• Title/Summary/Keyword: Electromagnetic field analysis

Search Result 790, Processing Time 0.024 seconds

Development of Program Package for Electromagnetic Field Analysis (전자장 해석 프로그램 개발)

  • Lee, Jung-Jong;Hong, Jung-Pyo;Lee, Ju;Kim, Wa-Sung;Lee, Hee-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.909-911
    • /
    • 2000
  • This paper introduce of program package for the numerical analysis of Electromagnetic field analysis using Finite Element Method, called Electro Magnetic Field(EMF). This software tool is developed by Changwon Nat'l Univ. cooperative with Hanyang Univ. and produced on a commercial scale. EMF has a simple, easy to use graphical interface which steps user through th problem setup, high accurate solution, and fast computation.

  • PDF

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

A Study on Magnetic Field Distribution Characteristics for Remote Field Area (리모트 필드 영역에서의 자계 분포특성에 관한 연구)

  • Kim, S.K.;Lee, E.U.;Lim, S.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.312-314
    • /
    • 2000
  • The electric wave propagation characteristics of electromagnetic field by induction current shows a nonlinear distinction in the metal but linear on air. This paper is written about the magnetic transmission distinction in the metalic tube, which wrapped the center axis by the same direction. The electromagnetic field made by the transmission signal is transferred from the transmission coil area toward the receiving coil by the magnetic diffusion. So, it is different magnetic flux around the coil with one in the remote field area. Analyzing such a complex magnetic characteristic, we verified this theory by the vector analysis and presented eddy current mechanism and analytical model about magnetic distribution in the remote field area. This magnetic distribution rate in metal body will be very useful in the nondestructive inspection of the eddy current in remote field which is recently rising as a new technology.

  • PDF

RF Heating of Implants in MRI: Electromagnetic Analysis and Solutions

  • Cho, Youngdae;Yoo, Hyoungsuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 2020
  • When a patient takes an MRI scan, the patient has a risk of unexpected injuries due to the intensive electromagnetic (EM) field. Among the injuries, the tissue heating by the time-varying EM field is one of the main issues. Since an implanted artificial structure with a conductive material aggravates the heating effect, lots of studies have been conducted to investigate the effect around the implants. In this review article, a mechanism of RF heating around the implants and related studies are comprehensively investigated.

Analysis of Wireless Power Transfer Characteristics for Multiple Receivers by Time Sharing Technique

  • Park, Jong-Min;Nam, Sang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.183-185
    • /
    • 2011
  • A multiple charging method for a wireless power transfer system (WPTS) in the near-field region is proposed. We analyzed the frequency characteristics of multiple receivers in the near-field region. The results suggested that the time division WPTS can achieve efficient and equal power transmission at multiple receivers. We conclude that this system has an advantage for charging multiple receivers.

Design and Near-Field Analysis of X-Band Linear/Circular Polarizer (X-밴드 선형/원형 편파 변환기의 설계 및 근거리장 해석)

  • 서창용;정명수;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.8
    • /
    • pp.801-808
    • /
    • 2004
  • In this paper, we proposed the grating parallel plate waveguide structure for converting a linearly polarized wave to a circularly polarized wave. For the design of the polarizer, the moment method and Floquet's theorem are applied under two assumptions that the incident wave is a plane wave and the structure is infinitely periodic. In order for the more precise design, we performed the near-field analysis for the finite polarizer structure using MATLAB. By comparing with the measured results obtained by the near-field arrangement, we verified the correctness of our near-field analysis. By taking the ideal assumptions considered in the initial design procedure into account, newly designed modified dimensions for the polarizer was suggested which give improved performance.

The Analysis of Effect for Photocoupler by Narrow-Band High-Power Electromagnetic Wave (협대역 고출력 전자기파에 의한 포토커플러 영향 분석)

  • Lee, Sung-Woo;Huh, Chang-Su;Seo, Chang-Su;Jin, In-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • This study analyzed the change of electrical characteristics of a photocoupler when a narrow-band electromagnetic wave was combined with the photocoupler. A magnetron (3 kW, 2.45 GHz) was used as the narrow-band electromagnetic source. The EUT was Photocoupler (6N139) and the input signal was divided into two types: a square pulse and the second signal is 0 V. The malfunction of the photocoupler was confirmed by monitoring the variation in the output voltage of the photocoupler. As a result of the experiment, changes in the malfunctioning was observed as the electric field was increased. There are three types of malfunction modes: delay, output voltage off, and fluctuation. Bit errors were analyzed to verify the electrical characteristics of the photocoupler by narrow-band electromagnetic waves. The result of this study can be used as basic data for the effect analysis of photocoupler protection and impact analysis of high-power electromagnetic waves.