum vessel under thermal and electromagnetic loads (KSTAR 진공용기 열 및 전자기력 하중에 의한 응력해석)

  • Cho, S.;Kim, J.B.;Her, N.I.;Im, K.H.;Sa, J.W.;Yu, I.K.;Kim, Y.C.;Do, C.J.;Kwon, M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.325-330
    • /
    • 2001
  • One of the principal components of the KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak structure is the vacuum vessel, which acts as the high vacuum boundary for the plasma and also provides the structural support for internal components. Hyundai Heavy Industries Inc. has performed the engineering design of the vacuum vessel. Here the overall configuration of the KSTAR vacuum vessel was briefly described and then the design methodology and the analysis results were presented. The vacuum vessel consists of double walls, several ports, leaf spring style supports. Double walls are separated by reinforcing ribs and filled with baking/shielding water. The overall external dimensions of the main body are 3.39 m high, 1.11 m inner radius, 2.99 m outer radius, and made of SA240-316LN. The vacuum vessel was designed to be capable of achieving the base pressure of $1\times10^{-8}$ Torr, and also to be structurally capable of sustaining the vacuum pressure, the electromagnetic and thermal loads during plasma disruption and bakeout, respectively. The vacuum vessel will be baked out maximum $150^{\circ}C$ by hot pressurized water through the channels formed between double walls and the reinforcing ribs. A 3-D temperature distribution and the resulting thermal loads in the vessel were calculated during bakeout. It was found that the vacuum vessel and its supports were structurally rigid based on the thermal stress analysis. The maximum electromagnetic loads on the vacuum vessel induced by eddy and halo currents resulting from the engineering plasma radial and vertical disruption scenarios have been estimated. The stress analyses have been performed based on these electromagnetic loads and the resulting stresses at he critical locations of the vacuum vessel were within the allowable stresses.

  • PDF

Design of a Planar Log-Spiral Antenna for Testing Plane-Wave Shielding Effectiveness (평면파 차폐효과 시험용 평판형 로그 스파이럴 안테나 설계)

  • Chung, Yeon-Choon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.762-767
    • /
    • 2019
  • The plane-wave shielding effectiveness is typically measured for horizontal and vertical polarizations using a linearly polarized antenna. However, this typical measurement method results in big evaluation fees due to very long measurement time as well as huge idle space for maintenance, these problems is more severe especially in large shielded enclosures such as EMP protection facilities to be built in indoor buildings and underground. This paper describes the design and fabrication process and results of a planar log-spiral antenna applicable to the evaluation of the electromagnetic shielding effectiveness of a large EMP protection facility. Since the proposed antenna has a circular polarization, there is no need to separately measure the horizontal and vertical polarizations. Therefore, the measurement time can be shortened by more than 1/2, and further, its small volume with a planar structure can reduce greatly idle space required for the maintenance.

A Study on the Design of High-Voltage Connector for Green Car using FEM (유한요소법을 이용한 친환경 자동차용 고전압 커넥터 설계에 관한 연구)

  • Kim, Sung-Woong;Choi, Jung-Wook;Kim, Hyeung-Rak;Kwon, Young-Seok;Kang, Nam-Jin;Choi, Kyung-Seok;Park, Hyung-Pil;Cha, Baeg-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.716-723
    • /
    • 2011
  • The battery capacity of electric/hybrid vehicle is much larger than present automobile. For that reason, the connector of Green Car should be designed to transmit the high-electric voltage. In addition, the electromagnetic wave should be shielded to protect communication and signal circuits. In this study, shielding performance of the connector was analyzed through electromagnetic shield analysis, and a connector of Green Car was designed using thermoelectrical analysis, which is capable of transmitting the high-electric power. In the design of connector structure, the improved stability and workability was considered.

An Optimal Rescheduling of Power Generation to Constrain the EM Field Emitted from Power Transmission Lines (송전선로에서 발생하는 전자계 제약을 고려한 발전력의 최적 재분배)

  • Kim, Jong-Hyeong;Sin, Myeong-Cheol;Ra, Wan-Su;Park, Il-Han
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.10
    • /
    • pp.464-471
    • /
    • 2001
  • Power utilities must satisfy both supplying high quality power economically and reducing EMF levels. In general, in order to reduce EMF levels from transmission line, it is effective to install shielding wires, configure wires with minimal space or modify structure of other conductors, etc., but these techniques require much cost and time. To some extent, the EMF levels associated with critical transmission lines can be reduced by redistributing the scheduled power generation, since it can change the power flows. There this technique can be readily applied without modifying other structures. This paper considers the OPF(Optimal Power Flow) with the EMF constraints in transmission lines to determine the power generation redistributions and demonstrates numerically the effectiveness of the approach.

  • PDF

Evaluation of physical properties of Zn-Al metal coating according to arc metal spray surface treatment method (아크 금속 용사 표면 처리 방법에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가)

  • Jang, Jong-Min;Kim, Yeung-Kwan;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.89-90
    • /
    • 2022
  • Arc metal spraying is a widely used method for improving the performance of construction structures such as corrosion resistance and electromagnetic wave shielding. However, when arc metal spraying is applied to a concrete structure, adhesion performance may deteriorate. Therefore, the effect of each surface treatment method on the physical properties between the arc metal spray coating and concrete was reviewed by evaluating the deposition efficiency and adhesion performance according to the arc metal spray surface treatment method (surface reinforcing agent, roughening agent, and sealing agent). As a result, it is suggested as an optimal surface treatment condition to induce non-interface failure by using a roughening agent and to improve the properties of concrete and metal coatings by applying a surface reinforcing agent and sealing agent.

  • PDF

Analysis of Penetration Phenomenon of High Altitude Electromagnetic Pulse into Buried Facilities with Various Moisture Content and Depth (수분 함유량 및 지하 구조물 깊이에 따른 고고도 전자기파(HEMP) 투과 현상 분석)

  • Kang, Hee-Do;Oh, Il-Young;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.644-653
    • /
    • 2013
  • In this paper, a formulation for obliquely incident electromagnetic wave has been presented for an analysis of highpower electromagnetic pulse penetration into multilayered dispersive media. Based on generalized models of measured dielectric constants and propagation channels reflecting the Earth's general features, the propagation phenomenon of the obliquely incident early-time(E1) high altitude electromagnetic pulse(HEMP) is analyzed. In addition, the polarization and critical angle are also considered. It is found that the total reflection occurs at an incident angle of about 38 degrees at the soil-rock interface, and that the parallel-polarized E1 HEMP penetrates better than the perpendicular-polarized one. The peak level of the penetrating electric field is found to be 5.6 kV/m at normal incidence, regardless of the type of polarization, and E1 HEMP is greatly reduced near the critical angle. Moreover, the penetrating E1 HEMP is analyzed as a variation of moisture content and depth of materials, resulting E1 HEMP could be useful in determining the levels of shielding required for buried facilities.

Compensation Method of Parameters to Evaluate a Sheilding Coefficient of Electromagnetic Induction Voltage (전자유도전압 차폐계수 산정을 위한 파라미터 보정 방법)

  • Lee, Sangmu;Choi, Mun Hwan;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.503-506
    • /
    • 2013
  • The shielding coefficient of a conductive length structure is calculated by a ratio of induced voltage with that structure to without that structure. The environments are different between with a structure and without a structure. Beside the corresponding structure, all the parameters related to induced voltage should be normalized to a presumable same environment conditions. Basically each parameter must be compensated, which is a bottom-up type method. In this case, some parameter is not possible to be so because of its unknowing function. Then as a calculated voltage already has all characteristics of parameters, seeking a ratio of calculated induction voltages themselves will include the compensation of all parameters automatically. This is a top-down method.

  • PDF

Effects of Sputtering pressure on preferred Orientation of Shielding NbTi Thin Film by RF Magnetron Sputtering (RF 마그네트론 스퍼터링법으로 제조된 차폐용 NbTi박막의 우선방향에 미치는 스퍼터링 압력의 영향)

  • Kim, Bong-Seo;Woo, Byung-Chul;Byun, Woo-Bong;Lee, Hee-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1098-1101
    • /
    • 1995
  • NbTi thin films were prepared on Si wafer and Cu substrate by rf magnetron sputtering in the range of sputtering pressure $3{\times}10^{-2}$torr to $3{\times}10^{-4}$torr at room temperature. The influence of sputtering pressure and substrate type on crystallographic orientation and morphology of NbTi thin films was investigated by using X-ray diffraction(XRD) and scanning electron microscopy(SEM), respectively. And the effect of crystallographic orientation and morphology of NbTi film on electromagnetic behaviors was estimated by measuring critical current in various applied magnetic field. The film morphology changed from porous structure consisting of tapered crystallites to densely deposited film decreasing with sputtering pressure. The change of crystallographic orientation with the sputtering pressure and rf power was calculated from the texture coefficient of(002) plane based on XRD patterns. It was found that a change of texture coefficient of(002) plane increased with decreasing sputtering pressure. From observation of critical current in various applied magnetic field, we have identified that the change of critical current abruptly decrease applying with magnetic field and NbTi film produced at high sputtering pressure does not exhibit superconductivity but at low sputtering pressure shows superconductivity.

  • PDF

Sound Absorption and Physical Properties of Carbonized Fiberboards with Three Different Densities

  • Lee, Min;Park, Sang-Bum;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.555-562
    • /
    • 2014
  • Characteristics of carbonized fiberboard such as chemical materials absorption, electromagnetic shielding, and electrical and mechanical performance were determined in previous studies. The carbonized board therefore confirmed that having excellent abilities of these characteristics. In this study, the effect of density on physical properties and sound absorption properties of carbonized fiberboards at $800^{\circ}C$ were investigated for the potential use of carbonized fiberboards as a replacement of conventional sound absorbing material. The thickness of fiberboards after carbonization was reduced 49.9%, 40.7%, and 43.3% in low density fiberboard (LDF), medium density fiberboard (MDF), and high density fiberboard (HDF), respectively. Based on SEM images, porosity of carbonized fiberboard increased by carbonization due to removing adhesives. Moreover, carbonization did not destroy structure of wood fiber based on SEM results. Carbonization process influenced contraction of fiberboard. The sound absorption coefficient of carbonized low density fiberboard (c-LDF) was higher than those of carbonized medium density fiberboard (c-MDF) and carbonized high density fiberboard (c-HDF). This result was similar with original fiberboards, which indicated sound absorbing ability was not significantly changed by carbonization compared to that of original fiberboards. Therefore, the sound absorbing coefficient may depend on source, texture, and density of fiberboard rather than carbonization.

Optical and structural properties of metal-dielectric near-infrared cutoff filters for plasma display panel application

  • Lee, Jang-Hoon;Lee, Kwang-Su;Hwangbo, Chang-Kwon
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.88-91
    • /
    • 2003
  • Electromagnetic interference shielding and near-infrared cutoff filters for plasma display panel application were designed and fabricated by radio frequency magnetron sputtering. Three types of the filters were prepared: the basic structure of type A consisted of [$TiO_2$ Ti Ag $TiO_2$]; type B, of [$TiO_2$ ITO Ag $TiO_2$]; type C, of [$TiO_2$ ITO Ag ITO $TiO_2$]. Ti and ITO layers deposited on Ag layers were employed as barriers to prevent the oxidation and the diffusion of Ag film into the adjacent oxide layers. Optical, electrical, chemical, and structural properties were investigated, and the result shows that the filters with the ITO barrier layers provided an enhancement in transmittance in the visible owing to a lower absorption of ITO layers than Ti layers. Type C filter showed better optical and electrical performances and smoother surface roughness than Type B and C filters: the average sheet resistance was as low as 1.51 $\Omega\Box$ (where $\square$ stands for a square film), the peak transmittance in the visible was as high as 78.2 %, and the average surface roughness was 1.48 nm.